The DOI matches its Crossref record.
A Microfluidic Approach for Screening Submicroliter Volumes against Multiple Reagents by Using Preformed Arrays of Nanoliter Plugs in a Three‐Phase Liquid/Liquid/Gas Flow
Open accessAbstract
Plugging a gap in screening: Arrays of nanoliter-sized plugs of different compositions can be preformed in a three-phase liquid/liquid/gas flow. The arrays can be transported into a microfluidic channel to test against a target (see schematic representation), as demonstrated in protein crystallization and an enzymatic assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationLab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Transition from squeezing to dripping in a microfluidic T-shaped junction
DE MENECH, M., GARSTECKI, P., JOUSSE, F., & STONE, H. A. (2008) · Journal of Fluid Mechanics · doi:10.1017/s002211200700910x · Cited by 728
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Production of uniform droplets using membrane, microchannel and microfluidic emulsification devices
Vladisavljević, G. T., Kobayashi, I., & Nakajima, M. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0948-0 · Cited by 374
Pillar-induced droplet merging in microfluidic circuits
Niu, X., Gulati, S., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b813325e · Cited by 374
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citationMicrofluidics-based systems biology
Breslauer, D. N., Lee, P. J., & Lee, L. P. (2006) · Molecular BioSystems · doi:10.1039/b515632g · Cited by 303
Electrocoalescence of drops synchronized by size-dependent flow in microfluidic channels
Ahn, K., Agresti, J., Chong, H., Marquez, M., & Weitz, D. A. (2006) · Applied Physics Letters · doi:10.1063/1.2218058 · Cited by 300
Wang, J., Wang, J., & Han, J. (2011) · Small · doi:10.1002/smll.201001913 · Cited by 293
Fang, X., Liu, Y., Kong, J., & Jiang, X. (2010) · Analytical Chemistry · doi:10.1021/ac1000652 · Cited by 292
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
Self-citation
Metadata
- Authors
- Zheng, B., & Ismagilov, R. F.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2005-04-21
- Volume
- 44
- Issue
- 17
- Pages
- 2520-2523
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2103169680
- Cited by
- 232
- References
- 0
- FWCI
- 17.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.