Cited by 12

Determination of protein concentration in downstream biomanufacturing processes by in‐line index of refraction

Harris, Steven A., Patel, Bhumit A., Gospodarek, Adrian, Desai, Jayesh, de Janon Gutiérrez, Alejandro, Botonjic‐Sehic, Edita, Brower, Mark, Pinto, Nuno D. S.·2021·Biotechnology Progress

Abstract

Protein concentration determination is a necessary in‐process control for the downstream operations within biomanufacturing. As production transitions from batch mode to an integrated continuous bioprocess paradigm, there is a growing need to move protein concentration quantitation from off‐line to in‐line analysis. One solution to fulfill this process analytical technology need is an in‐line index of refraction (IoR) sensor to measure protein concentration in real time. Here the performance of an IoR sensor is evaluated through a series of experiments to assess linear response, buffer matrix effects, dynamic range, sensor‐to‐sensor variability, and the limits of detection and quantitation. The performance of the sensor was also tested in two bioprocessing scenarios, ultrafiltration and capture chromatography. The implementation of this in‐line IoR sensor for real‐time protein concentration analysis and monitoring has the potential to improve continuous bioprocess manufacturing.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/btpr.3187

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The IoR sensor accurately measured protein concentrations during ultrafiltration and during the capture step.

    “The sensor was able to accurately measure the protein concentrations during ultrafiltration and during the capture step [109].”
  • Harris et al. employed an IoR sensor in an in-line setup to measure protein concentrations in real time during the capture and ultrafiltration steps of downstream processing.

    “Harris et al. employed a sensor based on Index of Refraction (IoR) forming an in‐line setup to measure the protein concentrations in real time during the capture and ultrafiltration steps of downstream processing.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 25

  1. Rathore AS, Bhambure R, Ghare V. Process analytical technology (PAT) for biopharmaceutical products. Anal Bioanal Chem. 2010;398: 137-154. https://doi.org/10.1007/s00216-010-3781-x · DOI
  2. Hinz DC. Process analytical technologies in the pharmaceutical indus- try: the FDA's PAT initiative. Anal Bioanal Chem. 2006;384:1036- 1042. https://doi.org/10.1007/s00216-005-3394-y · DOI
  3. Esmonde-White KA, Cuellar M, Uerpmann C, Lenain B, Lewis IR. Raman spectroscopy as a process analytical technology for pharma- ceutical manufacturing and bioprocessing. Anal Bioanal Chem. 2017; 409:637-649. https://doi.org/10.1007/s00216-016-9824-1 · DOI · Paper page
  4. Patel BA, Pinto NDS, Gospodarek A, et al. On-line ion exchange liquid chromatography as a process analytical technology for monoclonal antibody characterization in continuous bioprocessing. Anal Chem. 2017;89(21):11357-11365. https://doi.org/10.1021/acs.analchem. 7b02228 · DOI
  5. Subramanian G. Continuous Biomanufacturing: Innovative Technologies and Methods: Wiley Verlag Chemie: Weinheim, Baden-Württemberg; 2017. doi:https://doi.org/10.1002/9783527699902 · DOI
  6. Staby A, Rathore AS, Ahuja S. Preparative Chromatography for Separa- tion of Proteins. John Wiley & Sons: Hoboken, NJ; 2017. doi:https:// doi.org/10.1002/9781119031116 · DOI
  7. Rolinger L, Rüdt M, Diehm J, et alia. Multi-attribute PAT for UF/DF of proteins -monitoring concentration, particle sizes, and buffer exchange. Anal Bioanal Chem 2020; 412: 2123-2136. doi:https://doi. org/10.1007/s00216-019-02318-8 · DOI · Paper page
  8. Yilmaz D, Mehdizadeh H, Navarro D, Shehzad A, O'Connor M, McCormick P. Application of Raman spectroscopy in monoclonal anti- body producing continuous systems for downstream process intensi- fication. Biotechnol Prog. 2020;36(3):e2947. https://doi.org/10.1002/ btpr.2947 · DOI · Paper page
  9. Rüdt M, Briskot T, Hubbuch J. Advances in downstream processing of biologics -spectroscopy: an emerging process analytical technology. J Chromatogr A. 2017;1490:2-9. https://doi.org/10.1016/j.chroma. 2016.11.010 · DOI
  10. Wasalathanthri DP, Feroz H, Puri N, et al. Real-time monitoring of quality attributes by in-line Fourier transform infrared spectroscopic sensors at ultrafiltration and diafiltration of bioprocess. Biotechnol Bioeng. 2020;117:3766-3774. https://doi.org/10.1002/bit.27532 · DOI · Paper page
  11. Thakur G, Hebbi V, Rathore AS. An NIR-based PAT approach for real- time control of loading in protein a chromatography in continuous manufacturing of monoclonal antibodies. Biotechnol Bioeng. 2020; 117:673-686. https://doi.org/10.1002/bit.27236 · DOI · Paper page
  12. Alfred Z, Hecht E. Optics. Fourth ed. London: Pearson Higher Educa- tion; 2003.
  13. Kwan A, Dudley J, Lantz E. Who really discovered Snell's law? Phys World. 2002;15(4):64. https://doi.org/10.1088/2058-7058/15/4/44 · DOI
  14. Ghosh G. Sellmeier coefficients and dispersion of Thermo-optic coef- ficients for some optical glasses. Appl Opt. 1997;36(7):1540-1546. https://doi.org/10.1364/AO.36.001540 · DOI
  15. Webb CE, Jones JDC. Handbook of Laser Technology and Applications, Volume III: Materials Processing and Spectroscopy. First ed. Oxford- shire: Abingdon-on-Thames; 2004:1738-1740.
  16. Palik ED. Refractive index. Handbook of Optical Constants of Solids. Vol 5; Cambridge, Massachusetts: Academic Press; 1997:5-114. https://doi.org/10.1016/B978-012544415-6.50149-7 · DOI
  17. Jenkins FA, White HE. Fundamentals of Optics. (Fourth Edition) ed. New York: McGraw Hill Education; 1981.
  18. Ovsak AS, Morozhenko AV. Corrected spectral dependence of the imaginary part of the refractive index of aerosol in Jupiter's atmosphere in the short-wavelength spectral range. Kinemat Phys Celest Bodies. 2017;33:239-244. https://doi.org/10.3103/S088459131705004X · DOI
  19. Glover F, Goulden J. Relationship between refractive index and con- centration of solutions. Nature. 1963;200:1165-1166. https://doi. org/10.1038/2001165a0 · DOI
  20. Tan CY, Huang YX. Dependence of refractive index on concentration and temperature in electrolyte solution, polar solution, nonpolar solu- tion, and protein solution. J Chem Eng Data. 2015;60(10):2827-2833. https://doi.org/10.1021/acs.jced.5b00018 · DOI
  21. Song Y, Yu D, Mayani M, Mussa N, Li ZJ. Monoclonal antibody higher order structure analysis by high throughput protein conformational array. MAbs. 2018;10(3):397-405. https://doi.org/10.1080/ 19420862.2017.1421880 · DOI
  22. McKechnie WS, Tugcu N, Kandula S. Accurate and rapid protein con- centration measurement of in-process, high concentration protein pools. Biotechnol Prog. 2018;34(5):1234-1241. https://doi.org/10. 1002/btpr.2695 · DOI · Paper page
  23. Zhao H, Brown PH, Schuck P. On the distribution of protein refrac- tive index increments. Biophys J. 2011;100(9):2309-2317. https://doi. org/10.1016/j.bpj.2011.03.004 · DOI
  24. Husband FA, Garrood MJ, Mackie AR, Burnett GR, Wilde PJ. Adsorbed protein secondary and tertiary structures by circular dichro- ism and infrared spectroscopy with refractive index matched emul- sions. J Agric Food Chem. 2001;49(2):859-866. https://doi.org/10. 1021/jf000688z · DOI
  25. International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use. Validation of Analytical Proce- dures: Text and Methodology. Q2(R1)B, 1995. fda.gov/regulatory- information/search-fda-guidance-documents/q2-r1-validation-analyti cal-procedures-text-and-methodology How to cite this article: Harris SA, Patel BA, Gospodarek A, et al. Determination of protein concentration in downstream biomanufacturing processes by in-line index of refraction. Biotechnol Progress. 2021;37(5):e3187. https://doi.org/10. 1002/btpr.3187

Cited by

Sorted by citations

Authors
Harris, S. A., Patel, B. A., Gospodarek, A., Desai, J., de Janon Gutiérrez, A., Botonjic‐Sehic, E., Brower, M., & Pinto, N. D. S.
Affiliations
  • Analytics Group, Digital Innovation Program Central Technology Organization, Pall Corporation Westborough Massachusetts USA
  • Analytical Research and Development Merck & Co., Inc. Kenilworth New Jersey USA
  • Biologics Process Research and Development Merck & Co., Inc. Kenilworth New Jersey USA
  • School of Chemical and Biomolecular Engineering Georgia Institute of Technology Atlanta Georgia USA
Venue
Biotechnology Progress
Publisher
Wiley
Published
2021-07-06
Volume
37
Issue
5
ISSN
  • 8756-7938
  • 1520-6033
Cited by
12
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review