CoChat

An imaging flow cytometric method for measuring cell division history and molecular symmetry during mitosis

Open access
Filby, Andrew, Perucha, Esperanza, Summers, Huw, Rees, Paul, Chana, Prabhjoat, Heck, Susanne, Lord, Graham M., Davies, Derek · 2011 · Cytometry Part A
Cited by 76

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Asymmetric cell division is an important mechanism for generating cellular diversity, however, techniques for measuring the distribution of fate‐regulating molecules during mitosis have been hampered by a lack of objectivity, quantitation, and statistical robustness. Here we describe a novel imaging flow cytometric approach that is able to report a cells proliferative history and cell cycle position using dye dilution, pH3, and PI staining to then measure the spatial distribution of fluorescent signals during mitosis using CCD‐derived imagery. Using Jurkat cells, resolution of the fluorescently labeled populations was comparable to traditional PMT based cytometers thus eliminating the need to sort cells with specific division histories for microscopy. Subdividing mitotic stages by morphology allowed us to determine the time spent in each cell cycle phase using mathematical modeling approaches. Furthermore high sample throughput allowed us to collect statistically relevant numbers of cells without the need to use blocking agents that artificially enrich for mitotic events. The fluorescent imagery was used to measure PKCζ protein and EEA‐1+ endosome distribution during different mitotic phases in Jurkat cells. While telophase cells represented the favorable population for measuring asymmetry, asynchronously dividing cells spent approximately 43 seconds in this stage, explaining why they were present at such low frequencies. This necessitated the acquisition of large cell numbers. Interestingly we found that PKCζ was inherited asymmetrically in 2.5% of all telophasic events whereas endosome inheritance was significantly more symmetrical. Furthermore, molecular polarity at early mitotic phases was a poor indicator of asymmetry during telophase highlighting that, though rare, telophasic events represented the best candidates for asymmetry studies. In summary, this technique combines the spatial information afforded by fluorescence microscopy with the statistical wealth and objectivity of traditional flow cytometry, overcoming the key limitations of existing approaches for studying asymmetry during mitosis. © 2011 International Society for Advancement of Cytometry

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.21091

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Filby, A., Perucha, E., Summers, H., Rees, P., Chana, P., Heck, S., Lord, G. M., & Davies, D.
Venue
Cytometry Part A
Publisher
Wiley
Published
2011-06-02
Volume
79A
Issue
7
Pages
496-506
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W1585072075
Cited by
76
References
6
FWCI
1.91
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.