Comparative Study of Fibrillar Collagen Arrangement in the Corneas of Primates and Other Mammals
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This study is a comparative study of the relationship between corneal structure, morphology, and function in a range of mammalian species. X‐ray scattering patterns were gathered at regular spatial intervals over the excised cornea (and in most cases also the scleral rim) of humans, marmosets, horses, cows, pigs, rabbits, and mice. All patterns were analyzed to produce quantitative information regarding the predominant orientation of fibrillar collagen throughout the tissue. The predominant direction of corneal collagen varies between mammals. This variation is not related to the size, shape, or thickness of the cornea or the frequency with which the animal blinks. A relationship does, however, appear to exist between corneal collagen arrangement and visual acuity. An excess of collagen directed toward one or both sets of opposing rectus muscles is a feature of animals that have an intermediate to high level of visual acuity. There is a significant variation in the arrangement of corneal collagen between different mammalian species. This finding may be related to differences in the frequency of action and the forces generated by the various extraocular muscles during eye movement and image fixation. Anat Rec, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233
Self-citationUltrastructure of the corneal stroma: a comparative study
Meek, K. M., & Leonard, D. W. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81364-x · Cited by 166
Self-citationMeek, K. M., Blamires, T., Elliott, G. F., Gyi, T. J., & Nave, C. (1987) · Current Eye Research · doi:10.3109/02713688709034853 · Cited by 161
Self-citationMapping collagen organization in the human cornea: left and right eyes are structurally distinct
Boote, C., Hayes, S., Abahussin, M., & Meek, K. M. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0893 · Cited by 137
Self-citationScott, J. E., & Bosworth, T. R. (1990) · Biochemical Journal · doi:10.1042/bj2700491 · Cited by 75
Cited by
Corneal biomechanics – a review
Kling, S., & Hafezi, F. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12345 · Cited by 194
“Most species present a lower corneal stiffness and a higher viscoelastic creep behaviour than humans, which might be attributed to differences in the fibrillar collagen arrangement.(11) For ex vivo experiments, freshly enucleated porcine corneas are often used(49,58,64,70,87,88,111) because of their similar anatomy co…”
InfluentialFull-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
“This observation was consistent with the results of X-ray diffraction studies, which revealed a strong preferential alignment of collagen fibrils [8], leading to a stiff circumferential and soft radial orientation in the limbus and peripheral regions.”
BackgroundResultInfluentialCorneal collagen—its role in maintaining corneal shape and transparency
Meek, K. M. (2009) · Biophysical Reviews · doi:10.1007/s12551-009-0011-x · Cited by 183
“Other animals show either a uniaxial preferred orientation or a more circular orientation (Boote et al. 2004; Hayes et al. 2007).”
Self-citationQuantification of lamellar orientation in corneal collagen using second harmonic generation images
Mega, Y., Robitaille, M., Zareian, R., McLean, J., Ruberti, J., & DiMarzio, C. (2012) · Optics Letters · doi:10.1364/ol.37.003312 · Cited by 52
Pijanka, J. K., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813022358 · Cited by 38
“Since these properties appear to affect the architecture of corneal collagen, resulting in differences between mammalian species (Hayes et al., 2007), we speculate that they may also partly dictate the organization of scleral collagen.”
BackgroundSelf-citation
Metadata
- Authors
- Hayes, S., Boote, C., Lewis, J., Sheppard, J., Abahussin, M., Quantock, A. J., Purslow, C., Votruba, M., & Meek, K. M.
- Venue
- The Anatomical Record
- Publisher
- Wiley
- Published
- 2007-10-23
- Volume
- 290
- Issue
- 12
- Pages
- 1542-1550
- ISSN
- 1932-8486 (ISSN-L)
- 1932-8494
- OpenAlex
- W1980254567
- Cited by
- 108
- References
- 5
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.