Central Composite Design Applied to Optimization of Dispersive Liquid–Liquid Microextraction of Cu(II) and Zn(II) in Water Followed by High Performance Liquid Chromatography Determination
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
In this study a new method for the simultaneous determination of Cu(II) and Zn(II) ions in water samples was developed by dispersive liquid–liquid microextraction preconcentration followed by HPLC with UV detection. An experimental design, central composite design, coupled with response‐surface methodology was used for the optimization of the involved experimental parameters. In the proposed approach, 8‐hydroxy quinoline (HOX) was used as a chelating agent and chloroform and methanol were chosen as the best extraction and dispersive solvents, respectively. Some factors influencing the extraction efficiency of copper and zinc ions and their subsequent determinations, including extraction and dispersive solvents kinds and volumes, pH of sample solution, concentration of the chelating agent, salting out effect and reaction time were studied and optimized. Under the optimum conditions, the calibration graphs were linear in the range of 10–4000 µg/L with the detection limits of 3 µg/L and the quantification limits of 10 µg/L for both analytes. The RSD for six replicate measurements of 500 µg/L of Cu 2+ and Zn 2+ were 2.9% and 5.7%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Farajzadeh, M. A., Bahram, M., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.040 · Cited by 234
Self-citationFariña, L., Boido, E., Carrau, F., & Dellacassa, E. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.006 · Cited by 209
Fattahi, N., Samadi, S., Assadi, Y., & Hosseini, M. R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.002 · Cited by 178
Zhao, E., Zhao, W., Han, L., Jiang, S., & Zhou, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.069 · Cited by 170
Farajzadeh, M. A., Vardast, M. R., & Bahram, M. (2009) · Chromatographia · doi:10.1365/s10337-008-0912-z · Cited by 36
Self-citation
Cited by
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476
Beyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241
Mousavi, L., Tamiji, Z., & Khoshayand, M. R. (2018) · Talanta · doi:10.1016/j.talanta.2018.08.002 · Cited by 195
Al-Saidi, H. M., & Emara, A. A. A. (2014) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2011.11.005 · Cited by 125
“…including solidifica-tion of the floating organic drops (Hui Xu et al., 2010; Zanjani et al., 2007), adsorption by nanoparticles (Shi and Lee, 2010), centrifugation and collection of organic phase in special appa-ratuses (Saleh et al., 2009; Farajzadeh et al., 2010a; Farajzadeh et al., 2010b).”
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Metadata
- Authors
- Farajzadeh, M. A., Bahram, M., & Vardast, M. R.
- Venue
- CLEAN – Soil, Air, Water
- Publisher
- Wiley
- Published
- 2010-06
- Volume
- 38
- Issue
- 5-6
- Pages
- 466-477
- ISSN
- 1863-0650 (ISSN-L)
- 1863-0669
- OpenAlex
- W2109417545
- Cited by
- 31
- References
- 10
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Central Composite Design Applied to Optimization of Dispersive Liquid–Liquid Microextraction of Cu(II) and Zn(II) in Water Followed by High Performance Liquid Chromatography Determination. https://app.cochat.ai/papers/10.1002/clen.200900257
- The paper
- Farajzadeh, M. A., Bahram, M., & Vardast, M. R. (2010). Central Composite Design Applied to Optimization of Dispersive Liquid–Liquid Microextraction of Cu(II) and Zn(II) in Water Followed by High Performance Liquid Chromatography Determination. CLEAN – Soil, Air, Water. https://doi.org/10.1002/clen.200900257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.