Recent developments in PDMS surface modification for microfluidic devices
Abstract
PDMS is enjoying continued and ever increasing popularity as the material of choice for microfluidic devices due to its low cost, ease of fabrication, oxygen permeability and optical transparency. However, PDMS's hydrophobicity and fast hydrophobic recovery after surface hydrophilization, attributed to its low glass transition temperature of less than −120°C, negatively impacts on the performance of PDMS‐based microfluidic device components. This issue has spawned a flurry of research to devise longer lasting surface modifications of PDMS, with particular emphasis on microfluidic applications. This review will present recent research on surface modifications of PDMS using techniques ranging from metal layer coatings and layer‐by‐layer depositions to dynamic surfactant treatments and the adsorption of amphipathic proteins. We will also discuss significant advances that have been made with a broad palette of gas‐phase processing methods including plasma processing, sol–gel coatings and chemical vapor deposition. Finally, we will present examples of applications and future prospects of modified PDMS surfaces in microfluidics, in areas such as molecular separations, cell culture in microchannels and biomolecular detection via immunoassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Chemical Analysis
(1944) · Nature · doi:10.1038/154102c0 · Cited by 2,687
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
(1998) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826079808001954 · Cited by 1,072
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Surface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Hillborg, H., Ankner, J. F., Gedde, U. W., Smith, G. D., Yasuda, H. K., & Wikström, K. (2000) · Polymer · doi:10.1016/s0032-3861(00)00039-2 · Cited by 511
Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges
Hillborg, H., & Gedde, U. W. (1998) · Polymer · doi:10.1016/s0032-3861(97)00484-9 · Cited by 430
Cited by
Continuous directional water transport on the peristome surface of Nepenthes alata
Chen, H., Zhang, P., Zhang, L., Liu, H., Jiang, Y., Zhang, D., Han, Z., & Jiang, L. (2016) · Nature · doi:10.1038/nature17189 · Cited by 1,261
Skin-inspired hydrogel–elastomer hybrids with robust interfaces and functional microstructures
Yuk, H., Zhang, T., Parada, G. A., Liu, X., & Zhao, X. (2016) · Nature Communications · doi:10.1038/ncomms12028 · Cited by 1,035
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Self-citationPDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Surface Modification of Polymers: Methods and Applications
Nemani, S. K., Annavarapu, R. K., Mohammadian, B., Raiyan, A., Heil, J., Haque, M. A., Abdelaal, A., & Sojoudi, H. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201801247 · Cited by 484
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
Oxygen plasma treatment for reducing hydrophobicity of a sealed polydimethylsiloxane microchannel
Tan, S. H., Nguyen, N.-T., Chua, Y. C., & Kang, T. G. (2010) · Biomicrofluidics · doi:10.1063/1.3466882 · Cited by 440
Anti-fouling Coatings of Poly(dimethylsiloxane) Devices for Biological and Biomedical Applications
Zhang, H., & Chiao, M. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0029-4 · Cited by 415
Stretchable electronics: functional materials, fabrication strategies and applications
Wu, W. (2019) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2018.1549460 · Cited by 347
Surface modification for PDMS‐based microfluidic devices
Zhou, J., Khodakov, D. A., Ellis, A. V., & Voelcker, N. H. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100482 · Cited by 344
Self-citationIndustrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
3D-printed microfluidic devices: fabrication, advantages and limitations—a mini review
Chen, C., Mehl, B. T., Munshi, A. S., Townsend, A. D., Spence, D. M., & Martin, R. S. (2016) · Analytical Methods · doi:10.1039/c6ay01671e · Cited by 303
Recent progress in fabrication and application of polydimethylsiloxane sponges
Zhu, D., Handschuh-Wang, S., & Zhou, X. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta04577h · Cited by 278
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
van Midwoud, P. M., Janse, A., Merema, M. T., Groothuis, G. M. M., & Verpoorte, E. (2012) · Analytical Chemistry · doi:10.1021/ac300771z · Cited by 274
Gökaltun, A., Kang, Y. B., Yarmush, M. L., Usta, O. B., & Asatekin, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43625-5 · Cited by 269
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
A microfluidics platform for combinatorial drug screening on cancer biopsies
Eduati, F., Utharala, R., Madhavan, D., Neumann, U. P., Longerich, T., Cramer, T., Saez-Rodriguez, J., & Merten, C. A. (2018) · Nature Communications · doi:10.1038/s41467-018-04919-w · Cited by 239
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Metadata
- Authors
- Zhou, J., Ellis, A. V., & Voelcker, N. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2009-12-28
- Volume
- 31
- Issue
- 1
- Pages
- 2-16
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2152585695
- Cited by
- 857
- References
- 56
- FWCI
- 21.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.