CoChat

Aligned poly(L‐lactic‐co‐e‐caprolactone) electrospun microfibers and knitted structure: A novel composite scaffold for ligament tissue engineering

Vaquette, Cédryck, Kahn, Cyril, Frochot, Céline, Nouvel, Cécile, Six, Jean‐Luc, De Isla, Natalia, Luo, Li‐Hua, Cooper‐White, Justin, Rahouadj, Rachid, Wang, Xiong · 2010 · Journal of Biomedical Materials Research Part A
Cited by 114

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We developed a novel technique involving knitting and electrospinning to fabricate a composite scaffold for ligament tissue engineering. Knitted structures were coated with poly(L‐lactic‐co‐e‐caprolactone) (PLCL) and then placed onto a rotating cylinder and a PLCL solution was electrospun onto the structure. Highly aligned 2‐μm‐diameter microfibers covered the space between the stitches and adhered to the knitted scaffolds. The stress–strain tensile curves exhibited an initial toe region similar to the tensile behavior of ligaments. Composite scaffolds had an elastic modulus (150 ± 14 MPa) similar to the modulus of human ligaments. Biological evaluation showed that cells proliferated on the composite scaffolds and they spontaneously orientated along the direction of microfiber alignment. The microfiber architecture also induced a high level of extracellular matrix secretion, which was characterized by immunostaining. We found that cells produced collagen type I and type III, two main components found in ligaments. After 14 days of culture, collagen type III started to form a fibrous network. We fabricated a composite scaffold having the mechanical properties of the knitted structure and the morphological properties of the aligned microfibers. It is difficult to seed a highly macroporous structure with cells, however the technique we developed enabled an easy cell seeding due to presence of the microfiber layer. Therefore, these scaffolds presented attractive properties for a future use in bioreactors for ligament tissue engineering. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.32801

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 114

Metadata

Authors
Vaquette, C., Kahn, C., Frochot, C., Nouvel, C., Six, J., De Isla, N., Luo, L., Cooper‐White, J., Rahouadj, R., & Wang, X.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2010-08-02
Volume
94A
Issue
4
Pages
1270-1282
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1977240086
Cited by
114
References
3
FWCI
3.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aligned poly(L‐lactic‐co‐e‐caprolactone) electrospun microfibers and knitted structure: A novel composite scaffold for ligament tissue engineering. https://app.cochat.ai/papers/10.1002/jbm.a.32801
The paper
Vaquette, C., Kahn, C., Frochot, C., Nouvel, C., Six, J., De Isla, N., Luo, L., Cooper‐White, J., Rahouadj, R., & Wang, X. (2010). Aligned poly(L‐lactic‐co‐e‐caprolactone) electrospun microfibers and knitted structure: A novel composite scaffold for ligament tissue engineering. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.32801

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.