The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Highly Sensitive and Fast Responsive Fluorescence Turn‐On Chemodosimeter for Cu2+ and Its Application in Live Cell Imaging
Abstract
A rhodamine B derivative 4 containing a highly electron‐rich S atom has been synthesized as a fluorescence turn‐on chemodosimeter for Cu 2+. Following Cu 2+‐promoted ring‐opening, redox and hydrolysis reactions, comparable amplifications of absorption and fluorescence signals were observed upon addition of Cu 2+; this suggests that chemodosimeter 4 effectively avoided the fluorescence quenching caused by the paramagnetic nature of Cu 2+. Importantly, 4 can selectively recognize Cu 2+ in aqueous media in the presence of other trace metal ions in organisms (such as Fe 3+, Fe 2+, Cu+, Zn 2+, Cr 3+, Mn 2+, Co 2+, and Ni 2+), abundant cellular cations (such as Na+, K+, Mg 2+, and Ca 2+), and the prevalent toxic metal ions in the environment (such as Pb 2+ and Cd 2+) with high sensitivity (detection limit ≤10 ppb) and a rapid response time (≤1 min). Moreover, by virtue of the chemodosimeter as fluorescent probe for Cu 2+, confocal and two‐photon microscopy experiments revealed a significant increase of intracellular Cu 2+ concentration and the subcellular distribution of Cu 2+, which was internalized into the living HeLa cells upon incubation in growth medium supplemented with 50 μ M CuCl 2 for 20 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
The Wilson disease gene is a putative copper transporting P–type ATPase similar to the Menkes gene
Bull, P. C., Thomas, G. R., Rommens, J. M., Forbes, J. R., & Cox, D. W. (1993) · Nature Genetics · doi:10.1038/ng1293-327 · Cited by 1,948
Lichtman, J. W., & Conchello, J.-A. (2005) · Nature Methods · doi:10.1038/nmeth817 · Cited by 1,742
Copper biochemistry and molecular biology
Linder, M. C., & Hazegh-Azam, M. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/63.5.797 · Cited by 1,430
Vulpe, C., Levinson, B., Whitney, S., Packman, S., & Gitschier, J. (1993) · Nature Genetics · doi:10.1038/ng0193-7 · Cited by 1,418
UNRAVELING THE MECHANISMS INVOLVED IN MOTOR NEURON DEGENERATION IN ALS
Bruijn, L. I., Miller, T. M., & Cleveland, D. W. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144244 · Cited by 1,185
Light Microscopy Techniques for Live Cell Imaging
Stephens, D. J., & Allan, V. J. (2003) · Science · doi:10.1126/science.1082160 · Cited by 1,179
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Self-citationFluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,355
Phosphorescent chemosensors based on heavy-metal complexes
Zhao, Q., Li, F., & Huang, C. (2010) · Chemical Society Reviews · doi:10.1039/b915340c · Cited by 1,249
Self-citationDu, J., Hu, M., Fan, J., & Peng, X. (2012) · Chemical Society Reviews · doi:10.1039/c2cs00004k · Cited by 688
Zhu, A., Qu, Q., Shao, X., Kong, B., & Tian, Y. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201109089 · Cited by 603
In Situ Imaging of Metals in Cells and Tissues
McRae, R., Bagchi, P., Sumalekshmy, S., & Fahrni, C. J. (2009) · Chemical Reviews · doi:10.1021/cr900223a · Cited by 570
Colorimetric metal ion sensors – A comprehensive review of the years 2011–2016
Kaur, B., Kaur, N., & Kumar, S. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.12.002 · Cited by 539
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Kaur, K., Saini, R., Kumar, A., Luxami, V., Kaur, N., Singh, P., & Kumar, S. (2012) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2012.04.013 · Cited by 384
Domaille, D. W., Zeng, L., & Chang, C. J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja907778b · Cited by 352
Hyman, L. M., & Franz, K. J. (2012) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2012.03.009 · Cited by 325
Carbon Dots Based Dual-Emission Silica Nanoparticles as a Ratiometric Nanosensor for Cu2+
Liu, X., Zhang, N., Bing, T., & Shangguan, D. (2014) · Analytical Chemistry · doi:10.1021/ac404236y · Cited by 308
Two-photon luminescent metal complexes for bioimaging and cancer phototherapy
Chen, Y., Guan, R., Zhang, C., Huang, J., Ji, L., & Chao, H. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.09.010 · Cited by 259
Phosphorescent Sensor for Robust Quantification of Copper(II) Ion
You, Y., Han, Y., Lee, Y.-M., Park, S. Y., Nam, W., & Lippard, S. J. (2011) · Journal of the American Chemical Society · doi:10.1021/ja204997c · Cited by 258
Taki, M., Iyoshi, S., Ojida, A., Hamachi, I., & Yamamoto, Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja100714p · Cited by 253
Shanmugaraju, S., Joshi, S. A., & Mukherjee, P. S. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10406c · Cited by 252
Grover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Highly Efficient Fluorescent Material Based on Rare-Earth-Modified Polyhydroxyalkanoates
Yu, L.-P., Zhang, X., Wei, D.-X., Wu, Q., Jiang, X.-R., & Chen, G.-Q. (2019) · Biomacromolecules · doi:10.1021/acs.biomac.8b01722 · Cited by 46
Metadata
- Authors
- Yu, M., Shi, M., Chen, Z., Li, F., Li, X., Gao, Y., Xu, J., Yang, H., Zhou, Z., Yi, T., & Huang, C.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2008-07-30
- Volume
- 14
- Issue
- 23
- Pages
- 6892-6900
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2014418654
- Cited by
- 303
- References
- 51
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.