Effects of adsorbed proteins and surface chemistry on foreign body giant cell formation, tumor necrosis factor alpha release and procoagulant activity of monocytes
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The adhesion and activation of monocytes and macrophages are thought to affect the foreign body response to implanted medical devices. However, these cells interact with devices indirectly, because of the prior adsorption of proteins. Therefore, we preadsorbed several “model” biomaterial surfaces with proteins and then measured foreign body giant cell (FBGC) formation, tumor necrosis factor alpha (TNFα) release, and procoagulant activity. The model surfaces were tissue culture polystyrene (TCPS), untreated polystyrene (PS), and Primaria, whereas the proteins used were albumin, fibronectin, fibrinogen, and immunoglobulin. FBGC formation, TNFα release, and procoagulant activity of monocytes were the highest for surfaces preadsorbed with IgG. FBGC formation was lower on surfaces with adsorbed fibrinogen and fibronectin than on uncoated surfaces. TNFα release and procoagulant activity of monocytes were similar on surface adsorbed with fibrinogen, fibronectin, or albumin. Monocyte activation was also affected by the surface chemistry of the substrates, because FBGC formation was the highest on PS and the lowest on TCPS. Monocyte procoagulant activity was the highest on Primaria. Adsorbed proteins and surface chemistry were found to have strong effects on FBGC formation, monocyte TNFα release, and procoagulant activity in vitro, providing support for the idea that these same variables could affect macrophage‐mediated foreign body response to biomaterials in vivo. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 70A: 533–541, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Secretory products of macrophages.
Nathan, C. F. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112815 · Cited by 2,615
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
Interleukin-13 induces human monocyte/macrophage fusion and macrophage mannose receptor expression
DeFife, K. M., Jenney, C. R., McNally, A. K., Colton, E., & Anderson, J. M. (1997) · The Journal of Immunology · doi:10.4049/jimmunol.158.7.3385 · Cited by 228
McNally, A. K., & Anderson, J. M. (2002) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64882-1 · Cited by 225
Human monocyte/macrophage activation and interleukin 1 generation by biomedical polymers
Miller, K. M., & Anderson, J. M. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220805 · Cited by 156
Role for interleukin‐4 in foreign‐body giant cell formation on a poly(etherurethane urea) in vivo
Kao, W. J., McNally, A. K., Hiltner, A., & Anderson, J. M. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291014 · Cited by 154
Cytokine and growth factor production by monocytes/macrophages on protein preadsorbed polymers
Bonfield, T. L., Colton, E., Marchant, R. E., & Anderson, J. M. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260702 · Cited by 119
Bonfield, T. L., Colton, E., & Anderson, J. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230602 · Cited by 76
Cited by
Protein-nanoparticle interactions
Lynch, I., & Dawson, K. A. (2008) · Nano Today · doi:10.1016/s1748-0132(08)70014-8 · Cited by 1,727
Protein−Nanoparticle Interactions: Opportunities and Challenges
Mahmoudi, M., Lynch, I., Ejtehadi, M. R., Monopoli, M. P., Bombelli, F. B., & Laurent, S. (2011) · Chemical Reviews · doi:10.1021/cr100440g · Cited by 1,426
Cellular Uptake, Intracellular Trafficking, and Cytotoxicity of Nanomaterials
Zhao, F., Zhao, Y., Liu, Y., Chang, X., Chen, C., & Zhao, Y. (2011) · Small · doi:10.1002/smll.201100001 · Cited by 1,175
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Lynch, I., Cedervall, T., Lundqvist, M., Cabaleiro-Lago, C., Linse, S., & Dawson, K. A. (2007) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2007.04.021 · Cited by 711
Metadata
- Authors
- Shen, M., Garcia, I., Maier, R. V., & Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2004-07-27
- Volume
- 70A
- Issue
- 4
- Pages
- 533-541
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1986655848
- Cited by
- 98
- References
- 9
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.