The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Highly Sensitive and Fast Responsive Fluorescence Turn‐On Chemodosimeter for Cu2+ and Its Application in Live Cell Imaging
Abstract
A rhodamine B derivative 4 containing a highly electron‐rich S atom has been synthesized as a fluorescence turn‐on chemodosimeter for Cu 2+. Following Cu 2+‐promoted ring‐opening, redox and hydrolysis reactions, comparable amplifications of absorption and fluorescence signals were observed upon addition of Cu 2+; this suggests that chemodosimeter 4 effectively avoided the fluorescence quenching caused by the paramagnetic nature of Cu 2+. Importantly, 4 can selectively recognize Cu 2+ in aqueous media in the presence of other trace metal ions in organisms (such as Fe 3+, Fe 2+, Cu+, Zn 2+, Cr 3+, Mn 2+, Co 2+, and Ni 2+), abundant cellular cations (such as Na+, K+, Mg 2+, and Ca 2+), and the prevalent toxic metal ions in the environment (such as Pb 2+ and Cd 2+) with high sensitivity (detection limit ≤10 ppb) and a rapid response time (≤1 min). Moreover, by virtue of the chemodosimeter as fluorescent probe for Cu 2+, confocal and two‐photon microscopy experiments revealed a significant increase of intracellular Cu 2+ concentration and the subcellular distribution of Cu 2+, which was internalized into the living HeLa cells upon incubation in growth medium supplemented with 50 μ M CuCl 2 for 20 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
Essentiality of copper in humans
Uauy, R., Olivares, M., & Gonzalez, M. (1998) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/67.5.952s · Cited by 1,052
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Molecular imaging of hydrogen peroxide produced for cell signaling
Miller, E. W., Tulyathan, O., Isacoff, E. Y., & Chang, C. J. (2007) · Nature Chemical Biology · doi:10.1038/nchembio871 · Cited by 450
Xu, K., Liu, X., Tang, B., Yang, G., Yang, Y., & An, L. (2007) · Chemistry – A European Journal · doi:10.1002/chem.200600497 · Cited by 105
Cited by
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Carbon Dots Based Dual-Emission Silica Nanoparticles as a Ratiometric Nanosensor for Cu2+
Liu, X., Zhang, N., Bing, T., & Shangguan, D. (2014) · Analytical Chemistry · doi:10.1021/ac404236y · Cited by 308
Grover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Highly Efficient Fluorescent Material Based on Rare-Earth-Modified Polyhydroxyalkanoates
Yu, L.-P., Zhang, X., Wei, D.-X., Wu, Q., Jiang, X.-R., & Chen, G.-Q. (2019) · Biomacromolecules · doi:10.1021/acs.biomac.8b01722 · Cited by 46
Metadata
- Authors
- Yu, M., Shi, M., Chen, Z., Li, F., Li, X., Gao, Y., Xu, J., Yang, H., Zhou, Z., Yi, T., & Huang, C.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2008-07-30
- Volume
- 14
- Issue
- 23
- Pages
- 6892-6900
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2014418654
- Cited by
- 303
- References
- 5
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Fast Responsive Fluorescence Turn‐On Chemodosimeter for Cu2+ and Its Application in Live Cell Imaging. https://app.cochat.ai/papers/10.1002/chem.200800005
- The paper
- Yu, M., Shi, M., Chen, Z., Li, F., Li, X., Gao, Y., Xu, J., Yang, H., Zhou, Z., Yi, T., & Huang, C. (2008). Highly Sensitive and Fast Responsive Fluorescence Turn‐On Chemodosimeter for Cu2+ and Its Application in Live Cell Imaging. Chemistry – A European Journal. https://doi.org/10.1002/chem.200800005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.