CoChat

Preparation of porcine carotid arteries for vascular tissue engineering applications

McFetridge, Peter S., Daniel, Joel W., Bodamyali, Tulin, Horrocks, Michael, Chaudhuri, Julian B. · 2004 · Journal of Biomedical Materials Research Part A
Cited by 134

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Biomaterials derived from tissue continue to offer viable alternatives to synthetic materials when autologous materials are unavailable for transplantation due to their unique chemical and mechanical properties. Tissue processing aims to stabilize the material against host degradation and render it immunologically inert by removing cellular material and crosslinking the structural proteins. It is clear that different approaches taken to achieve these goals have very different chemical and mechanical effects on the material. We describe herein the development of a tissue processing methodology to generate acellular scaffolds for tissue engineering small‐diameter vascular grafts. Carotid arteries were isolated from Great White pigs and exposed to various solvent treatments, xylene, butanol, and ethanol to determine optimal parameters for the extraction of host lipids. The tissue was then exposed to a limited proteolysis with trypsin to disrupt cellular protein. This resulted in a controlled digestion that disrupted porcine nuclear DNA and cleared bulk cellular protein, leaving the more resistant structural proteins largely intact and retaining the bulk mechanical properties of the matrix. Histological analysis and scanning electron microscopy illustrated the complete removal of intact cells and nuclear material. The decellularized graft was stabilized by crosslinking with the photooxidative dye methylene green in the presence of 30,000 LUX of broad‐band light energy. High‐performance liquid chromatography analysis showed that the crosslinked tissue yielded 78.6% less hydroxyproline, compared with control tissue, after 20 h incubation with pepsin. Analysis of the crosslinked vessels' burst‐pressure and stress–strain characteristics have shown comparable mechanical properties to those of control vessels. Assessment of in vitro cell adhesion and compatibility was conducted by seeding primary human umbilical vein endothelial cells and adult human vascular smooth muscle cells onto the lumenal and ablumenal surfaces, respectively; these cells were shown to adhere and proliferate under traditional static culture conditions. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 70A: 224–234, 2004

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30060

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
McFetridge, P. S., Daniel, J. W., Bodamyali, T., Horrocks, M., & Chaudhuri, J. B.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2004-06-04
Volume
70A
Issue
2
Pages
224-234
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2225425591
Cited by
134
References
1
FWCI
5.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.