The DOI matches its Crossref record.
Electrosprayed polymer particles: Effect of the solvent properties
Abstract
Electrospraying technology has been studied in many fields to produce particles of various substances from nanoscale to microscale sizes. Unlike pure liquids, droplets formed by electrospraying that are comprised of polymer solutions undergo additional solidification processes involving solvent evaporation, which primarily determine the particle size and morphology. Herein, the effects of the solvent properties on the morphology and dimensions of solidified particles were systematically studied. In general, the size of the solidified spherical particles with smooth surfaces reflected that of the initially formed liquid droplets, which could partially be estimated by theoretical equations developed for pure liquids. Particle sizes increased with an increase in polymer content and a decrease in the boiling point of the volatile solvent. Inhomogeneous drying processes related to phase separation or skin formation resulted in hollow, cuplike, and porous particle structures, with particle sizes and morphologies that were outside of the scope of the theoretical treatments. The selection of a proper solvent or solvent mixture seemed to be a convenient way to control the particle morphologies, such as hollow, cuplike, or porous structures. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There are several methods to prepare microspheres, among which electrospray is a promising method with an extremely strict control on size distribution and high encapsulation efficiency for hydrophobic and hydrophilic drugs”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Park & Lee, 2009
In the citing paper
“However, burst release still existed in the application of SAIB”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Park & Lee, 2009
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 49
- 10.1016/j.jcis.2005.06.001 · DOI
- 10.1063/1.123394 · doi:10.1063/1.123394
- 10.1016/S0168-3659(96)01484-8 · DOI · Paper page
- 10.1007/b100116 · doi:10.1007/b100116
- 10.1021/cm980213b · doi:10.1021/cm980213b
- 10.1143/JJAP.31.L1132 · DOI · Paper page
- 10.1016/S0168-3659(01)00440-0 · DOI · Paper page
- 10.1016/j.supflu.2004.10.006 · DOI · Paper page
- 10.1016/S1672-2515(07)60120-1 · doi:10.1016/s1672-2515(07)60120-1
- Hiroshi Y., 2005, Chaos, 15, 047505, 10.1063/1.2137621 · doi:10.1063/1.2137621
- 10.1016/j.jcis.2005.06.052 · doi:10.1016/j.jcis.2005.06.052
- 10.1002/marc.200600532 · DOI
- 10.1103/PhysRev.10.1 · DOI · Paper page
- 10.1080/14786448208628425 · DOI · Paper page
- 10.1016/0021-9797(71)90141-X · DOI
- 10.1021/la00086a016 · DOI · Paper page
- 10.1063/1.868037 · DOI · Paper page
- 10.1098/rspa.1964.0151 · DOI · Paper page
- 10.1146/annurev.fluid.29.1.27 · doi:10.1146/annurev.fluid.29.1.27
- 10.1126/science.2675315 · DOI · Paper page
- 10.1016/S0304-3886(97)00065-X · doi:10.1016/s0304-3886(97)00065-x
- 10.1007/s10853-006-0842-9 · doi:10.1007/s10853-006-0842-9
- 10.1016/j.powtec.2007.01.035 · DOI · Paper page
- Ogata S., 1978, Int Chem Eng, 18, 488
- 10.1299/jsme1958.29.3737 · doi:10.1299/jsme1958.29.3737
- 10.1017/S0022112094003472 · DOI · Paper page
- 10.1016/S0021-8502(98)00780-0 · DOI · Paper page
- 10.1016/j.polymer.2005.04.021 · DOI · Paper page
- 10.1063/1.2259812 · doi:10.1063/1.2259812
- 10.1016/j.jconrel.2004.10.011 · doi:10.1016/j.jconrel.2004.10.011
- 10.1002/bit.21334 · DOI
- 10.1080/02652040500435048 · DOI
- 10.1016/j.polymer.2004.11.116 · doi:10.1016/j.polymer.2004.11.116
- 10.1126/science.1067595 · DOI · Paper page
- 10.1016/j.jcis.2006.06.037 · DOI · Paper page
- 10.1016/j.biomaterials.2005.03.033 · DOI
- 10.1016/j.jcis.2007.09.082 · DOI · Paper page
- 10.1063/1.2183351 · doi:10.1063/1.2183351
- 10.1146/annurev.fluid.39.050905.110159 · DOI · Paper page
- 10.1103/PhysRevLett.97.136103 · doi:10.1103/physrevlett.97.136103
- 10.1209/epl/i2003-00457-7 · doi:10.1209/epl/i2003-00457-7
- 10.1002/polb.20615 · doi:10.1002/polb.20615
- 10.1021/ac0101555 · doi:10.1021/ac0101555
- 10.1021/jp025723e · DOI · Paper page
- 10.1002/aic.690450420 · doi:10.1002/aic.690450420
- 10.1016/S1385-8947(01)00289-3 · doi:10.1016/s1385-8947(01)00289-3
- 10.1016/S0021-8502(96)00433-8 · DOI · Paper page
- 10.1016/0021-8502(94)90205-4 · DOI · Paper page
- Brandrup J., 1989, Polymer Handbook
Cited by
Electrospraying of polymers with therapeutic molecules: State of the art
Bock, N., Dargaville, T. R., & Woodruff, M. A. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.03.002 · Cited by 440
Bock, N., Woodruff, M. A., Hutmacher, D. W., & Dargaville, T. R. (2011) · Polymers · doi:10.3390/polym3010131 · Cited by 326
Controlling the morphology of electrospray-generated PLGA microparticles for drug delivery
Almería, B., Deng, W., Fahmy, T. M., & Gomez, A. (2010) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.10.002 · Cited by 277
Zhang, T., Qiu, Y., Song, J., Zhou, P., Liao, H., Cheng, Y., & Wu, X. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1902020 · Cited by 36
Metadata
- Authors
- Park, C. H., & Lee, J.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2009-06-08
- Volume
- 114
- Issue
- 1
- Pages
- 430-437
- ISSN
- 0021-8995
- 1097-4628
- Cited by
- 80
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrosprayed polymer particles: Effect of the solvent properties. https://app.cochat.ai/papers/10.1002/app.30498
- The paper
- Park, C. H., & Lee, J. (2009). Electrosprayed polymer particles: Effect of the solvent properties. Journal of Applied Polymer Science. https://doi.org/10.1002/app.30498
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.