Simultaneous functional magnetic resonance imaging and electrophysiological recording
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to develop a method for obtaining simultaneous electrophysiological and functional magnetic resonance imaging data. Using phantom experiments and tests on several of the investigators, a method for obtaining simultaneous electrophysiological and fMRI data was developed and then tested in three volunteers including two task activation experiments. It was then applied in a sleep experiment (n = 12). Current limiting resistance and low‐pass filtering were added to the electrophysiological circuit. Potential high frequency current loops were avoided in the electrical layout near the subject. MRI was performed at 1.5 T using conventional and echo planar imaging sequences. There was no evidence of subject injury. Expected correlations were observed between the electrophysiological and fMRI data in the task activation experiments. The fMRI data were not significantly degraded by the electrophysiological apparatus. Alpha waves were detected from within the magnet in seven of the 15 experimental sessions. There was degradation of the electrophysiological data due to ballistocardiographic artifacts (pulsatile whole body motion time‐locked to cardiac activity) which varied between subjects from being minimal to becoming large enough to make detection of alpha waves difficult. We concluded that simultaneous fMRI and electrophysiological recording is possible with minor modifications of standard electrophysiological equipment. Our initial results suggest this can be done safely and without compromise of the fMRI data. The usefulness of this technique for studies of such things as sleep and epilepsy is promising. Applications requiring higher precision electrophysiological data, such as evoked response measurements, may require modifications based on ballistocardiographic effects. © 1995 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Self-citationOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationHelmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
Functional magnetic resonance imaging of Brocaʼs area during internal speech
Hinke, R. M., Hu, X., Stillman, A. E., Kim, S.-G., Merkle, H., Salmi, R., & Ugurbil, K. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00018 · Cited by 293
Cited by
A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI
Allen, P. J., Josephs, O., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.2000.0599 · Cited by 1,301
Allen, P. J., Polizzi, G., Krakow, K., Fish, D. R., & Lemieux, L. (1998) · NeuroImage · doi:10.1006/nimg.1998.0361 · Cited by 912
The reinterpretation of dreams: An evolutionary hypothesis of the function of dreaming
Revonsuo, A. (2000) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00004015 · Cited by 676
Correlates of alpha rhythm in functional magnetic resonance imaging and near infrared spectroscopy
Moosmann, M., Ritter, P., Krastel, I., Brink, A., Thees, S., Blankenburg, F., Taskin, B., Obrig, H., & Villringer, A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00344-6 · Cited by 594
Functional neuroimaging of normal human sleep by positron emission tomography
Maquet (2000) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2000.00214.x · Cited by 581
Interictal spikes in focal epileptogenesis
de Curtis, M., & Avanzini, G. (2001) · Progress in Neurobiology · doi:10.1016/s0301-0082(00)00026-5 · Cited by 477
Recording of EEG during fMRI experiments: Patient safety
Lemieux, L., Allen, P. J., Franconi, F., Symms, M. R., & Fish, D. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380614 · Cited by 311
EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures
Krakow, K., Woermann, F. G., Symms, M. R., Allen, P. J., Lemieux, L., Barker, G. J., Duncan, J. S., & Fish, D. R. (1999) · Brain · doi:10.1093/brain/122.9.1679 · Cited by 305
Ritter, P., & Villringer, A. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.008 · Cited by 294
Acquiring simultaneous EEG and functional MRI
Goldman, R. I., Stern, J. M., Engel, J., & Cohen, M. S. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00456-9 · Cited by 284
Self-citationQuality of EEG in simultaneous EEG-fMRI for epilepsy
Bénar, C.-G., Aghakhani, Y., Wang, Y., Izenberg, A., Al-Asmi, A., Dubeau, F., & Gotman, J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00383-8 · Cited by 259
The BOLD Response to Interictal Epileptiform Discharges
Bénar, C.-G., Gross, D. W., Wang, Y., Petre, V., Pike, B., Dubeau, F., & Gotman, J. (2002) · NeuroImage · doi:10.1006/nimg.2002.1164 · Cited by 220
Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI
Bonmassar, G. (2002) · NeuroImage · doi:10.1006/nimg.2002.1125 · Cited by 216
“A fundamental limitation of this combined technique is the noise introduced in the EEG due to motion within the magnetic field, either from cardiac pulsation (ballistocardiogram) or from head movements (Huang-Hellinger et al., 1995).”
BackgroundDebener, S., Mullinger, K. J., Niazy, R. K., & Bowtell, R. W. (2008) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.05.015 · Cited by 205
“, 1993), which was interpreted as being due to pulsatile whole body motion, time-locked to cardiac activity (Huang-Hellinger et al., 1995).”
BackgroundDelta Sleep Deficits in Schizophrenia: Evidence From Automated Analyses of Sleep Data
Keshavan, M. S., Reynolds, C. F., Miewald, J. M., Montrose, D. M., Sweeney, J. A., Vasko, R. C., & Kupfer, D. J. (1998) · Archives of General Psychiatry · doi:10.1001/archpsyc.55.5.443 · Cited by 185
Functional Magnetic Resonance Imaging with Echo Planar Imaging
Kwong, K. K. (1996) · Functional MRI · doi:10.1007/978-88-470-2194-5_16 · Cited by 184
Self-citationStatistical feature extraction for artifact removal from concurrent fMRI-EEG recordings
Liu, Z., de Zwart, J. A., van Gelderen, P., Kuo, L.-W., & Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.042 · Cited by 97
Neuner, I., Arrubla, J., Felder, J., & Shah, N. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.048 · Cited by 48
“Three main mechanisms contribute to the generation of the artefact (Allen et al., 1998; Bonmassar et al., 2002; Debener et al., 2008; Huang-Hellinger et al., 1995; Mullinger et al., 2013; Müri et al., 1998; Tenforde et al., 1983; Yan et al., 2010):”
Metadata
- Authors
- Huang‐Hellinger, F. R., Breiter, H. C., McCormack, G., Cohen, M. S., Kwong, K. K., Sutton, J. P., Savoy, R. L., Weisskoff, R. M., Davis, T. L., Baker, J. R., Belliveau, J. W., & Rosen, B. R.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 3
- Issue
- 1
- Pages
- 13-23
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2095081626
- Cited by
- 117
- References
- 7
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.