3D Assessment of Cortical Bone Porosity and Tissue Mineral Density Using High-Resolution µCT: Effects of Resolution and Threshold Method
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Current micro–computed tomography (µCT) systems allow scanning bone at resolutions capable of three-dimensional (3D) characterization of intracortical vascular porosity and osteocyte lacunae. However, the scanning and reconstruction parameters along with the image segmentation method affect the accuracy of the measurements. In this study, the effects of scanning resolution and image threshold method in quantifying small features of cortical bone (vascular porosity, vascular canal diameter and separation, lacunar porosity and density, and tissue mineral density) were analyzed. Cortical bone from the tibia of Sprague-Dawley rats was scanned at 1-µm and 4-µm resolution, reconstructions were density-calibrated, and volumes of interest were segmented using approaches based on edge-detection or histogram analysis. In 1-µm resolution scans, the osteocyte lacunar spaces could be visualized, and it was possible to separate the lacunar porosity from the vascular porosity. At 4-µm resolution, the vascular porosity and vascular canal diameter were underestimated, and osteocyte lacunae were not effectively detected, whereas the vascular canal separation and tissue mineral density were overestimated compared to 1-µm resolution. Resolution had a much greater effect on the measurements than did threshold method, showing partial volume effects at resolutions coarser than 2 µm in two separate analyses, one of which assessed the effect of resolution on an object of known size with similar architecture to a vascular pore. Although there was little difference when using the edge-detection versus histogram-based threshold approaches, edge-detection was somewhat more effective in delineating canal architecture at finer resolutions (1–2 µm). In addition, use of a high-resolution (1 µm) density-based threshold on lower resolution (4 µm) density-calibrated images was not effective in improving the lower-resolution measurements. In conclusion, if measuring cortical vascular microarchitecture, especially in small animals, a µCT resolution of 1 to 2 µm is appropriate, whereas a resolution of at least 1 µm is necessary when assessing osteocyte lacunar porosity. © 2014 American Society for Bone and Mineral Research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, only the macroporosity of CB can at present be reliably determined using µCT, but not CB's meso-and microporosity, which leads to a systematic underestimation of Ct.Po and Ca.Dm distribution as bone parameters (Cooper et al., 2004;Palacio-Mancheno et al., 2014).”
From Experimental Aqueous Alteration of Cortical Bone Microarchitecture Analyzed by Quantitative Micro-Computed Tomography (2021) · cites this paper as Palacio-Mancheno et al., 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709 · cited 1×
“The specific aims were (1) to investigate the effects of resolution and image thresholding method on 3D measurements of intracortical bone properties, including vascular canal porosity, vascular canal diameter and separation, osteocyte lacunar porosity and density, and TMD; (2) to investigate whether a density‐based t…”
BackgroundStiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652 · cited 1×
“The specific aims were (1) to investigate the effects of resolution and image thresholding method on 3D measurements of intracortical bone properties, including vascular canal porosity, vascular canal diameter and separation, osteocyte lacunar porosity and density, and TMD; (2) to investigate whether a density‐based t…”
Background
Research works printed but not linked: 28
- Martin, 1991, Determinants of the mechanical properties of bones, J Biomech., 24, 79, 10.1016/0021-9290(91)90379-2 · DOI · Paper page
- Wachter, 2001, Prediction of strength of cortical bone in vitro by microcomputed tomography, Clin Biomech., 16, 252, 10.1016/S0268-0033(00)00092-9 · DOI · Paper page
- Schneider, 2007, Ultrastructural properties in cortical bone vary greatly in two inbred strains of mice as assessed by synchrotron light based micro- and nano-CT, J Bone Miner Res., 22, 1557, 10.1359/jbmr.070703 · DOI · Paper page
- Piekarski, 1977, Transport mechanism operating between blood supply and osteocytes in long bones, Nature., 269, 80, 10.1038/269080a0 · DOI · Paper page
- Wang, 1999, Fluid pressure relaxation depends upon osteonal microstructure: modeling an oscillatory bending experiment, J Biomech., 32, 663, 10.1016/S0021-9290(99)00059-7 · DOI
- Goulet, 2008, Influence of vascular porosity on fluid flow and nutrient transport in loaded cortical bone, J Biomech., 41, 2169, 10.1016/j.jbiomech.2008.04.022 · DOI
- Cowin, 1999, J Biomech., 32, 217, 10.1016/S0021-9290(98)00161-4 · DOI · Paper page
- Knothe Tate, 2000, In vivo demonstration of load-induced fluid flow in the rat tibia and its potential implications for processes associated with functional adaptation, J Exp Biol., 203, 2737, 10.1242/jeb.203.18.2737 · DOI · Paper page
- Wang, 2000, Modeling tracer transport in an osteon under cyclic loading, Ann Biomed Eng., 28, 1200, 10.1114/1.1317531 · DOI
- Müller, 2009, Hierarchical microimaging of bone structure and function, Nat Rev Rheumatol., 5, 373, 10.1038/nrrheum.2009.107 · DOI · Paper page
- Cardoso, 2013, Advances in assessment of bone porosity, permeability and interstitial fluid flow, J Biomech., 46, 253, 10.1016/j.jbiomech.2012.10.025 · DOI · Paper page
- Basillais, 2007, Three-dimensional characterization of cortical bone microstructure by microcomputed tomography: validation with ultrasonic and microscopic measurements, J Orthop Sci., 12, 141, 10.1007/s00776-006-1104-z · DOI · Paper page
- Cooper, 2004, Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity, Calcif Tissue Int., 74, 437, 10.1007/s00223-003-0071-z · DOI · Paper page
- Bouxsein, 2010, Guidelines for assessment of bone microstructure in rodents using micro-computed tomography, J Bone Miner Res., 25, 1468, 10.1002/jbmr.141 · DOI · Paper page
- Matsumoto, 2006, Monochromatic synchrotron radiation muCT reveals disuse-mediated canal network rarefaction in cortical bone of growing rat tibiae, J Appl Physiol., 100, 274, 10.1152/japplphysiol.00495.2005 · DOI
- Waarsing, 2004, An improved segmentation method for in-vivo µCT imaging, J Bone Miner Res., 10, 1640, 10.1359/JBMR.040705 · DOI · Paper page
- Rathnayaka, 2011, Effects of image segmentation methods on the accuracy of long bone reconstructions, Med Eng Phys., 33, 226, 10.1016/j.medengphy.2010.10.002 · doi:10.1016/j.medengphy.2010.10.002
- Cooper, 2007, Effect of voxel size on 3D micro-CT analysis of cortical bone porosity, Calcif Tissue Int., 80, 211, 10.1007/s00223-005-0274-6 · DOI · Paper page
- Britz, 2010, 3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia, J Microsc., 240, 32, 10.1111/j.1365-2818.2010.03381.x · DOI · Paper page
- Feldkamp, 1984, Practical cone-beam algorithm, J Opt Soc Am., 1, 612, 10.1364/JOSAA.1.000612 · DOI · Paper page
- Tommasini, 2012, Changes in intracortical microporosities induced by pharmaceutical treatment of osteoporosis as detected by high resolution micro-CT, Bone., 50, 596, 10.1016/j.bone.2011.12.012 · DOI
- Hildebrand, 1997, A new method for the model-independent assessment of thickness in three-dimensionsal images, J Microsc., 185, 67, 10.1046/j.1365-2818.1997.1340694.x · DOI · Paper page
- Gu, 2012, High resolution micro arthrography of hard and soft tissues in a murine model, Osteoarthritis Cartilage., 20, 1011, 10.1016/j.joca.2012.05.004 · doi:10.1016/j.joca.2012.05.004
- Duvall, 2004, Quantitative microcomputed tomography analysis of collateral vessel development after ischemic injury, Am J Physiol Heart Circ Physiol., 287, H302, 10.1152/ajpheart.00928.2003 · DOI · Paper page
- Sietsema, 1995, Animal models of cortical porosity, Bone., 17, 297S, 10.1016/8756-3282(95)00307-Y · DOI
- Schneider, 2009, Simultaneous 3D visualization and quantification of murine bone and bone vasculature using micro-computed tomography and vascular replica, Microsc Res Tech., 72, 690, 10.1002/jemt.20720 · DOI
- Martín-Badosa, 2003, Excised bone structures in mice: imaging at three-dimensional synchrotron radiation micro CT, Radiology., 229, 921, 10.1148/radiol.2293020558 · DOI
- Windhal, 1999, Increased cortical bone mineral content but unchanged trabecular bone mineral density in female ERβ–/– mice, J Clin Invest., 104, 895, 10.1172/JCI6730 · DOI · Paper page
Cited by
Aboulkhair, N. T., Simonelli, M., Parry, L., Ashcroft, I., Tuck, C., & Hague, R. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100578 · Cited by 1,552
Blood and interstitial flow in the hierarchical pore space architecture of bone tissue
Cowin, S. C., & Cardoso, L. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.013 · Cited by 174
“The total volume of the bone fluid vascular porosity is about one half or less than that of the lacunar-canalicular porosity (Ciani et al., 2007, 2008; Cardoso et al., 2013; Palacio-Mancheno et al., 2014).”
Self-citationSharma (2018) · doi:10.1016/j.bone.2018.01.019 · Cited by 70
“5-mm aluminum filter were used, as in our previous work [23].”
MethodKral, A. G., Ziegler, A., Tütken, T., & Geisler, T. (2021) · Frontiers in Earth Science · doi:10.3389/feart.2021.609496 · Cited by 10
Metadata
- Authors
- Palacio-Mancheno, P. E., Larriera, A. I., Doty, S. B., Cardoso, L., & Fritton, S. P.
- Affiliations
- Department of Biomedical EngineeringCity College of New YorkNew YorkNYUSA
- Research DivisionHospital for Special SurgeryNew YorkNYUSA
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-06-15
- Volume
- 29
- Issue
- 1
- Pages
- 142-150
- ISSN
- 0884-0431
- 1523-4681
- Cited by
- 111
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D Assessment of Cortical Bone Porosity and Tissue Mineral Density Using High-Resolution µCT: Effects of Resolution and Threshold Method. https://app.cochat.ai/papers/10.1002/jbmr.2012
- The paper
- Palacio-Mancheno, P. E., Larriera, A. I., Doty, S. B., Cardoso, L., & Fritton, S. P. (2014). 3D Assessment of Cortical Bone Porosity and Tissue Mineral Density Using High-Resolution µCT: Effects of Resolution and Threshold Method. Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.2012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.