CoChat

Biocompatibility studies on plasm polymerized interface materials encompassing both hydrophobic and hydrophilic surfaces

Johnson, Steven D., Anderson, James M., Marchant, Roger E. · 1992 · Journal of Biomedical Materials Research
Cited by 65

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The biocompatibility of radiofrequency plasma polymerized films (<100 nm thick) deposited on biomedical polymer supports has been characterized by in vitro and in vivo methods. The polymer interface materials covered a wide range of elemental composition and surface properties, and were prepared from N‐vinyl‐2‐ pyrrolidone, γ‐butyrolactone, n‐hexane, and hexamethyldisilazane (PPHMDSZ). The biocompatibility studies showed that the interface materials were noncytotoxic to mouse and human fibroblasts, as shown by morphologic evaluation, and by determination of extracellular LDH; and they did not stimulate interleukin‐1‐like production from human monocytes, as indicated by a thymocyte proliferation assay. The human fibroblast proliferation assay showed that three of the polymers supported cell growth at levels comparable to, or greater than, polymer controls, while the hydrophobic PPHMDSZ inhibited both cell attachment and proliferation. The response to subcutaneous implantation for all test materials was indicative of biocompatibility, with rapid resolution of the acute phase response and normal wound healing. The wide range of composition and surface properties for the plasma polymerized films evaluated in this study suggest that this general class of materials is likely to exhibit excellent biocompatibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820260707

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 65

Metadata

Authors
Johnson, S. D., Anderson, J. M., & Marchant, R. E.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1992-07
Volume
26
Issue
7
Pages
915-935
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2103365474
Cited by
65
References
5
FWCI
3.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biocompatibility studies on plasm polymerized interface materials encompassing both hydrophobic and hydrophilic surfaces. https://app.cochat.ai/papers/10.1002/jbm.820260707
The paper
Johnson, S. D., Anderson, J. M., & Marchant, R. E. (1992). Biocompatibility studies on plasm polymerized interface materials encompassing both hydrophobic and hydrophilic surfaces. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820260707

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.