CoChat

A comparative evaluation of the tissue responses associated with polymeric implants in the rat and mouse

Kidd, Kameha R., Dal Ponte, Donny B., Kellar, Robert S., Williams, Stuart K. · 2002 · Journal of Biomedical Materials Research
Cited by 36

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

End product application is an important consideration when evaluating a material in an in vivo setting (Didisheim, Cardiovasc Pathol 1993;2:1S–2S). Small animal models allow high through‐put evaluation of biocompatability. Previous preclinical evaluations have often used a rat subcutaneous model for the characterization of material‐tissue interaction. Recent advances in genetic manipulation have provided mouse models with selective expression of a wide range of critical proteins. The rat model does not have many of the resources (i.e., knockouts, SCID, nude) that are present in mouse strains. The availability of these mice provides a resource to delineate the mechanisms regulating the healing associated with implants. However, before the mouse models can be used, they must be validated with respect to their ability to accurately assess tissue reponses to materials. In this study the tissue responses after the implantation of expanded polytetrafluoroethylene (ePTFE) were compared between rat and mouse. Discs of ePTFE (30‐μm internodal distance) were implanted in subcutaneous and epididymal fat tissue of rats (Sprague‐Dawley) and mice (129‐SVJ). After 5 weeks the samples were removed and evaluated for vascular density, inflammation, and fibrous encapsulation. No difference in the vessel density was observed within the peri‐implant subcutaneous and adipose tissue or within the porous material. However, a significant difference was found in the number of activated macrophages and giant cells between these two species. Implants in the rat exhibited greater numbers of activated inflammatory cells in the peri‐implant tissue. The data indicate that the mouse and rat provide a comparable model for evaluating angiogenesis and neovascularization associated with synthetic porous implants. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res 59: 682–689, 2002

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.10032

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Kidd, K. R., Dal Ponte, D. B., Kellar, R. S., & Williams, S. K.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
2001-12-12
Volume
59
Issue
4
Pages
682-689
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2009252634
Cited by
36
References
4
FWCI
1.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.