Synthetic MMP‐13 degradable ECMs based on poly(N‐isopropylacrylamide‐co‐acrylic acid) semi‐interpenetrating polymer networks. I. Degradation and cell migration
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Thermoresponsive and injectable semi‐interpenetrating polymer networks (sIPNs) containing a biospecific cell‐adhesive signal and proteolytically degradable domains were developed as a synthetic equivalent of the extracellular matrix (ECM). The sIPNs synthesized define a modular hydrogel ECM where different properties of the matrix can be manipulated independently, thus creating a system where parametric analysis of the effect of hydrogel properties on cell proliferation and differentiation is possible. sIPNs composed of poly(N‐isopropylacrylamide‐co‐acrylic acid) [p(NIPAAm‐co‐AAc)] and RGD‐grafted poly(acrylic acid) linear chains [p(AAc)‐g‐RGD] were synthesized with peptide crosslinkers containing a matrix metalloproteinase‐13 (MMP‐13, collagenase‐3) degradable domain. The lower critical solution temperature (LCST) of peptide‐crosslinked p(NIPAAm‐co‐AAc) sIPNs was not influenced by the addition of either linear p(AAc) or peptide‐modified p(AAc) chains (∼34°C) in PBS. Degradation of peptide‐crosslinked hydrogels and sIPNs was enzyme specific and concentration dependent. Exposure of rat calvarial osteoblast (RCO) culture to the degradation products from the peptide‐crosslinked hydrogels did not significantly affect cell viability. Migration of RCOs into the sIPNs was dependent upon the presence of both a cell‐adhesive RGD peptide (Ac‐CGGNGEPRGDTYRAY‐NH 2) and proteolytically‐degradable crosslinks; however, there was greater dependence on the latter. The sIPNs synthesized are versatile materials for assessing cell fate in synthetic ECM constructs in vitro and tissue regeneration in vivo. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alginate hydrogels as synthetic extracellular matrix materials
Rowley, J. A., Madlambayan, G., & Mooney, D. J. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00107-0 · Cited by 2,342
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
Lutolf, M. P., Lauer-Fields, J. L., Schmoekel, H. G., Metters, A. T., Weber, F. E., Fields, G. B., & Hubbell, J. A. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0737381100 · Cited by 1,508
Repair of bone defects using synthetic mimetics of collagenous extracellular matrices
Lutolf, M. P., Weber, F. E., Schmoekel, H. G., Schense, J. C., Kohler, T., Müller, R., & Hubbell, J. A. (2003) · Nature Biotechnology · doi:10.1038/nbt818 · Cited by 850
Cited by
Progress and potential in organoid research
Rossi, G., Manfrin, A., & Lutolf, M. P. (2018) · Nature Reviews Genetics · doi:10.1038/s41576-018-0051-9 · Cited by 1,182
Thermoresponsive Polymers for Biomedical Applications
Ward, M. A., & Georgiou, T. K. (2011) · Polymers · doi:10.3390/polym3031215 · Cited by 1,158
Smart polymeric gels: Redefining the limits of biomedical devices
Chaterji, S., Kwon, I. K., & Park, K. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.018 · Cited by 615
Nicolas, J., Magli, S., Rabbachin, L., Sampaolesi, S., Nicotra, F., & Russo, L. (2020) · Biomacromolecules · doi:10.1021/acs.biomac.0c00045 · Cited by 509
Studies on thermoresponsive polymers: Phase behaviour, drug delivery and biomedical applications
Gandhi, A., Paul, A., Sen, S. O., & Sen, K. K. (2015) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2014.08.010 · Cited by 506
Ulijn, R. V., Bibi, N., Jayawarna, V., Thornton, P. D., Todd, S. J., Mart, R. J., Smith, A. M., & Gough, J. E. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70049-4 · Cited by 484
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467
Enzyme-responsive materials: a new class of smart biomaterials
Ulijn, R. V. (2006) · Journal of Materials Chemistry · doi:10.1039/b601776m · Cited by 467
PNIPAM microgels for biomedical applications: from dispersed particles to 3D assemblies
Guan, Y., & Zhang, Y. (2011) · Soft Matter · doi:10.1039/c0sm01541e · Cited by 459
Surgical adhesives: Systematic review of the main types and development forecast
Duarte, A. P., Coelho, J. F., Bordado, J. C., Cidade, M. T., & Gil, M. H. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.12.003 · Cited by 365
Elucidating the Role of Matrix Stiffness in 3D Cell Migration and Remodeling
Ehrbar, M., Sala, A., Lienemann, P., Ranga, A., Mosiewicz, K., Bittermann, A., Rizzi, S. C., Weber, F. E., & Lutolf, M. P. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2010.11.082 · Cited by 361
Biomaterial Design Strategies for the Treatment of Spinal Cord Injuries
Straley, K. S., Foo, C. W. P., & Heilshorn, S. C. (2010) · Journal of Neurotrauma · doi:10.1089/neu.2009.0948 · Cited by 355
Designer nanoparticles: incorporating size, shape and triggered release into nanoscale drug carriers
Caldorera-Moore, M., Guimard, N., Shi, L., & Roy, K. (2010) · Expert Opinion on Drug Delivery · doi:10.1517/17425240903579971 · Cited by 304
Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions
Barrère, F., Mahmood, T. A., de Groot, K., & van Blitterswijk, C. A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.12.001 · Cited by 303
Fujimoto, K. L., Ma, Z., Nelson, D. M., Hashizume, R., Guan, J., Tobita, K., & Wagner, W. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.055 · Cited by 269
Hydrogels in healthcare: From static to dynamic material microenvironments
Kirschner, C. M., & Anseth, K. S. (2013) · Acta Materialia · doi:10.1016/j.actamat.2012.10.037 · Cited by 255
Madl, C. M., Katz, L. M., & Heilshorn, S. C. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201505329 · Cited by 156
Bioengineering approaches to guide stem cell-based organogenesis
Gjorevski, N., Ranga, A., & Lutolf, M. P. (2014) · Development · doi:10.1242/dev.101048 · Cited by 137
“…behavior do not approximate the porous, fibrillar structure of the natural ECM and its complex mechanics (Mann et al., 2001; Lutolf et al., 2003a; Kim et al., 2005; Peyton et al., 2006; Kloxin et al., 2009; Phelps et al., 2012; Tsurkan et al., 2013; Wylie et al., 2011) D E V E LO P M E N…”
Background
Metadata
- Authors
- Kim, S., Chung, E. H., Gilbert, M., & Healy, K. E.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-07-27
- Volume
- 75A
- Issue
- 1
- Pages
- 73-88
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1988186759
- Cited by
- 129
- References
- 4
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.