Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 354

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Short‐Term Pulmonary Function Trends Are Predictive of Mortality in Interstitial Lung Disease Associated With Systemic Sclerosis

Goh, Nicole S., Hoyles, Rachel K., Denton, Christopher P., Hansell, David M., Renzoni, Elisabetta A., Maher, Toby M., Nicholson, Andrew G., Wells, Athol U.·2017·Arthritis & Rheumatology

Abstract

Objective: To determine the prognostic value of pulmonary function test (PFT) trends at 1 and 2 years in interstitial lung disease (ILD) associated with systemic sclerosis (SSc). Methods: The prognostic significance of PFT trends at 1 year (n = 162) and 2 years (n = 140) was examined against 15‐year survival in patients with SSc‐associated ILD. PFT trends, expressed as continuous change and as categorical change in separate analyses, were examined against mortality in univariate and multivariate models. SSc‐associated ILD was defined at presentation as either limited lung fibrosis or extensive lung fibrosis, using the United Kingdom Raynaud's and Scleroderma Association severity staging system. Results: One‐year PFT trends were predictive of mortality only in patients with extensive lung fibrosis: categorical change in the forced vital capacity (FVC), alone or in combination with categorical change in the diffusing capacity for carbon monoxide (DL co), had greater prognostic significance than continuous change in the FVC or trends in other PFT variables. Taking into account both prognostic value and sensitivity to change, the optimal definition of progression for trial purposes was an FVC and DL co composite end point, consisting of either an FVC decline from baseline of ≥10% or an FVC decline of 5–9% in association with a DL co decline of ≥15%. At 2 years, gas transfer trends had the greatest prognostic significance, in the whole cohort and in those with limited lung fibrosis. However, in patients with extensive lung fibrosis, the above‐defined FVC and DL co composite end point was the strongest prognostic determinant. Larger changes in the FVC:DL co ratio than in the carbon monoxide transfer coefficient were required to achieve prognostic significance. Conclusion: Based on linkages to long‐term outcomes, these findings provide support for use of routine spirometry and gas transfer monitoring in patients with SSc‐associated ILD, with further evaluation of a composite FVC and DL co end point warranted for trial purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/art.40130

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 354

Metadata

Authors
Goh, N. S., Hoyles, R. K., Denton, C. P., Hansell, D. M., Renzoni, E. A., Maher, T. M., Nicholson, A. G., & Wells, A. U.
Venue
Arthritis & Rheumatology
Publisher
Wiley
Published
2017-07-18
Volume
69
Issue
8
Pages
1670-1678
ISSN
  • 2326-5191 (ISSN-L)
  • 2326-5205
OpenAlex
W2605548119
Cited by
354
References
31
FWCI
21.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.