Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 409

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Biodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response

Witte, F., Ulrich, H., Rudert, M., Willbold, E.·2007·Journal of Biomedical Materials Research Part A

Abstract

Current tissue engineering strategies focus on the replacement of pathologically altered tissues by the transplantation of cells in combination with supportive biocompatible scaffolds. Scaffolds for tissue engineering strategies in musculoskeletal research require an appropriate mechanical stability. In recent studies, considerable attention has thus been given to magnesium alloys as biodegradable implants. The aim of this study was to characterize the biocompatibility of magnesium scaffolds by the inflammatory host response. Open porous scaffolds made of the magnesium alloy AZ91D were implanted into the distal femur condyle of rabbits and were compared to autologous bone, which was transplanted into the contralateral condyle in a 3 and 6 months follow‐up group. After 3 months, magnesium scaffolds were already largely degraded and most of the original magnesium alloy has disappeared. Concomitantly, a fibrous capsule enclosed the operation site. Histological analysis revealed that the magnesium scaffolds caused no significant harm to their neighboring tissues. This study shows that even fast degrading magnesium scaffolds show a good biocompatibility and react in vivo with an appropriate inflammatory host response. Magnesium alloy based implants are therefore a very promising approach in the development of mechanically suitable and open porous scaffolds for the replacement of subchondral bone in cartilage tissue engineering. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.31170

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 409

Metadata

Authors
Witte, F., Ulrich, H., Rudert, M., & Willbold, E.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2007-03-27
Volume
81A
Issue
3
Pages
748-756
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2163936468
Cited by
409
References
24
FWCI
8.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response. https://app.cochat.ai/papers/10.1002/jbm.a.31170
The paper
Witte, F., Ulrich, H., Rudert, M., & Willbold, E. (2007). Biodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31170

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.