In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Trabecular bone architecture is one of the main factors influencing the mechanical behavior of cancellous bone. To assess the three-dimensional trabecular microstructure of intact bones, we introduced the concept of noninvasive bone biopsy, a method to assess and analyze cancellous bone based upon three-dimensional peripheral quantitative computed tomography in vivo (3D-pQCT). The aim of this work was to demonstrate the potential of noninvasive bone biopsies as a basis for structural and mechanical analysis of trabecular bone in the process of rapid bone loss. A group of six healthy young male volunteers was measured to provide data on the reproducibility of structural parameters. Baseline and 1-month follow-up measurements were performed to provide data on short-term precision of the procedure, and three of the controls were reanalyzed within 3–6 months to estimate long-term precision. Prior to structural evaluation, the baseline and follow-up measurements were repositioned three-dimensionally to ensure matching volumes of interest (VOI). Trabecular bone density (TBD) as well as structural indices were analyzed for all measurements. The VOIs were analyzed morphometrically by evaluating bone volume (BV/TV) and trabecular number (Tb.N) based on a direct three-dimensional approach. Trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) were derived from these two indices. The data of the measurements at 1 month to determine the short-term precision was in excellent agreement with the baseline measurements. The results showed that structural parameters can be reproduced in vivo with a coefficient of variation of less than 0.5%. With a typical spread of 4% for the structural indices within the group of healthy volunteers, an intraclass correlation of better than 0.98 was reached. We conclude that high-resolution 3D-pQCT has the potential to detect structural changes in trabecular bone during therapeutic and diagnostic trials. (J Bone Miner Res 1996;11:1745-1750)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Self-citationThe relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603
Trabecular bone pattern factor—a new parameter for simple quantification of bone microarchitecture
Hahn, M., Vogel, M., Pompesius-Kempa, M., & Delling, G. (1992) · Bone · doi:10.1016/8756-3282(92)90078-b · Cited by 540
Age-related changes in vertebral trabecular bone architecture—assessed by a new method
Mosekilde, L. (1988) · Bone · doi:10.1016/8756-3282(88)90038-5 · Cited by 314
Muller, R., Hildebrand, T., & Ruegsegger, P. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/009 · Cited by 245
Self-citationIn vivo, three-dimensional microscopy of trabecular bone
Dr. Kinney, J. H., Lane, N. E., & Haupt, D. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100213 · Cited by 230
Müller, R., Hahn, M., Vogel, M., Delling, G., & Rüegsegger, P. (1996) · Bone · doi:10.1016/8756-3282(95)00489-0 · Cited by 209
Self-citationMajumdar, S., Newitt, D., Jergas, M., Gies, A., Chiu, E., Osman, D., Keltner, J., Keyak, K., & Genant, H. (1995) · Bone · doi:10.1016/s8756-3282(95)00263-4 · Cited by 188
A direct method for fast three‐dimensional serial reconstruction
Odgaard, A., Andersen, K., Melsen, F., & Gundersen, H. J. G. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb03038.x · Cited by 169
Age-Related changes in iliac crest trabecular microanatomic bone structure in man
Compston, J. E., Mellish, R. W. E., & Garrahan, N. J. (1987) · Bone · doi:10.1016/8756-3282(87)90004-4 · Cited by 158
High‐resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo
Jara, H. J., Wehrli, F. W., Chung, H., & Ford, J. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290415 · Cited by 146
Engelke, K., Graeff, W., Meiss, L. A., Hahn, M. P., & Delling, G. (1993) · Investigative Radiology · doi:10.1097/00004424-199304000-00016 · Cited by 139
Analysis of mechanical properties of cancellous bone under conditions of simulated bone atrophy
Müller, R., & Ruegsegger, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00006-1 · Cited by 92
Birkenhäger-Frenkel, D. H., Courpron, P., Hüpscher, E. A., Clermonts, E., Coutinho, M., Schmitz, P. I. M., & Meunier, P. J. (1988) · PubMed · Cited by 80
The Use of Peripheral QCT in the Evaluation of Bone Remodelling
Ruegsegger, P. (1994) · The Endocrinologist · doi:10.1097/00019616-199405000-00004 · Cited by 42
The Mechanical and Remodeling Properties of Trabecular Bone
Goldstein, S. A., Hollister, S. J., Kuhn, J. L., & Kikuchi, N. (1990) · Springer eBooks · doi:10.1007/978-1-4612-3450-0_3 · Cited by 30
Cited by
Boutroy, S., Bouxsein, M. L., Munoz, F., & Delmas, P. D. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1258 · Cited by 1,192
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
Self-citationEngelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Khosla, S., Riggs, B. L., Atkinson, E. J., Oberg, A. L., McDaniel, L. J., Holets, M., Peterson, J. M., & Melton, L. J. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050916 · Cited by 583
Metadata
- Authors
- Dr. Müller, R., Hildebrand, T., Häuselmann, H. J., & Rüegsegger, P.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-11-01
- Volume
- 11
- Issue
- 11
- Pages
- 1745-1750
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W1965166291
- Cited by
- 166
- References
- 18
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.