pH prediction and control in bioprocesses using mid‐infrared spectroscopy
Open accessThe DOI matches its Crossref record.
Abstract
An on‐line pH monitoring method based on mid‐infrared spectroscopy relevant to bioprocesses is presented. This approach is non‐invasive and does not require the addition of indicators or dyes, since it relies on the analysis of species of common buffers used in culture media, such as phosphate buffer. Starting with titrations of phosphoric and acetic acid solutions over almost the entire pH range (2–12), it was shown that the infrared spectra of all samples can be expressed as a linear combination of the molar absorbance of the acids and their deprotonated forms. In other words, pH had no direct influence on the molar infrared spectra themselves, but only on deprotonation equilibria. Accurate prediction (standard error of prediction for pH < 0.15 pH units) was achieved by taking into account the non‐ideal behavior of the solutions, using the Debye–Hückel theory to estimate the activity coefficients. Batch cultures of E. coli were chosen as a case study to show how this approach can be applied to bioprocess monitoring. The discrepancy between the spectroscopic prediction and the conventional electrochemical probe never exceeded 0.12 pH units, and the technique was fast enough to implement a feedback controller to maintain the pH constant during cultivation. Biotechnol. Bioeng. 2008;100: 82–93. © 2007 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 26
- ASTM, 1997, Standard practices for infrared, multivariate, quantitative analysis (E 1655‐97). Annual book of ASTM standards, 844
- Bailey JE, 1986, Biochemical engineering fundamentals
- 10.1139/cjc-78-4-490 · doi:10.1139/cjc-78-4-490
- 10.1023/A:1026784101162 · DOI
- 10.1021/bp990039b · DOI
- 10.1063/1.1416902 · DOI · Paper page
- 10.1002/bit.10212 · DOI
- 10.1017/S0022029903006344 · DOI
- 10.1007/s00217-005-0110-2 · doi:10.1007/s00217-005-0110-2
- 10.1021/bp0255560 · DOI · Paper page
- 10.1002/bit.10618 · DOI · Paper page
- 10.1016/j.lwt.2006.02.010 · doi:10.1016/j.lwt.2006.02.010
- Martens H, 1992, Multivariate calibration
- 10.1366/0003702981944788 · doi:10.1366/0003702981944788
- 10.1016/S0003-2670(01)95397-8 · DOI
- 10.1007/BF00645465 · DOI · Paper page
- 10.1007/s004490100226 · DOI
- 10.1002/bit.10134 · DOI · Paper page
- 10.1021/bp980022d · DOI
- 10.1016/j.jbiotec.2006.09.015 · DOI
- 10.1016/j.aca.2007.03.056 · DOI
- 10.1351/pac198456050567 · doi:10.1351/pac198456050567
- 10.1021/ac960917 · doi:10.1021/ac960917
- Steyer JP, 2002, On‐line measurement of COD, TOC, VFA, total and partial alkalinity in anaerobic processes using infra‐red spectrometry, Water Sci Technol, 45, 133, 10.2166/wst.2002.0310 · doi:10.2166/wst.2002.0310
- 10.1016/j.medengphy.2005.07.016 · DOI
- 10.1002/9780470938416 · DOI · Paper page
Cited by
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
“…Glucose NIR Roychoudhury et al. (2007a, b)Lactate CHO Antibody MIR Sellick et al. (2010) E. coli Biomass NIR Arnold et al. (2002) E. coli pH MIR Schenk et al. (2008) E. coli XL-1 blue strains QMX-8b and TXC-1a Biomass NIR Kiviharju et al. (2007) G. xylinus Fructose MIR Kornmann et al. (2003)…”
BackgroundKoch, C., Brandstetter, M., Wechselberger, P., Lorantfy, B., Plata, M. R., Radel, S., Herwig, C., & Lendl, B. (2015) · Analytical Chemistry · doi:10.1021/ac504126v · Cited by 35
Podevin, M., Fotidis, I. A., & Angelidaki, I. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1398132 · Cited by 34
Raman spectroscopy as a method to replace off‐line pH during mammalian cell culture processes
Rafferty, C., O'Mahony, J., Burgoyne, B., Rea, R., Balss, K. M., & Latshaw, D. C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27197 · Cited by 31
Metadata
- Authors
- Schenk, J., Marison, I. W., & von Stockar, U.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2007-11-19
- Volume
- 100
- Issue
- 1
- Pages
- 82-93
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1995183712
- Cited by
- 29
- References
- 0
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.