Electrochemically Driven, Electrode‐Addressable Formation of Functionalized Polydopamine Films for Neural Interfaces
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The electrode-specific formation of polydopamine films is achieved by applying positive voltage to the target electrodes at pH 6.0. The functionalization of the films is simultaneously carried out by co-depositing dopamine with molecules of interest onto the electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Facile Conjugation of Biomolecules onto Surfaces via Mussel Adhesive Protein Inspired Coatings
Lee, H., Rho, J., & Messersmith, P. B. (2009) · Advanced Materials · doi:10.1002/adma.200801222 · Cited by 1,495
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Kim, D. ‐., Richardson‐Burns, S. M., Hendricks, J. L., Sequera, C., & Martin, D. C. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200500594 · Cited by 299
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Cell attachment functionality of bioactive conducting polymers for neural interfaces
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.03.043 · Cited by 258
Ku, S. H., Lee, J. S., & Park, C. B. (2010) · Langmuir · doi:10.1021/la102825p · Cited by 247
A biofunctionalization scheme for neural interfaces using polydopamine polymer
Kang, K., Choi, I. S., & Nam, Y. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.028 · Cited by 158
Self-citationConducting polymers with immobilised fibrillar collagen for enhanced neural interfacing
Liu, X., Yue, Z., Higgins, M. J., & Wallace, G. G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.047 · Cited by 124
Cited by
Liu, Y., Ai, K., & Lu, L. (2014) · Chemical Reviews · doi:10.1021/cr400407a · Cited by 4,794
Zhang, C., Ou, Y., Lei, W., Wan, L., Ji, J., & Xu, Z. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510724 · Cited by 604
Mussel‐Inspired Hydrogels for Self‐Adhesive Bioelectronics
Xie, C., Wang, X., He, H., Ding, Y., & Lu, X. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909954 · Cited by 482
Lee, H. A., Park, E., & Lee, H. (2020) · Advanced Materials · doi:10.1002/adma.201907505 · Cited by 401
Dopamine: Just the Right Medicine for Membranes
Yang, H., Waldman, R. Z., Wu, M., Hou, J., Chen, L., Darling, S. B., & Xu, Z. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705327 · Cited by 347
Metadata
- Authors
- Kang, K., Lee, S., Kim, R., Choi, I. S., & Nam, Y.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2012-11-14
- Volume
- 51
- Issue
- 52
- Pages
- 13101-13104
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2153161556
- Cited by
- 72
- References
- 9
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.