The DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Semiconductor Gas Sensors: Dry Synthesis and Application
Abstract
Since the development of the first chemoresistive metal oxide based gas sensors, transducers with innovative properties have been prepared by a variety of wet‐ and dry‐deposition methods. Among these, direct assembly of nanostructured films from the gas phase promises simple fabrication and control and with the appropriate synthesis and deposition methods nm to μm thick films, can be prepared. Dense structures are achieved by tuning chemical or vapor deposition methods whereas particulate films are obtained by deposition of airborne, mono‐ or polydisperse, aggregated or agglomerated nanoparticles. Innovative materials in non‐equilibrium or sub‐stoichiometric states are captured by rapid cooling during their synthesis. This Review presents some of the most common chemical and vapor‐deposition methods for the synthesis of semiconductor metal oxide based detectors for chemical gas sensors. In addition, the synthesis of highly porous films by novel aerosol methods is discussed. A direct comparison of structural and chemical properties with sensing performance is given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-cost, high-efficiency solar cell based on dye-sensitized colloidal TiO2 films
O'Regan, B., & Grätzel, M. (1991) · Nature · doi:10.1038/353737a0 · Cited by 28,599
Titanium Dioxide Nanomaterials: Synthesis, Properties, Modifications, and Applications
Chen, X., & Mao, S. S. (2007) · Chemical Reviews · doi:10.1021/cr0500535 · Cited by 10,688
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
Gas sensors using hierarchical and hollow oxide nanostructures: Overview
Lee, J.-H. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.026 · Cited by 1,493
A New Detector for Gaseous Components Using Semiconductive Thin Films.
Seiyama, T., Kato, A., Fujiishi, K., & Nagatani, M. (1962) · Analytical Chemistry · doi:10.1021/ac60191a001 · Cited by 1,486
Grain size effects on gas sensitivity of porous SnO2-based elements
Xu, C., Tamaki, J., Miura, N., & Yamazoe, N. (1991) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(91)80207-z · Cited by 1,426
Metal and Metal Oxide Nanoparticles in Chemiresistors: Does the Nanoscale Matter?
Franke, M. E., Koplin, T., & Simon, U. (2005) · Small · doi:10.1002/smll.200500261 · Cited by 1,376
Applications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
High-performance electronics using dense, perfectly aligned arrays of single-walled carbon nanotubes
Kang, S. J., Kocabas, C., Ozel, T., Shim, M., Pimparkar, N., Alam, M. A., Rotkin, S. V., & Rogers, J. A. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.77 · Cited by 1,088
Cited by
Metal Oxide Nanostructures and Their Gas Sensing Properties: A Review
Sun, Y.-F., Liu, S.-B., Meng, F.-L., Liu, J.-Y., Jin, Z., Kong, L.-T., & Liu, J.-H. (2012) · Sensors · doi:10.3390/s120302610 · Cited by 1,218
One-Dimensional Titanium Dioxide Nanomaterials: Nanotubes
Lee, K., Mazare, A., & Schmuki, P. (2014) · Chemical Reviews · doi:10.1021/cr500061m · Cited by 1,185
Gas sensing mechanisms of metal oxide semiconductors: a focus review
Ji, H., Zeng, W., & Li, Y. (2019) · Nanoscale · doi:10.1039/c9nr07699a · Cited by 1,108
Recent Developments in p‐Type Oxide Semiconductor Materials and Devices
Wang, Z., Nayak, P. K., Caraveo‐Frescas, J. A., & Alshareef, H. N. (2016) · Advanced Materials · doi:10.1002/adma.201503080 · Cited by 779
Recent Progress on the Development of Chemosensors for Gases
Zhou, X., Lee, S., Xu, Z., & Yoon, J. (2015) · Chemical Reviews · doi:10.1021/cr500567r · Cited by 777
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Mesoporous materials as gas sensors
Wagner, T., Haffer, S., Weinberger, C., Klaus, D., & Tiemann, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35379b · Cited by 629
Atomic Layer Deposition of Nanostructured Materials for Energy and Environmental Applications
Marichy, C., Bechelany, M., & Pinna, N. (2012) · Advanced Materials · doi:10.1002/adma.201104129 · Cited by 591
Metal oxide composites in conductometric gas sensors: Achievements and challenges
Korotcenkov, G., & Cho, B. K. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.12.117 · Cited by 547
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Self-citationRecent developments in 2D layered inorganic nanomaterials for sensing
Kannan, P. K., Late, D. J., Morgan, H., & Rout, C. S. (2015) · Nanoscale · doi:10.1039/c5nr03633j · Cited by 454
Nanostructured copper oxide semiconductors
Zoolfakar, A. S., Rani, R. A., Morfa, A. J., O'Mullane, A. P., & Kalantar‐Zadeh, K. (2014) · Refubium (Universitätsbibliothek der Freien Universität Berlin) · doi:10.17169/refubium-19959 · Cited by 448
NO sensors based on semiconducting metal oxide nanostructures: Progress and perspectives
Afzal, A., Cioffi, N., Sabbatini, L., & Torsi, L. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.05.026 · Cited by 428
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Two-dimensional layered nanomaterials for gas-sensing applications
Yang, W., Gan, L., Li, H., & Zhai, T. (2016) · Inorganic Chemistry Frontiers · doi:10.1039/c5qi00251f · Cited by 376
Ma, J., Ren, Y., Zhou, X., Liu, L., Zhu, Y., Cheng, X., Xu, P., Li, X., Deng, Y., & Zhao, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705268 · Cited by 351
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346
Self-citationGraphene-based hybrids for chemiresistive gas sensors
Meng, F.-L., Guo, Z., & Huang, X.-J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.008 · Cited by 337
Photoluminescent Metal–Organic Frameworks for Gas Sensing
Lin, R., Liu, S., Ye, J., Li, X., & Zhang, J. (2016) · Advanced Science · doi:10.1002/advs.201500434 · Cited by 324
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citationBlow-driven triboelectric nanogenerator as an active alcohol breath analyzer
Wen, Z., Chen, J., Yeh, M.-H., Guo, H., Li, Z., Fan, X., Zhang, T., Zhu, L., & Wang, Z. L. (2015) · Nano Energy · doi:10.1016/j.nanoen.2015.06.006 · Cited by 299
Metal oxide semiconductors for gas sensing
Goel, N., Kunal, K., Kushwaha, A., & Kumar, M. (2023) · Engineering Reports · doi:10.1002/eng2.12604 · Cited by 294
Fabrication of nanostructured ZnO thin films based NO 2 gas sensor via SILAR technique
Patil, V. L., Vanalakar, S. A., Patil, P. S., & Kim, J. H. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.08.130 · Cited by 260
Metadata
- Authors
- Tricoli, A., Righettoni, M., & Teleki, A.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2010-08-18
- Volume
- 49
- Issue
- 42
- Pages
- 7632-7659
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2105024153
- Cited by
- 543
- References
- 84
- FWCI
- 22.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.