The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Subtle in-scanner motion biases automated measurement of brain anatomy from in vivo MRI: Motion Bias in Analyses of Structural MRI
Open accessAbstract
While the potential for small amounts of motion in functional magnetic resonance imaging (fMRI) scans to bias the results of functional neuroimaging studies is well appreciated, the impact of in-scanner motion on morphological analysis of structural MRI is relatively under-studied. Even among "good quality" structural scans, there may be systematic effects of motion on measures of brain morphometry. In the present study, the subjects' tendency to move during fMRI scans, acquired in the same scanning sessions as their structural scans, yielded a reliable, continuous estimate of in-scanner motion. Using this approach within a sample of 127 children, adolescents, and young adults, significant relationships were found between this measure and estimates of cortical gray matter volume and mean curvature, as well as trend-level relationships with cortical thickness. Specifically, cortical volume and thickness decreased with greater motion, and mean curvature increased. These effects of subtle motion were anatomically heterogeneous, were present across different automated imaging pipelines, showed convergent validity with effects of frank motion assessed in a separate sample of 274 scans, and could be demonstrated in both pediatric and adult populations. Thus, using different motion assays in two large non-overlapping sets of structural MRI scans, convergent evidence showed that in-scanner motion-even at levels which do not manifest in visible motion artifact-can lead to systematic and regionally specific biases in anatomical estimation. These findings have special relevance to structural neuroimaging in developmental and clinical datasets, and inform ongoing efforts to optimize neuroanatomical analysis of existing and future structural MRI datasets in non-sedated humans. Hum Brain Mapp 37:2385-2397, 2016. © 2016 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is increasingly recognized that motion in the scanner can significantly influence measures of cortical thickness and surface area27, 218, as well as DTI parameters (Box 2)219 and resting-state networks (Box 3)220,219.”
From Imaging structural and functional brain development in early childhood (2018) · cites this paper as [218]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2000) · doi:10.32614/r.manuals · Cited by 355,893
Desikan, R. S., Ségonne, F., Fischl, B., Quinn, B. T., Dickerson, B. C., Blacker, D., Buckner, R. L., Dale, A. M., Maguire, R. P., Hyman, B. T., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.021 · Cited by 13,324
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Power, J. D., Barnes, K. A., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.018 · Cited by 7,429
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. M. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 7,018
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Automatically Parcellating the Human Cerebral Cortex
Fischl, B. R. (2003) · Cerebral Cortex · doi:10.1093/cercor/bhg087 · Cited by 4,208
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C., Poline, J.-B., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431 · cited 1×
“For the CIVET analysis, images were registered into a standardized stereotaxic space by means of a linear transformation and corrected for intensity non-uniformities [Collins et al., 1994; Sled et al., 1998].”
MethodAdaptive linear step-up procedures that control the false discovery rate
Benjamini, Y., Krieger, A. M., & Yekutieli, D. (2006) · Biometrika · doi:10.1093/biomet/93.3.491 · Cited by 3,228
The influence of head motion on intrinsic functional connectivity MRI
Van Dijk, K. R. A., Sabuncu, M. R., & Buckner, R. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.044 · Cited by 2,344
A hybrid approach to the skull stripping problem in MRI
Ségonne, F., Dale, A. M., Busa, E., Glessner, M., Salat, D. H., Hahn, H., & Fischl, B. R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.032 · Cited by 2,227
Sequence-independent segmentation of magnetic resonance images
Fischl, B. R., Salat, D. H., van der Kouwe, A. J. W., Makris, N., Ségonne, F., Quinn, B. T., & Dale, A. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.016 · Cited by 2,117
Fischl, B. R., Liu, A., & Dale, A. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906426 · Cited by 1,755
Jovicich, J., Czanner, S., Greve, D. N., Haley, E., van der Kouwe, A. J. W., Gollub, R. L., Kennedy, D. N., Schmitt, F., Brown, G. G., MacFall, J. R., et al. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.046 · Cited by 1,269
Satterthwaite, T. D., Wolf, D. H., Loughead, J., Ruparel, K., Elliott, M. A., Hakonarson, H., Gur, R. C., & Gur, R. E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.063 · Cited by 1,125
Geometrically Accurate Topology-Correction of Cortical Surfaces Using Nonseparating Loops
Ségonne, F., Pacheco, J., & Fischl, B. R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.887364 · Cited by 995
Kim, J. S., Singh, V., Lee, J. K., Lerch, J. P., Ad-Dab’bagh, Y., MacDonald, D. J., Lee, J. M., Kim, S. I., & Evans, A. C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.036 · Cited by 816
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 806
Raznahan, A., Shaw, P., Lalonde, F., Stockman, M., Wallace, G. L., Greenstein, D., Clasen, L., Gogtay, N., & Giedd, J. N. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.0054-11.2011 · Cited by 712
Self-citationFast and robust parameter estimation for statistical partial volume models in brain MRI
Tohka, J., Zijdenbos, A. P., & Evans, A. C. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.05.007 · Cited by 670
On standardizing the MR image intensity scale
Ny�l, L. G., & Udupa, J. K. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6 · Cited by 575
Artifacts due to stimulus correlated motion in functional imaging of the brain
Hajnal, J. V., Myers, R., Oatridge, A., Schwieso, J. E., YOUNG, I. R., & Bydder, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310307 · Cited by 486
Head motion during MRI acquisition reduces gray matter volume and thickness estimates
Reuter, M., Tisdall, M. D., Qureshi, A., Buckner, R. L., van der Kouwe, A. J. W., & Fischl, B. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.006 · Cited by 457
Brain Size and Cortical Structure in the Adult Human Brain
Im, K., Lee, J., Lyttelton, O. C., Kim, S. H., Evans, A. C., & Kim, S. I. (2008) · Cerebral Cortex · doi:10.1093/cercor/bhm244 · Cited by 439
Integrated strategy for improving functional connectivity mapping using multiecho fMRI
Kundu, P., Brenowitz, N. D., Voon, V., Worbe, Y., Vértes, P. E., Inati, S. J., Saad, Z. S., Bandettini, P. A., & Bullmore, E. T. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301725110 · Cited by 399
Zaitsev, M., Dold, C., Sakas, G., Hennig, J., & Speck, O. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.039 · Cited by 392
PROMO: Real‐time prospective motion correction in MRI using image‐based tracking
White, N. S., Roddey, J. C., Shankaranarayanan, A., Han, E. T., Rettmann, D. W., Santos, J. M., Kuperman, J., & Dale, A. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22176 · Cited by 377
A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series
Patel, A. X., Kundu, P., Rubinov, M., Jones, P. S., Vértes, P. E., Ersche, K. D., John Suckling, A., & Bullmore, E. T. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.012 · Cited by 354
What is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353
Motion correction and the use of motion covariates in multiple‐subject fMRI analysis
Johnstone, T., Walsh, K. S. O., Greischar, L. L., Alexander, A. L., Fox, A. S., Davidson, R. J., & Oakes, T. R. (2006) · Human Brain Mapping · doi:10.1002/hbm.20219 · Cited by 326
MR image artifacts from periodic motion
Wood, M. L., & Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595782 · Cited by 306
Ducharme, S., Albaugh, M. D., Nguyen, T.-V., Hudziak, J. J., Mateos-Pérez, J. M., Labbe, A., Evans, A. C., & Karama, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.010 · Cited by 304
Gender difference analysis of cortical thickness in healthy young adults with surface-based methods
Im, K., Lee, M.-J., Lee, J., Shin, Y.-W., Kim, I. Y., Kwon, J. M., & Kim, S. I. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.042 · Cited by 294
Atkinson, D., Hill, D., Stoyle, P. N. R., Summers, P. E., & Keevil, S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650886 · Cited by 282
Jo, H. J., Gotts, S. J., Reynolds, R. C., Bandettini, P. A., Martin, A. D., Cox, R. W., & Saad, Z. S. (2013) · Journal of Applied Mathematics · doi:10.1155/2013/935154 · Cited by 277
Real‐time rigid body motion correction and shimming using cloverleaf navigators
van der Kouwe, A. J. W., Benner, T., & Dale, A. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21038 · Cited by 231
Spherical navigator echoes for full 3D rigid body motion measurement in MRI
Welch, E. B., Manduca, A., Grimm, R. C., Ward, H. A., & Jack, C. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10012 · Cited by 213
Measurement of Signal-to-Noise and Contrast-to-Noise in the fBIRN Multicenter Imaging Study
Magnotta, V. A., Friedman, L., & BIRN, F. (2006) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-006-0264-x · Cited by 194
Comparison of fMRI motion correction software tools
Oakes, T. R., Johnstone, T., Walsh, K. S. O., Greischar, L. L., Alexander, A. L., Fox, A. S., & Davidson, R. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.058 · Cited by 186
Automatic quality assessment in structural brain magnetic resonance imaging
Mortamet, B., Bernstein, M. A., Jack, C. R., Gunter, J. L., Ward, C. P., Britson, P. J., Meuli, R. A., Thiran, J., & Krüger, G. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21992 · Cited by 171
An Image-based Approach to Understanding the Physics of MR Artifacts
Morelli, J. N., Runge, V. M., Ai, F., Attenberger, U. I., Vu, L., Schmeets, S. H., Nitz, W. R., & KIRSCH, J. E. (2011) · Radiographics · doi:10.1148/rg.313105115 · Cited by 171
Prospective real‐time correction for arbitrary head motion using active markers
Ooi, M. B., Krueger, S., Thomas, W. J., Swaminathan, S. V., & Brown, T. R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22082 · Cited by 166
Qin, L., van Gelderen, P., Derbyshire, J. A., Jin, F., Lee, J., de Zwart, J. A., Tao, Y., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22076 · Cited by 152
From genes to folds: a review of cortical gyrification theory
Ronan, L., & Fletcher, P. C. (2014) · Brain Structure and Function · doi:10.1007/s00429-014-0961-z · Cited by 145
Self-citationMotion Artifact in Magnetic Resonance Imaging: Implications for Automated Analysis
Blumenthal, J. D., Zijdenbos, A. P., Molloy, E. A., & Giedd, J. N. (2002) · NeuroImage · doi:10.1006/nimg.2002.1076 · Cited by 137
Self-citationAnisotropic diffusion in kidney: Apparent diffusion coefficient measurements for clinical use
Fukuda, Y., Ohashi, I., Hanafusa, K., Nakagawa, T., Ohtani, S., Annaka, Y., Hayashi, T., & Shibuya, H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200002)11:2 · Cited by 128
Dantendorfer, K., Amering, M., Bankier, A. A., Helbich, T. H., Prayer, D., Youssefzadeh, S., Alexandrowicz, R. W., Imhof, H., & Katschnig, H. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00385-2 · Cited by 95
Adaptive technique for three-dimensional MR imaging of moving structures.
Korin, H. W., Felmlee, J. P., Ehman, R. L., & Riederer, S. J. (1990) · Radiology · doi:10.1148/radiology.177.1.2399320 · Cited by 78
Autocorrection in MR Imaging: Adaptive Motion Correction without Navigator Echoes
Manduca, A., McGee, K. P., Welch, E. B., Felmlee, J. P., Grimm, R. C., & Ehman, R. L. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn19904 · Cited by 61
Prospective motion correction improves diagnostic utility of pediatric MRI scans
Kuperman, J. M., Brown, T. T., Golsefidi, M. A., Erhart, M. J., White, N. S., Roddey, J. C., Shankaranarayanan, A., Han, E. T., Rettmann, D. W., & Dale, A. M. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2205-1 · Cited by 57
Kundu, P., Santin, M. D., Bandettini, P. A., Bullmore, E. T., & Petiet, A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.025 · Cited by 50
Norris, D. G., & Driesel, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1099 · Cited by 47
Preboske, G. M., Gunter, J. L., Ward, C. P., & Jack, C. R. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.049 · Cited by 44
Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging
Weih, K., Driesel, W., von Mengershausen, M., & Norris, D. G. (2004) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-004-0036-x · Cited by 23
Simulation of Acquisition Artefacts in MR Scans: Effects on Automatic Measures of Brain Atrophy
Cámara, Ó., Sneller, B., Ridgway, G. R., Garde, E., Fox, N. C., & Hill, D. (2006) · Lecture notes in computer science · doi:10.1007/11866565_34 · Cited by 9
Buckley (1999) · doi:10.1002/(sici)1522-2594(199901)41:1
Cited by
Sorted by citations
Imaging structural and functional brain development in early childhood
Gilmore, J. H., Knickmeyer, R. C., & Gao, W. (2018) · Nature Reviews Neuroscience · doi:10.1038/nrn.2018.1 · Cited by 1,013
MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites
Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184661 · Cited by 920
On testing for spatial correspondence between maps of human brain structure and function
Alexander-Bloch, A. F., Shou, H., Liu, S., Satterthwaite, T. D., Glahn, D. C., Shinohara, R. T., Vandekar, S. N., & Raznahan, A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.070 · Cited by 947
Self-citationTamnes, C. K., Herting, M. M., Goddings, A.-L., Meuwese, R., Blakemore, S.-J., Dahl, R. E., Güroğlu, B., Raznahan, A., Sowell, E. R., Crone, E. A., et al. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.3302-16.2017 · Cited by 685
Self-citationPredicting brain-age from multimodal imaging data captures cognitive impairment
Liem, F., Varoquaux, G. P., Kynast, J., Beyer, F., Masouleh, S. K., Huntenburg, J. M., Lampe, L., Rahim, M., Abraham, A., Craddock, R. C., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.005 · Cited by 522
Metadata
- Authors
- Alexander-Bloch, A., Clasen, L., Stockman, M., Ronan, L., Lalonde, F., Giedd, J., & Raznahan, A.
- Affiliations
- Developmental Neurogenomics Unit; Child Psychiatry Branch; National Institute of Mental Health; Bethesda Maryland
- National Institutes of Health (US)
- University of Cambridge (GB)
- University of California San Diego (US)
- Corresponding author
- Raznahan, Armin
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2016-03-23
- Volume
- 37
- Issue
- 7
- Pages
- 2385-2397
- ISSN
- 1065-9471 (ISSN-L)
- PMC
- PMC5110234
- OpenAlex
- W2310662295
- Cited by
- 178
- References
- 62
- Citations by year
- 2026: 10 · 2025: 17 · 2024: 18 · 2023: 20 · 2022: 10 · 2021: 21 · 2020: 20 · 2019: 16 · 2018: 22 · 2017: 18 · 2016: 6
- FWCI
- 17.94
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Human Brain Mapping (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Apollo
- Funders
- Wellcome Trust (095692/Z/11/Z)
- National Institutes of Health (Z99 MH999999)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Keywords
- structural MRI, brain morphometry, cortical gray matter volume, cortical thickness, mean curvature, automated brain segmentation, motion estimation, pediatric neuroimaging, convergent validity
- MeSH terms
- Adolescent, Adult, Brain, Child, Child, Preschool, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Motion, Organ Size, Pattern Recognition, Automated, Artifacts, Young Adult, Gray Matter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review