CoChat

Comparative analysis of in vitro oxidative degradation of poly(carbonate urethanes) for biostability screening

Dempsey, David K., Carranza, Christopher, Chawla, Chander P., Gray, Patrick, Eoh, Joon H., Cereceres, Stacy, Cosgriff‐Hernandez, Elizabeth M. · 2014 · Journal of Biomedical Materials Research Part A
Cited by 62

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The resistance to oxidation and environmental stress cracking of poly(carbonate urethanes) (PCUs) has generated significant interest as potential replacements of poly(ether urethanes) in medical devices. Several in vitro models have been developed to screen segmented polyurethanes for oxidative stability. High concentrations of reactive oxygen intermediates produced by combining hydrogen peroxide and dissolved cobalt ions has frequently been used to predict long‐term oxidative degradation with short‐term testing. Alternatively, a 3% H 2 O 2 concentration without metal ions is suggested within the ISO 10993‐13 standard to simulate physiological degradation rates. A comparative analysis which evaluates the predictive capabilities of each test method has yet to be completed. To this end, we have utilized both systems to test three commercially available PCUs with low and high soft segment content: Bionate® PCU and Bionate® II PCUs, two materials with different soft segment chemistries, and CarboSil® TSPCU, a thermoplastic silicone PCU. Bulk properties of all PCUs were retained with minor changes in molecular weight and tensile properties indicating surface oxidative degradation in the accelerated system after 36 days. Soft segment loss and surface damage were comparable to previous in vivo data. The 3% H 2 O 2 method exhibited virtually no changes on the surface or in bulk properties after 12 months of treatment despite previous in vivo results. These results indicate the accelerated test method more effectively characterized the oxidative degradation profiles than the 3% H 2 O 2 treatment system. The lack of bulk degradation in the 12‐month study also supports the hydrolytic stability of these PCUs. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 3649–3665, 2014.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.35037

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 62

Metadata

Authors
Dempsey, D. K., Carranza, C., Chawla, C. P., Gray, P., Eoh, J. H., Cereceres, S., & Cosgriff‐Hernandez, E. M.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2013-11-21
Volume
102
Issue
10
Pages
3649-3665
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1528232319
Cited by
62
References
9
FWCI
0.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative analysis of in vitro oxidative degradation of poly(carbonate urethanes) for biostability screening. https://app.cochat.ai/papers/10.1002/jbm.a.35037
The paper
Dempsey, D. K., Carranza, C., Chawla, C. P., Gray, P., Eoh, J. H., Cereceres, S., & Cosgriff‐Hernandez, E. M. (2014). Comparative analysis of in vitro oxidative degradation of poly(carbonate urethanes) for biostability screening. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.35037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.