The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
In vivo behavior of poly(1,3‐trimethylene carbonate) and copolymers of 1,3‐trimethylene carbonate with D,L‐lactide or ϵ‐caprolactone: Degradation and tissue response
Abstract
The degradation and the tissue response evoked by poly(1,3‐trimethylene carbonate) [poly(TMC)] and copolymers of TMC with either 52 mol % D,L‐lactide (DLLA) or 89 mol % ϵ‐caprolactone (CL) were evaluated in vivo by subcutaneous implantation of polymer films in rats for periods up to one year. Poly(TMC) specimens were extensively degraded after 3 weeks and, as confirmed by histology, totally resorbed in less than a year. A fast linear decrease in thickness and mass without a change in molecular weight was observed. Initially an acute sterile inflammatory tissue reaction, caused by the implantation procedure, was observed, followed by a mild macrophage‐mediated foreign body reaction that lasted during the resorption period of the polymer. It is concluded that in vivo, poly(TMC) is degraded via surface erosion involving cellular‐mediated processes. The degradation of the copolymers was slower than that of poly(TMC), taking place via autocatalyzed bulk hydrolysis, preferentially of ester bonds. The TMC‐DLLA copolymer degraded 20 times faster than the TMC‐CL one. In both cases, the tissue reaction upon implantation resembled a sterile inflammatory reaction followed by a foreign body reaction that led to the polymer encapsulation. Significant mass loss was only observed for the TMC‐DLLA copolymer, which underwent 96% mass loss in 1 year. When extensive mass loss started, a mild‐to‐moderate secondary foreign body reaction, related to clearance of the polymer fragments, was triggered. The results presented in this study demonstrate that poly(TMC) and both TMC copolymers are biodegradable and biocompatible materials, making these polymers attractive for the preparation of short‐ and long‐term degradable devices for soft tissue engineering. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1044–1054, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pitt, G. G., Gratzl, M. M., Kimmel, G. L., Surles, J., & Sohindler, A. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90060-0 · Cited by 857
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Bioresorbability and biocompatibility of aliphatic polyesters
Vert, M., Li, S. M., Spenlehauer, G., & Guerin, P. (1992) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00701240 · Cited by 770
Crescenzi, V., Manzini, G., Calzolari, G., & Borri, C. (1972) · European Polymer Journal · doi:10.1016/0014-3057(72)90109-7 · Cited by 750
Aliphatic polyesters. I. The degradation of poly(ϵ‐caprolactone) in vivo
Pitt, C. G., Chasalow, F. I., Hibionada, Y. M., Klimas, D. M., & Schindler, A. (1981) · Journal of Applied Polymer Science · doi:10.1002/app.1981.070261124 · Cited by 712
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Synthesis, properties, and biodegradation of poly(1,3-trimethylene carbonate)
Zhu, K. J., Hendren, R. W., Jensen, K., & Pitt, C. G. (1991) · Macromolecules · doi:10.1021/ma00008a008 · Cited by 498
The intracellular degradation of poly(ε‐caprolactone)
Woodward, S. C., Brewer, P. S., Moatamed, F., Schindler, A., & Pitt, C. G. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190408 · Cited by 380
Resorbable materials of poly(l-lactide)
Leenslag, J. W., Pennings, A. J., Bos, R. R. M., Rozema, F. R., & Boering, G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90121-9 · Cited by 329
Bos, R. R. M., Rozema, F. B., Boering, G., Nijenhius, A. J., Pennings, A. J., Verwey, A. B., Nieuwenhuis, P., & Jansen, H. W. B. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90128-w · Cited by 271
Albertsson, A., & Eklund, M. (1995) · Journal of Applied Polymer Science · doi:10.1002/app.1995.070570109 · Cited by 193
P.Pêgo, A., Poot, A. A., Grijpma, D. W., & Feijen, J. (2001) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856201744434 · Cited by 188
Self-citationBiodegradable elastomeric scaffolds for soft tissue engineering
Pêgo, A. P., Poot, A. A., Grijpma, D. W., & Feijen, J. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00351-6 · Cited by 175
Self-citationBiodegradation of biomedical polymers
Kopec̆ek, J., & Ulbrich, K. (1983) · Progress in Polymer Science · doi:10.1016/0079-6700(83)90005-9 · Cited by 157
In Vitro Degradation of Trimethylene Carbonate Based (Co)polymers
Pêgo, A. P., Poot, A. A., Grijpma, D. W., & Feijén, J. (2002) · Macromolecular Bioscience · doi:10.1002/mabi.200290000 · Cited by 133
Self-citationPhysical properties of high molecular weight 1,3-trimethylene carbonate and D,L-lactide copolymers
Pêgo, A. P., Poot, A. A., Grijpma, D. W., & Feijén, J. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1025084304766 · Cited by 129
Self-citationThe enzymatic surface erosion of aliphatic polyesters
Pitt, C. G., Hendren, R. W., Schindler, A., & Woodward, S. C. (1984) · Journal of Controlled Release · doi:10.1016/0168-3659(84)90016-6 · Cited by 119
In vivo and in vitro degradation of glycine/DL‐lactic acid copolymers
Schakenraad, J. M., Nieuwenhuis, P., Molenaar, I., Helder, J., Dijkstra, P. J., & Feijen, J. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231105 · Cited by 101
Self-citationKawaguchi, T., Nakano, M., Juni, K., Inoue, S., & Yoshida, Y. (1983) · Chemical and Pharmaceutical Bulletin · doi:10.1248/cpb.31.1400 · Cited by 87
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Kamaly, N., Yameen, B., Wu, J., & Farokhzad, O. C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00346 · Cited by 3,070
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Biodegradable polymers applied in tissue engineering research: a review
Martina, M., & Hutmacher, D. W. (2007) · Polymer International · doi:10.1002/pi.2108 · Cited by 449
Recent developments in biodegradable synthetic polymers
Gunatillake, P., Mayadunne, R., & Adhikari, R. (2006) · Biotechnology Annual Review · doi:10.1016/s1387-2656(06)12009-8 · Cited by 444
Metadata
- Authors
- Pêgo, A. P., Van Luyn, M. J. A., Brouwer, L. A., van Wachem, P. B., Poot, A. A., Grijpma, D. W., & Feijen, J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-10-29
- Volume
- 67A
- Issue
- 3
- Pages
- 1044-1054
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2160277604
- Cited by
- 257
- References
- 19
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.