Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating

Cogan, Stuart F., Edell, David J., Guzelian, Andrew A., Ping Liu, Ying, Edell, Robyn · 2003 · Journal of Biomedical Materials Research Part A

Abstract

Amorphous silicon carbide (a‐SiC) films, deposited by plasma‐enhanced chemical vapor deposition (PECVD), have been evaluated as insulating coatings for implantable microelectrodes. The a‐SiC was deposited on platinum or iridium wire for measurement of electrical leakage through the coating in phosphate‐buffered saline (PBS, pH 7.4). Low leakage currents of <10−11 A were observed over a ±5‐V bias. The electronic resistivity of a‐SiC was 3 × 10 13 Ω‐cm. Dissolution rates of a‐SiC in PBS at 37 and 90°C were determined from changes in infrared absorption band intensities and compared with those of silicon nitride formed by low‐pressure chemical vapor deposition (LPCVD). Dissolution rates of LPCVD silicon nitride were 2 nm/h and 0.4 nm/day at 90 and 37°C, respectively, while a‐SiC had a dissolution rate of 0.1 nm/h at 90°C and no measurable dissolution at 37°C. Biocompatibility was assessed by implanting a‐SiC‐coated quartz discs in the subcutaneous space of the New Zealand White rabbit. Histological evaluation showed no chronic inflammatory response and capsule thickness was comparable to silicone or uncoated quartz controls. Amorphous SiC‐coated microelectrodes were implanted in the parietal cortex for periods up to 150 days and the cortical response evaluated by histological evaluation of neuronal viability at the implant site. The a‐SiC was more stable in physiological saline than LPCVD Si 3 N 4 and well tolerated in the cortex. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 856–867, 2003

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.10152

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 169

Metadata

Authors
Cogan, S. F., Edell, D. J., Guzelian, A. A., Ping Liu, Y., & Edell, R.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-10-20
Volume
67A
Issue
3
Pages
856-867
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2112181062
Cited by
169
References
5
FWCI
0.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating. https://app.cochat.ai/papers/10.1002/jbm.a.10152
The paper
Cogan, S. F., Edell, D. J., Guzelian, A. A., Ping Liu, Y., & Edell, R. (2003). Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10152

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.