Point‐of‐Care Smartphone‐based Electrochemical Biosensing
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Point‐of‐care (PoC) biosensors offer promising solutions to today's adverse and costly healthcare issues by moving diagnostic tools closer to the patient. The ubiquity of smartphones has brought about an emergence of PoC devices, which leverage the smartphone's capabilities, enabling the creation of low‐cost and portable biosensors. Electrochemical biosensors are well suited for PoC testing since the transducers can be miniaturized and inexpensively fabricated. This review paper discusses recent developments in smartphone‐based electrochemical biosensors for PoC diagnostics. These peripherals utilize the various connectivity options (for example proprietary ports, audio headphone‐jack, or wireless radio) to offload functionality to the smartphone. The smartphone‐based implementations of various electrochemical techniques, such as amperometry, potentiometry, and impedance spectroscopy are explored. Major challenges include reducing power, area, and cost of measurement circuitry, while maintaining adequate performance for PoC diagnostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
m-Health adoption by healthcare professionals: a systematic review
Gagnon, M.-P., Ngangue, P., Payne-Gagnon, J., & Desmartis, M. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv052 · Cited by 622
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Paper-based microfluidic system for tear electrolyte analysis
Yetisen, A. K., Jiang, N., Tamayol, A., Ruiz-Esparza, G. U., Zhang, Y. S., Medina-Pando, S., Gupta, A., Wolffsohn, J. S., Butt, H., Khademhosseini, A., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01450j · Cited by 151
Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135
Cited by
Nanozymes in Point-of-Care Diagnosis: An Emerging Futuristic Approach for Biosensing
Das, B., Franco, J. L., Logan, N., Balasubramanian, P., Kim, M. I., & Cao, C. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00717-0 · Cited by 263
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237
Smartphone-assisted personalized diagnostic devices and wearable sensors
Purohit, B., Kumar, A., Mahato, K., & Chandra, P. (2020) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.08.015 · Cited by 159
Metadata
- Authors
- Sun, A. C., & Hall, D. A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2018-11-26
- Volume
- 31
- Issue
- 1
- Pages
- 2-16
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2903287413
- Cited by
- 131
- References
- 8
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.