Dexamethasone‐functionalized gels induce osteogenic differentiation of encapsulated hMSCs
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Synthetic hydrogels represent highly controlled environments for three‐dimensional culture of human mesenchymal stem cells (hMSCs). Encapsulated hMSCs are presented with a “blank” environment, and this environment can be closely controlled in order to elicit an osteogenic response. In vitro, dexamethasone is an efficient and reliable factor that leads to the osteogenic differentiation of human mesenchymal stem cells (hMSCs). The aim of this work was to develop a dexamethasone‐releasing poly(ethylene glycol) (PEG)‐based hydrogel scaffold to deliver dexamethasone to encapsulated cells in a sustained manner. To accomplish this goal, dexamethasone was covalently linked to a photoreactive mono‐acrylated PEG molecule through a degradable lactide bond, and this molecule was covalently incorporated into the PEG hydrogel during photopolymerization. Over time, hydrolysis of the ester bonds resulted in dexamethasone release from the gel. The biological activity of the released dexamethasone was verified in monolayer cell culture and in three‐dimensional culture (i.e., in the gel) by the ability of hMSCs to express osteogenic genes, including alkaline phosphatase, osteopontin, and core binding factor alpha 1, as measured using real‐time reverse transcription polymerase chain reaction (RT‐PCR). These studies indicate that encapsulated hMSCs are capable of osteogenic differentiation in response to released dexamethasone. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GOVENDER, S., CSIMMA, C., GENANT, H. K., & VALENTIN-OPRAN, A. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200212000-00001 · Cited by 1,308
Cited by
Hydrogels in drug delivery: Progress and challenges
Hoare, T. R., & Kohane, D. S. (2008) · Polymer · doi:10.1016/j.polymer.2008.01.027 · Cited by 3,776
Chitosan-based hydrogels for controlled, localized drug delivery
Bhattarai, N., Gunn, J., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.019 · Cited by 2,451
Cell Encapsulation in Biodegradable Hydrogels for Tissue Engineering Applications
Nicodemus, G. D., & Bryant, S. J. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0332 · Cited by 1,239
PEG Hydrogels for the Controlled Release of Biomolecules in Regenerative Medicine
Lin, C.-C., & Anseth, K. S. (2009) · Pharmaceutical Research · doi:10.1007/s11095-008-9801-2 · Cited by 1,063
Self-citationCell-laden hydrogels for osteochondral and cartilage tissue engineering
Yang, J., Zhang, Y. S., Yue, K., & Khademhosseini, A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.036 · Cited by 652
Kim, J., Kim, I. S., Cho, T. H., Lee, K. B., Hwang, S. J., Tae, G., Noh, I., Lee, S. H., Park, Y., & Sun, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.050 · Cited by 519
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467
Biomaterials for stem cell differentiation
Dawson, E., Mapili, G., Erickson, K., Taqvi, S., & Roy, K. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.037 · Cited by 448
Articular cartilage and osteochondral tissue engineering techniques: Recent advances and challenges
Wei, W., & Dai, H. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.05.011 · Cited by 327
Designing synthetic materials to control stem cell phenotype
Saha, K., Pollock, J. F., Schaffer, D. V., & Healy, K. E. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.05.030 · Cited by 219
A Review of Injectable Polymeric Hydrogel Systems for Application in Bone Tissue Engineering
Kondiah, P., Choonara, Y., Kondiah, P., Marimuthu, T., Kumar, P., Du Toit, L., & Pillay, V. (2016) · Molecules · doi:10.3390/molecules21111580 · Cited by 219
Injectable PLGA based colloidal gels for zero-order dexamethasone release in cranial defects
Wang, Q., Wang, J., Lu, Q., Detamore, M. S., & Berkland, C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.052 · Cited by 183
“Previous reports suggested that sustained delivery of low doses of DEX may enhance osteogenesis; therefore, PLGA colloidal gels containing 5% DEX were selected for in vivo studies [37,38].”
Enabling stem cell therapies through synthetic stem cell–niche engineering
Peerani, R., & Zandstra, P. W. (2010) · Journal of Clinical Investigation · doi:10.1172/jci41158 · Cited by 172
Metadata
- Authors
- Nuttelman, C. R., Tripodi, M. C., & Anseth, K. S.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-11
- Volume
- 76A
- Issue
- 1
- Pages
- 183-195
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2162426041
- Cited by
- 150
- References
- 1
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.