CoChat

Keratin hydrogel carrier system for simultaneous delivery of exogenous growth factors and muscle progenitor cells

Open access
Tomblyn, Seth, Pettit Kneller, Elizabeth L., Walker, Stephen J., Ellenburg, Mary D., Kowalczewski, Christine J., Van Dyke, Mark, Burnett, Luke, Saul, Justin M. · 2016 · Journal of Biomedical Materials Research Part B: Applied Biomaterials
Cited by 78

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Ideal material characteristics for tissue engineering or regenerative medicine approaches to volumetric muscle loss (VML) include the ability to deliver cells, growth factors, and molecules that support tissue formation from a system with a tunable degradation profile. Two different types of human hair‐derived keratins were tested as options to fulfill these VML design requirements: (1) oxidatively extracted keratin (keratose) characterized by a lack of covalent crosslinking between cysteine residues, and (2) reductively extracted keratin (kerateine) characterized by disulfide crosslinks. Human skeletal muscle myoblasts cultured on coatings of both types of keratin had increased numbers of multinucleated cells compared to collagen or Matrigel TM and adhesion levels greater than collagen. Rheology showed elastic moduli from 10 2 to 10 5 Pa and viscous moduli from 10 1 to 10 4 Pa depending on gel concentration and keratin type. Kerateine and keratose showed differing rates of degradation due to the presence or absence of disulfide crosslinks, which likely contributed to observed differences in release profiles of several growth factors.In vivo testing in a subcutaneous mouse model showed that keratose hydrogels can be used to deliver mouse muscle progenitor cells and growth factors. Histological assessment showed minimal inflammatory responses and an increase in markers of muscle formation. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 864–879, 2016.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.b.33438

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 78

Metadata

Authors
Tomblyn, S., Pettit Kneller, E. L., Walker, S. J., Ellenburg, M. D., Kowalczewski, C. J., Van Dyke, M., Burnett, L., & Saul, J. M.
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2015-05-07
Volume
104
Issue
5
Pages
864-879
ISSN
  • 1552-4973 (ISSN-L)
  • 1552-4981
OpenAlex
W1812221069
Cited by
78
References
8
FWCI
3.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Keratin hydrogel carrier system for simultaneous delivery of exogenous growth factors and muscle progenitor cells. https://app.cochat.ai/papers/10.1002/jbm.b.33438
The paper
Tomblyn, S., Pettit Kneller, E. L., Walker, S. J., Ellenburg, M. D., Kowalczewski, C. J., Van Dyke, M., Burnett, L., & Saul, J. M. (2016). Keratin hydrogel carrier system for simultaneous delivery of exogenous growth factors and muscle progenitor cells. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.33438

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.