The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Multivariate statistical monitoring of process operating performance
Abstract
Process computers routinely collect hundreds to thousands of pieces of data from a multitude of plant sensors every few seconds. This has caused a “data overload” and due to the lack of appropriate analyses very little is currently being done to utilize this wealth of information. Operating personnel typically use only a few variables to monitor the plant's performance. However, multivariate statistical methods such as PLS (Partial Least Squares or Projection to Latent Structures) and PCA (Principal Component Analysis) are capable of compressing the information down into low dimensional spaces which retain most of the information. Using this method of statistical data compression a multivariate monitoring procedure analogous to the univariate Shewart Chart has been developed to efficiently monitor the performance of large processes, and to rapidly detect and identify important process changes. This procedure is demonstrated using simulations of two processes, a fluidized bed reactor and an extractive distillation column.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIII. On lines and planes of closest fit to systems of points in space
Pearson, K. (1901) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440109462720 · Cited by 11,934
Wold, S., Esbensen, K., & Geladi, P. (1987) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(87)80084-9 · Cited by 11,606
Ridge regression: Biased estimation for nonorthogonal problems
Hoerl, A. E., & Kennard, R. W. (1970) · Technometrics · doi:10.1080/00401706.1970.10488634 · Cited by 9,648
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992
Addelman, S. (1979) · Technometrics · doi:10.1080/00401706.1979.10489788 · Cited by 6,750
Hahn, G. J., Draper, N., & Smith, H. (1982) · Technometrics · doi:10.2307/1267833 · Cited by 5,773
An Introduction to Multivariate Statistical Analysis.
Skinner, C. J., & Anderson, T. W. (1985) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2981950 · Cited by 3,245
Cross-Validatory Estimation of the Number of Components in Factor and Principal Components Models
Wold, S. (1978) · Technometrics · doi:10.1080/00401706.1978.10489693 · Cited by 2,601
Wold, S., Ruhe, A., Wold, H., & Dunn, III (1984) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0905052 · Cited by 2,529
Höskuldsson, A. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020306 · Cited by 1,881
Cited by
A review of process fault detection and diagnosis
Venkatasubramanian, V., Rengaswamy, R., Yin, K., & Kavuri, S. N. (2003) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00160-6 · Cited by 2,723
A review of process fault detection and diagnosis
Venkatasubramanian, V., Rengaswamy, R., Kavuri, S. N., & Yin, K. (2003) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00162-x · Cited by 1,859
The pls Package: Principal Component and Partial Least Squares Regression in R
Mevik, B.-H., & Wehrens, R. (2007) · Journal of Statistical Software · doi:10.18637/jss.v018.i02 · Cited by 1,782
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Monitoring batch processes using multiway principal component analysis
Nomikos, P., & MacGregor, J. F. (1994) · AIChE Journal · doi:10.1002/aic.690400809 · Cited by 1,483
Self-citationDisturbance detection and isolation by dynamic principal component analysis
Ku, W., Storer, R. H., & Georgakis, C. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00076-3 · Cited by 1,483
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Multivariate SPC Charts for Monitoring Batch Processes
Nomikos, P., & MacGregor, J. F. (1995) · Technometrics · doi:10.1080/00401706.1995.10485888 · Cited by 1,422
Self-citationYin, S., Ding, S. X., Haghani, A., Hao, H., & Zhang, P. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.06.009 · Cited by 1,294
Statistical process control of multivariate processes
MacGregor, J. F., & Kourti, T. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(95)00014-l · Cited by 1,270
Self-citationThe process chemometrics approach to process monitoring and fault detection
Wise, B. M., & Gallagher, N. B. (1996) · Journal of Process Control · doi:10.1016/0959-1524(96)00009-1 · Cited by 852
Multiscale PCA with application to multivariate statistical process monitoring
Bakshi, B. R. (1998) · AIChE Journal · doi:10.1002/aic.690440712 · Cited by 839
Process analysis, monitoring and diagnosis, using multivariate projection methods
Kourti, T. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(94)00079-x · Cited by 780
Process monitoring and diagnosis by multiblock PLS methods
MacGregor, J. F., Jaeckle, C., Kiparissides, C., & Koutoudi, M. (1994) · AIChE Journal · doi:10.1002/aic.690400509 · Cited by 773
Self-citationMulti-way partial least squares in monitoring batch processes
Nomikos, P., & MacGregor, J. F. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00043-7 · Cited by 737
Self-citationChiang, L. H., Russell, E. L., & Braatz, R. D. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(99)00061-1 · Cited by 630
Nonlinear principal component analysis—Based on principal curves and neural networks
Dong, D., & McAvoy, T. J. (1996) · Computers & Chemical Engineering · doi:10.1016/0098-1354(95)00003-k · Cited by 628
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00058-7 · Cited by 525
Reconstruction-Based Fault Identification Using a Combined Index
Yue, H. H., & Qin, S. J. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000141+ · Cited by 509
Kano, M., & Nakagawa, Y. (2008) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2007.07.005 · Cited by 508
Generalized contribution plots in multivariate statistical process monitoring
Westerhuis, J. A., Gurden, S. P., & Smilde, A. K. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00062-9 · Cited by 507
Fault Detection Using the k-Nearest Neighbor Rule for Semiconductor Manufacturing Processes
He, Q. P., & Wang, J. (2007) · IEEE Transactions on Semiconductor Manufacturing · doi:10.1109/tsm.2007.907607 · Cited by 459
Fault detection and identification of nonlinear processes based on kernel PCA
Choi, S. W., Lee, C., Lee, J.-M., Park, J. H., & Lee, I.-B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.05.001 · Cited by 454
Monitoring independent components for fault detection
Kano, M., Tanaka, S., Hasebe, S., Hashimoto, I., & Ohno, H. (2003) · AIChE Journal · doi:10.1002/aic.690490414 · Cited by 410
Modelling and diagnostics of batch processes and analogous kinetic experiments
Wold, S., Kettaneh, N., Fridén, H., & Holmberg, A. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00162-2 · Cited by 380
Fault detection and diagnosis in process data using one-class support vector machines
Mahadevan, S., & Shah, S. L. (2009) · Journal of Process Control · doi:10.1016/j.jprocont.2009.07.011 · Cited by 368
Geometric properties of partial least squares for process monitoring
Li, G., Qin, S. J., & Zhou, D. (2010) · Automatica · doi:10.1016/j.automatica.2009.10.030 · Cited by 368
Missing data methods in PCA and PLS: Score calculations with incomplete observations
Nelson, P. R. C., Taylor, P. A., & MacGregor, J. F. (1996) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(96)00007-x · Cited by 358
Self-citationNon-parametric confidence bounds for process performance monitoring charts
Martin, E. B., & Morris, A. J. (1996) · Journal of Process Control · doi:10.1016/0959-1524(96)00010-8 · Cited by 346
Rännar, S., Lindgren, F., Geladi, P., & Wold, S. (1994) · Journal of Chemometrics · doi:10.1002/cem.1180080204 · Cited by 330
Kourti, T. (2005) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.859 · Cited by 330
Multivariate process monitoring and fault diagnosis by multi-scale PCA
Misra, M., Yue, H. H., Qin, S. J., & Ling, C. (2002) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(02)00093-5 · Cited by 325
A deep belief network based fault diagnosis model for complex chemical processes
Zhang, Z., & Zhao, J. (2017) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2017.02.041 · Cited by 309
Wise, B. M., Gallagher, N. B., Butler, S. W., White, D. D., & Barna, G. G. (1999) · Journal of Chemometrics · doi:10.1002/(sici)1099-128x(199905/08)13:3/4<379::aid-cem556>3.0.co;2-n · Cited by 296
Recent trends on hybrid modeling for Industry 4.0
Sansana, J., Joswiak, M. N., Castillo, I., Wang, Z., Rendall, R., Chiang, L. H., & Reis, M. S. (2021) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2021.107365 · Cited by 296
Ge, Z., & Song, Z. (2007) · Industrial & Engineering Chemistry Research · doi:10.1021/ie061083g · Cited by 294
Reis, M., & Gins, G. (2017) · Processes · doi:10.3390/pr5030035 · Cited by 294
Qin, S. J., & Zheng, Y. (2013) · AIChE Journal · doi:10.1002/aic.13959 · Cited by 263
Statistical monitoring of multivariable dynamic processes with state‐space models
Negiz, A., & Çlinar, A. (1997) · AIChE Journal · doi:10.1002/aic.690430810 · Cited by 259
The state of the art in chemical process control in Japan: Good practice and questionnaire survey
Kano, M., & Ogawa, M. (2010) · Journal of Process Control · doi:10.1016/j.jprocont.2010.06.013 · Cited by 257
Statistical monitoring of multistage, multiphase batch processes
(2002) · IEEE Control Systems · doi:10.1109/mcs.2002.1035216 · Cited by 254
Exponentially weighted moving principal components analysis and projections to latent structures
Wold, S. (1994) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)e0075-f · Cited by 253
Intelligent integrated plant operation system for Six Sigma
Han, C., & Lee, Y.-H. (2002) · Annual Reviews in Control · doi:10.1016/s1367-5788(02)80008-6 · Cited by 63
Rizkin, B. A., Popovich, K., & Hartman, R. L. (2019) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2018.11.016 · Cited by 40
Metadata
- Authors
- Kresta, J. V., Macgregor, J. F., & Marlin, T. E.
- Venue
- The Canadian Journal of Chemical Engineering
- Publisher
- Wiley
- Published
- 1991-02
- Volume
- 69
- Issue
- 1
- Pages
- 35-47
- ISSN
- 0008-4034 (ISSN-L)
- 1939-019X
- OpenAlex
- W1990283595
- Cited by
- 989
- References
- 30
- FWCI
- 33.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.