Coupling imaged capillary isoelectric focusing with mass spectrometry using a nanoliter valve
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Imaged capillary isoelectric focusing (iCIEF) is a powerful separation technique applied frequently for the analysis of biotherapeutics. However, direct mass spectrometric characterization is usually not possible. Here, focused peaks from an iCIEF system are transferred to a four‐port nanoliter valve where peaks of interest are cut and transferred directly (flow injection) or via capillary zone electrophoresis to electrospray mass spectrometry. At first, flow injection coupling was tested with a mixture of peptides showing intraday precision (RSD) of 20.0 and 3.4% in area and 15.2 and 6.3% in intensity for angiotensin I and leucine‐enkephalin, respectively. For the analysis of charge variants in an intact mAb, flow injection and CZE as second dimension were compared, demonstrating the usability of flow injection even for large proteins. However, improved spectra quality was achieved when CZE‐MS was applied. In this way, accurate masses were obtained not only for the main isoform, but also for the main acidic and basic variants. These results demonstrate the power of iCIEF‐CZE‐MS for the analysis of biotherapeutics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04608 · Cited by 123
Gahoual, R., Burr, A., Busnel, J.-M., Kuhn, L., Hammann, P., Beck, A., François, Y.-N., & Leize-Wagner, E. (2013) · mAbs · doi:10.4161/mabs.23995 · Cited by 90
Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0542-0 · Cited by 79
Self-citation
Cited by
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Self-citationDai, J., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04396 · Cited by 46
Multi‐Dimensional Technology—Recent Advances and Applications for Biotherapeutic Characterization
Bouvarel, T., Camperi, J., & Guillarme, D. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300928 · Cited by 20
Heart‐cut nano‐LC–CZE–MS for the characterization of proteins on the intact level
Jooß, K., Scholz, N., Meixner, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800411 · Cited by 19
Self-citation
Metadata
- Authors
- Montealegre, C., & Neusüß, C.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2018-03-12
- Volume
- 39
- Issue
- 9-10
- Pages
- 1151-1154
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2793428027
- Cited by
- 48
- References
- 3
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coupling imaged capillary isoelectric focusing with mass spectrometry using a nanoliter valve. https://app.cochat.ai/papers/10.1002/elps.201800013
- The paper
- Montealegre, C., & Neusüß, C. (2018). Coupling imaged capillary isoelectric focusing with mass spectrometry using a nanoliter valve. ELECTROPHORESIS. https://doi.org/10.1002/elps.201800013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.