Human skin permittivity determined by millimeter wave reflection measurements
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Millimeter wave reflection from the human skin was studied in the frequency range of 37–74 GHz in steps of 1 GHz. The forearm and palm data were used to model the skin with thin and thick stratum corneum (SC), respectively. To fit the reflection data, a homogeneous unilayer and three multilayer skin models were tested. Skin permittivity in the mm‐wave frequency range resulted from the permittivity of cutaneous free water which was described by the Debye equation. The permittivity increment found from fitting to the experimental data was used for determination of the complex permittivity and water content of skin layers. Our approach, first tested in pure water and gelatin gels with different water contents, gave good agreement with literature data. The homogeneous skin model fitted the forearm data well. Permittivity of the forearm skin obtained with this model was close to the skin permittivity reported by others. To fit reflection from the palmar skin with a thick SC, a skin model containing at least two layers was required. Multilayer models provided better fitting to both the forearm and palmar skin reflection data. The fitting parameters obtained with different models were consistent with each other. Bioelectromagnetics 28:331–339, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 2×
“Biological tissue permittivity in thegigahertz frequency range is characterized by the g dispersion which results from the polarization of free water molecules [Grant, 1982; Foster and Schwan, 1986; Gabriel et al., 1996].”
Sandby-Møller, J., Poulsen, T., & Wulf, H. C. (2003) · Acta Dermato-Venereologica · doi:10.1080/00015550310015419 · Cited by 737
The influence of age and sex on skin thickness, skin collagen and density
SHUSTER, S., BLACK, M. M., & McVITIE, E. (1975) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1975.tb05113.x · Cited by 640
Cited by
Wu, T., Rappaport, T. S., & Collins, C. M. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377587 · Cited by 243
“Alekseev and Ziskin [69] demonstrated that it was more accurate to describe the temperature distributions during mmWave heating with a multilayer model of skin since heating due to local mmWave exposure affected not only skin but also the subcutaneous tissues, including the fat and muscle.”
InfluentialThe human body and millimeter-wave wireless communication systems: Interactions and implications
Wu, T., Rappaport, T. S., & Collins, C. M. (2015) · 2015 IEEE International Conference on Communications (ICC) · doi:10.1109/icc.2015.7248688 · Cited by 187
Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., et al. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3109249 · Cited by 161
“Variations in the dielectric properties of skin at each body part have also been reported owing to the variation in the thickness of the stratum corneum and the underlying tissues [29].”
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“, the distinct dielectric properties of its layers need be considered [151], [152].”
Metadata
- Authors
- Alekseev, S. I., & Ziskin, M. C.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 2007-04-11
- Volume
- 28
- Issue
- 5
- Pages
- 331-339
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W1965187746
- Cited by
- 194
- References
- 3
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.