The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Rational Design of “Turn‐On” Allosteric DNAzyme Catalytic Beacons for Aqueous Mercury Ions with Ultrahigh Sensitivity and Selectivity
Open accessAbstract
The mercury is rising: A DNAzyme with several thymine residues located close to the catalytic site is rendered inactive. However, thymine–Hg2+–thymine interactions transform the DNAzyme into an active enzyme. When fluorophore/quencher pairs are attached, the DNAzyme can be converted into a highly sensitive and selective mercury sensor with a detection limit of 2.4 nM and a greater than 100 000-fold selectivity over other metal ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404
The Chemical Form of Mercury in Fish
Harris, H. H., Pickering, I. J., & George, G. N. (2003) · Science · doi:10.1126/science.1085941 · Cited by 1,353
A Colorimetric Lead Biosensor Using DNAzyme-Directed Assembly of Gold Nanoparticles
Liu, J., & Lu, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034775u · Cited by 1,347
Self-citationLee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700269 · Cited by 1,308
Highly Selective Oligonucleotide‐Based Sensor for Mercury(II) in Aqueous Solutions
Ono, A., & Togashi, H. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200454172 · Cited by 1,162
MercuryII-Mediated Formation of Thymine−HgII−Thymine Base Pairs in DNA Duplexes
Miyake, Y., Togashi, H., Tashiro, M., Yamaguchi, H., Oda, S., Kudo, M., Tanaka, Y., Kondo, Y., Sawa, R., Fujimoto, T., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056354d · Cited by 1,079
Yang, Y.-K., Yook, K.-J., & Tae, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054855t · Cited by 1,044
A Highly Sensitive and Selective Catalytic DNA Biosensor for Lead Ions
Li, J., & Lu, Y. (2000) · Journal of the American Chemical Society · doi:10.1021/ja0021316 · Cited by 704
Self-citation15N−15N J-Coupling Across HgII: Direct Observation of HgII-Mediated T−T Base Pairs in a DNA Duplex
Tanaka, Y., Oda, S., Yamaguchi, H., Kondo, Y., Kojima, C., & Ono, A. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065552h · Cited by 541
Liu, J., Brown, A. K., Meng, X., Cropek, D. M., Istok, J. D., Watson, D. B., & Lu, Y. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607875104 · Cited by 523
Self-citationDirected Evolution of Nucleic Acid Enzymes
Joyce, G. F. (2004) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.73.011303.073717 · Cited by 515
In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe
Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065114a · Cited by 509
Turn-On and Ratiometric Mercury Sensing in Water with a Red-Emitting Probe
Nolan, E. M., & Lippard, S. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068879r · Cited by 428
A selective fluorescent ratiometric chemodosimeter for mercury ion
Liu, B., & Tian, H. (2005) · Chemical Communications · doi:10.1039/b501913c · Cited by 381
Breaker, R. R. (1997) · Nature Biotechnology · doi:10.1038/nbt0597-427 · Cited by 343
Liu, X., Tang, Y., Wang, L., Zhang, J., Song, S., Fan, C., & Wang, S. (2007) · Advanced Materials · doi:10.1002/adma.200602578 · Cited by 338
Engineering precision RNA molecular switches
Soukup, G. A., & Breaker, R. R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.7.3584 · Cited by 333
In vitro selection, characterization, and application of deoxyribozymes that cleave RNA
Silverman, S. K. (2005) · Nucleic Acids Research · doi:10.1093/nar/gki930 · Cited by 303
Wegner, S. V., Okesli, A., Chen, P., & He, C. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068342d · Cited by 271
Engineered allosteric ribozymes as biosensor components
Breaker, R. R. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00281-1 · Cited by 266
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie · doi:10.1002/ange.200700269 · Cited by 265
Wang, J., & Qian, X. (2006) · Organic Letters · doi:10.1021/ol061297u · Cited by 222
Improving Fluorescent DNAzyme Biosensors by Combining Inter- and Intramolecular Quenchers
Liu, J., & Lu, Y. (2003) · Analytical Chemistry · doi:10.1021/ac034924r · Cited by 199
Self-citationNew Transition-Metal-Dependent DNAzymes as Efficient Endonucleases and as Selective Metal Biosensors
Lu, Y. (2002) · Chemistry - A European Journal · doi:10.1002/1521-3765(20021018)8:20<4588::aid-chem4588>3.0.co;2-q · Cited by 186
Self-citationDNAzymes: From Creation In Vitro to Application In Vivo
Achenbach, J., Chiuman, W., Cruz, R., & Li, Y. (2004) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201043376751 · Cited by 182
Chiuman, W., & Li, Y. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkl1056 · Cited by 62
Self-Assembled Monolayers of Thiol-End-Labeled DNA at Mercury Electrodes
Ostatná, V., & Paleček, E. (2006) · Langmuir · doi:10.1021/la061424v · Cited by 45
Cited by
Tools and Tactics for the Optical Detection of Mercuric Ion
Nolan, E. M., & Lippard, S. J. (2008) · Chemical Reviews · doi:10.1021/cr068000q · Cited by 2,345
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Self-citationZhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Self-citationA Ratiometric Fluorescent Probe Based on FRET for Imaging Hg 2+ Ions in Living Cells
Zhang, X., Xiao, Y., & Qian, X. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803246 · Cited by 800
Enzyme Mimics Based Upon Supramolecular Coordination Chemistry
Wiester, M. J., Ulmann, P. A., & Mirkin, C. A. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201000380 · Cited by 778
Metadata
- Authors
- Liu, J., & Lu, Y.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2007-09-28
- Volume
- 46
- Issue
- 40
- Pages
- 7587-7590
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2120749428
- Cited by
- 593
- References
- 27
- FWCI
- 15.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.