The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Recent developments in PDMS surface modification for microfluidic devices
Abstract
PDMS is enjoying continued and ever increasing popularity as the material of choice for microfluidic devices due to its low cost, ease of fabrication, oxygen permeability and optical transparency. However, PDMS's hydrophobicity and fast hydrophobic recovery after surface hydrophilization, attributed to its low glass transition temperature of less than −120°C, negatively impacts on the performance of PDMS‐based microfluidic device components. This issue has spawned a flurry of research to devise longer lasting surface modifications of PDMS, with particular emphasis on microfluidic applications. This review will present recent research on surface modifications of PDMS using techniques ranging from metal layer coatings and layer‐by‐layer depositions to dynamic surfactant treatments and the adsorption of amphipathic proteins. We will also discuss significant advances that have been made with a broad palette of gas‐phase processing methods including plasma processing, sol–gel coatings and chemical vapor deposition. Finally, we will present examples of applications and future prospects of modified PDMS surfaces in microfluidics, in areas such as molecular separations, cell culture in microchannels and biomolecular detection via immunoassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Chemical Analysis
(1944) · Nature · doi:10.1038/154102c0 · Cited by 2,687
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
(1998) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826079808001954 · Cited by 1,072
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Surface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Hillborg, H., Ankner, J. F., Gedde, U. W., Smith, G. D., Yasuda, H. K., & Wikström, K. (2000) · Polymer · doi:10.1016/s0032-3861(00)00039-2 · Cited by 511
Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges
Hillborg, H., & Gedde, U. W. (1998) · Polymer · doi:10.1016/s0032-3861(97)00484-9 · Cited by 430
Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting
Hu, S., Ren, X., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N. (2002) · Analytical Chemistry · doi:10.1021/ac025700w · Cited by 418
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
Glass coating for PDMS microfluidic channels by sol–gel methods
Abate, A. R., Lee, D., Do, T., Holtze, C., & Weitz, D. A. (2008) · Lab on a Chip · doi:10.1039/b800001h · Cited by 318
Solution-Phase Surface Modification in Intact Poly(dimethylsiloxane) Microfluidic Channels
Sui, G., Wang, J., Lee, C.-C., Lu, W., Lee, S. P., Leyton, J. V., Wu, A. M., & Tseng, H.-R. (2006) · Analytical Chemistry · doi:10.1021/ac060605z · Cited by 238
Simpson, P. C., Roach, D., Woolley, A. T., Thorsen, T., Johnston, R., Sensabaugh, G. F., & Mathies, R. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.5.2256 · Cited by 234
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Roman, G. T., Hlaus, T., Bass, K. J., Seelhammer, T. G., & Culbertson, C. T. (2005) · Analytical Chemistry · doi:10.1021/ac048811z · Cited by 223
Micro total analysis system (�-TAS) in biotechnology
Lee, S. J., & Lee, S. Y. (2004) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-003-1515-0 · Cited by 222
Zhang, Q., Xu, J.-J., Liu, Y., & Chen, H.-Y. (2008) · Lab Chip · doi:10.1039/b716295m · Cited by 209
Peterson, S. L., McDonald, A., Gourley, P. L., & Sasaki, D. Y. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30166 · Cited by 195
Xiao, D., Zhang, H., & Wirth, M. J. (2002) · Langmuir · doi:10.1021/la0205553 · Cited by 158
Wang, Y., Vaidya, B., Farquar, H. D., Stryjewski, W. J., Hammer, R. P., McCarley, R. L., Soper, S. A., Cheng, Y., & Barany, F. (2003) · Analytical Chemistry · doi:10.1021/ac020683w · Cited by 156
Xiao, D., Le, T. V., & Wirth, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac035254s · Cited by 154
Wu, D., Luo, Y., Zhou, X., Dai, Z., & Lin, B. (2004) · Electrophoresis · doi:10.1002/elps.200406157 · Cited by 144
Makamba, H., Hsieh, Y.-Y., Sung, W., & Chen, S. (2005) · Analytical Chemistry · doi:10.1021/ac0502706 · Cited by 137
Huang, B., Wu, H., Kim, S., & Zare, R. N. (2005) · Lab on a Chip · doi:10.1039/b509251e · Cited by 135
Covalent Micropatterning of Poly(dimethylsiloxane) by Photografting through a Mask
Wang, Y., Lai, H., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N. L. (2005) · Analytical Chemistry · doi:10.1021/ac0509915 · Cited by 133
Hashimoto, M., Barany, F., & Soper, S. A. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.014 · Cited by 132
Roman, G. T., & Culbertson, C. T. (2006) · Langmuir · doi:10.1021/la053085w · Cited by 131
Surface Modification of Confined Microgeometries via Vapor-Deposited Polymer Coatings
Chen, H.-Y., Elkasabi, Y. M., & Lahann, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja057082h · Cited by 129
Wu, D., Zhao, B., Dai, Z., Qin, J., & Lin, B. (2006) · Lab on a Chip · doi:10.1039/b600765a · Cited by 128
Sugiura, S., Edahiro, J., Sumaru, K., et al. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.12.013 · Cited by 99
Solventless Adhesive Bonding Using Reactive Polymer Coatings
Chen, H.-Y., McClelland, A., Chen, Z., & Lahann, J. (2008) · Analytical Chemistry · doi:10.1021/ac800341m · Cited by 97
Simple poly(dimethylsiloxane) surface modification to control cell adhesion
Wu, M. (2008) · Surface and Interface Analysis · doi:10.1002/sia.2964 · Cited by 94
A Self‐Assembly Approach to Chemical Micropatterning of Poly(dimethylsiloxane)
van Poll, M. L., Zhou, F., Ramstedt, M., Hu, L., & Huck, W. T. S. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702286 · Cited by 89
Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies
Heyries, K. A., Loughran, M. G., Hoffmann, D., Homsy, A., Blum, L. J., & Marquette, C. A. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.025 · Cited by 88
Surface characterization of plasma-treated and PEG-grafted PDMS for micro fluidic applications
Sharma, V., Dhayal, M., Govind, G., Shivaprasad, S. M., & Jain, S. (2007) · Vacuum · doi:10.1016/j.vacuum.2007.02.004 · Cited by 88
Wang, B., Kanji, Z. A., Dodwell, E. R., et al. (2003) · Electrophoresis · doi:10.1002/elps.200390186 · Cited by 74
Wang, A., Xu, J., & Chen, H. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.030 · Cited by 70
Moorcroft, M. J. (2005) · Nucleic Acids Research · doi:10.1093/nar/gni075 · Cited by 69
Wu, D., Qin, J., & Lin, B. (2007) · Lab on a Chip · doi:10.1039/b708877a · Cited by 55
Mehta, G., Kiel, M. J., Lee, J. W., Kotov, N. A., Linderman, J. J., & Takayama, S. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200700016 · Cited by 54
Microfluidic enzymatic-reactors for peptide mapping: strategy, characterization, and performance
Wu, H., Zhai, J., Tian, Y., et al. (2004) · Lab on a Chip · doi:10.1039/b408222b · Cited by 54
Surface Modification of Poly(dimethylsiloxane) for Retarding Swelling in Organic Solvents
Lee, J. Y., Kim, M., & Lee, H. H. (2006) · Langmuir · doi:10.1021/la052621h · Cited by 52
Internal Modification of Poly(dimethylsiloxane) Microchannels with a Borosilicate Glass Coating
Orhan, J.-B., Parashar, V. K., Flueckiger, J., & Gijs, M. A. M. (2008) · Langmuir · doi:10.1021/la801317x · Cited by 49
Faure, K., Blas, M., Yassine, O., Delaunay, N., Crétier, G., Albert, M., & Rocca, J. (2007) · Electrophoresis · doi:10.1002/elps.200600566 · Cited by 48
Xu, Y., Li, J., & Wang, E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.062 · Cited by 45
Influence of different amount of Au on the wetting behavior of PDMS membrane
Feng, J., & Zhao, Y. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9110-2 · Cited by 43
Xu, Y., Jiang, H. T., & Wang, E. (2007) · Electrophoresis · doi:10.1002/elps.200700261 · Cited by 42
Chemistry of vegetable physiology and agriculture
(1914) · Journal of the Chemical Society Abstracts · doi:10.1039/ca9140601112 · Cited by 38
Chemical Force Titrations of Amine- and Sulfonic Acid-Modified Poly(dimethylsiloxane)
Wang, B., Oleschuk, R. D., & Horton, J. H. (2005) · Langmuir · doi:10.1021/la048388p · Cited by 36
Synthesis studies of sputtering TiO2 films on poly(dimethylsiloxane) for surface modification
Niu, Z., Gao, F., Jia, X., Zhang, W., Chen, W., & Qian, K. (2005) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2005.07.024 · Cited by 35
PDMS-based microfluidics for proteomic analysis
Dodge, A., Brunet, E., Chen, S., Goulpeau, J., Labas, V. R., Vinh, J., & Tabeling, P. (2006) · The Analyst · doi:10.1039/b606394b · Cited by 34
Qing, Z., Xu, J., & Chen, H. (2006) · Electrophoresis · doi:10.1002/elps.200600024 · Cited by 33
Roman, G. T., Carroll, S., McDaniel, K., & Culbertson, C. T. (2006) · Electrophoresis · doi:10.1002/elps.200500795 · Cited by 26
Miyaki, K., Zeng, H., Nakagama, T., et al. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.030 · Cited by 23
Cited by
Continuous directional water transport on the peristome surface of Nepenthes alata
Chen, H., Zhang, P., Zhang, L., Liu, H., Jiang, Y., Zhang, D., Han, Z., & Jiang, L. (2016) · Nature · doi:10.1038/nature17189 · Cited by 1,261
Skin-inspired hydrogel–elastomer hybrids with robust interfaces and functional microstructures
Yuk, H., Zhang, T., Parada, G. A., Liu, X., & Zhao, X. (2016) · Nature Communications · doi:10.1038/ncomms12028 · Cited by 1,035
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Self-citationPDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Metadata
- Authors
- Zhou, J., Ellis, A. V., & Voelcker, N. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2009-12-28
- Volume
- 31
- Issue
- 1
- Pages
- 2-16
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2152585695
- Cited by
- 857
- References
- 56
- FWCI
- 21.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.