CoChat

Characterization of polymeric poly(ϵ‐caprolactone) injectable implant delivery system for the controlled delivery of contraceptive steroids

Dasaratha Dhanaraju, Magharla, Gopinath, Damodaran, Rafiuddin Ahmed, Mohamed, Jayakumar, Rajadas, Vamsadhara, Chandrasekar · 2006 · Journal of Biomedical Materials Research Part A
Cited by 62

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Contraceptive steroids levonorgestrel (LNG) and ethinyl estradiol (EE) have been encapsulated with poly(ϵ‐caprolactone) (PCL) microspheres using a w/o/w double emulsion method. The microspheres prepared were smooth and spherical, with a mean size from 8–25 μm. In vitro release profiles of microspheres showed a trend of increasing initially at the first week, and thereafter the release was sustained. At the end of the seventh week LNG/EE from 1:5 and 1:10 PCL microspheres were 60 and 48%, 52 and 46%, respectively. An in vitro degradation study shows that at the 20th week the microspheres maintained the surface integrity. The PCL microspheres showed a triphasic in vivo release profile with an initial burst effect due to the release of the steroid adsorbed on the microsphere surface, a second sustained release phase due to the steroid diffusion through the pores or channels formed in the polymer matrix, and third phase due to polymer bioerodible. Histological examination of PCL microspheres injected intramuscularly into thigh muscle of a rat showed a minimal inflammatory reaction demonstrating that contraceptive steroid‐loaded microspheres were biocompatible. The level of inflammatory cytokines determined by immunostaining for IL‐1α, the tissue response to formulations at the first week was considered mild, whereas at the end of the 20th week the inflammatory response ceased. Thus, this study helped us to evaluate the feasibility of using these microspheres as a long‐acting biodegradable drug delivery system for contraceptive steroids. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30458

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 62

Metadata

Authors
Dasaratha Dhanaraju, M., Gopinath, D., Rafiuddin Ahmed, M., Jayakumar, R., & Vamsadhara, C.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2005-08-17
Volume
76A
Issue
1
Pages
63-72
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2091822530
Cited by
62
References
4
FWCI
2.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of polymeric poly(ϵ‐caprolactone) injectable implant delivery system for the controlled delivery of contraceptive steroids. https://app.cochat.ai/papers/10.1002/jbm.a.30458
The paper
Dasaratha Dhanaraju, M., Gopinath, D., Rafiuddin Ahmed, M., Jayakumar, R., & Vamsadhara, C. (2006). Characterization of polymeric poly(ϵ‐caprolactone) injectable implant delivery system for the controlled delivery of contraceptive steroids. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30458

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.