The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
X‐ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research
Abstract
X‐Ray Reconstruction of Moving Morphology (XROMM) comprises a set of 3D X‐ray motion analysis techniques that merge motion data from in vivo X‐ray videos with skeletal morphology data from bone scans into precise and accurate animations of 3D bones moving in 3D space. XROMM methods include: (1) manual alignment (registration) of bone models to video sequences, i.e., Scientific Rotoscoping; (2) computer vision‐based autoregistration of bone models to biplanar X‐ray videos; and (3) marker‐based registration of bone models to biplanar X‐ray videos. Here, we describe a novel set of X‐ray hardware, software, and workflows for marker‐based XROMM. Refurbished C‐arm fluoroscopes retrofitted with high‐speed video cameras offer a relatively inexpensive X‐ray hardware solution for comparative biomechanics research. Precision for our biplanar C‐arm hardware and analysis software, measured as the standard deviation of pairwise distances between 1 mm tantalum markers embedded in rigid objects, was found to be ±0.046 mm under optimal conditions and ±0.084 mm under actual in vivo recording conditions. Mean error in measurement of a known distance between two beads was within the 0.01 mm fabrication tolerance of the test object, and mean absolute error was 0.037 mm. Animating 3D bone models from sets of marker positions (XROMM animation) makes it possible to study skeletal kinematics in the context of detailed bone morphology. The biplanar fluoroscopy hardware and computational methods described here should make XROMM an accessible and useful addition to the available technologies for studying the form, function, and evolution of vertebrate animals. J. Exp. Zool. 313A:262–279, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
Hedrick, T. L. (2008) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/3/3/034001 · Cited by 1,360
Self-citationHuman movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Determining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
Banks, S. A., & Hodge, W. A. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.495283 · Cited by 596
Dynamic Function of the ACL-reconstructed Knee during Running
Tashman, S., Kolowich, P., Collon, D., Anderson, K., & Anderst, W. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31802bab3e · Cited by 323
Bashore, T. M., Bates, E. R., Berger, P. B., Clark, D. A., Cusma, J. T., Dehmer, G. J., Kern, M. J., Laskey, W. K., O’Laughlin, M. P., Oesterle, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01346-8 · Cited by 320
Tashman, S., & Anderst, W. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1559896 · Cited by 305
Bey, M. J., Zauel, R., Brock, S. K., & Tashman, S. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2206199 · Cited by 300
Hylander, W. L., Johnson, K. R., & Crompton, A. W. (1987) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330720304 · Cited by 268
Chapter 14. Mastication, Food Transport, and Swallowing
Hiiemae, K. M., & Crompton, A. W. (1985) · Functional Vertebrate Morphology · doi:10.4159/harvard.9780674184404.c14 · Cited by 226
You, B.-M., Siy, P., Anderst, W., & Tashman, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929617 · Cited by 200
A model-based method for the reconstruction of total knee replacement kinematics
Zuffi, S., Leardini, A., Catani, F., Fantozzi, S., & Cappello, A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811310 · Cited by 185
Chen, L., Armstrong, C. W., & Raftopoulos, D. D. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90024-8 · Cited by 184
Scientific rotoscoping: a morphology‐based method of 3‐D motion analysis and visualization
Gatesy, S. M., Baier, D. B., Jenkins, F. A., & Dial, K. P. (2010) · Journal of Experimental Zoology Part A: Ecological Genetics and Physiology · doi:10.1002/jez.588 · Cited by 176
Self-citationLi, G., DeFrate, L. E., Park, S. E., Gill, T. J., & Rubash, H. E. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504265577 · Cited by 171
Measuring dynamic in-vivo glenohumeral joint kinematics: Technique and preliminary results
Bey, M. J., Kline, S. K., Zauel, R. R., Lock, T. R., & Kolowich, P. A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.029 · Cited by 159
Hind limb movements of the American alligator (Alligator mississippiensis) and postural grades
Gatesy, S. M. (1991) · Journal of Zoology · doi:10.1111/j.1469-7998.1991.tb03786.x · Cited by 147
Self-citationHiiemäe, K. M. (2000) · Elsevier eBooks · doi:10.1016/b978-012632590-4/50014-9 · Cited by 133
The functional anatomy of the shoulder in the European starling (Sturnus vulgaris)
Dial, K. P., Goslow, G. E., & Jenkins, F. A. (1991) · Journal of Morphology · doi:10.1002/jmor.1052070309 · Cited by 126
A method to estimate in vivo dynamic articular surface interaction
Anderst, W. J., & Tashman, S. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00157-x · Cited by 99
Klein, P. J., & DeHaven, J. J. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80028-x · Cited by 92
Thexton, A. J., Crompton, A. W., & German, R. Z. (1998) · Journal of Experimental Zoology · Cited by 92
Effect of skin movement on the analysis of hindlimb kinematics during treadmill locomotion in rats
Filipe, V. M. D. J., Pereira, J. E., Maltez, L., Maurício, A. C., Couto, P., Melo‐Pinto, P., & Varejão, A. S. P. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.10.006 · Cited by 89
Functional morphology and evolution of aspiration breathing in tetrapods
Brainerd, E. L., & Owerkowicz, T. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.06.003 · Cited by 85
Self-citationKinematics of the quadrate bone during feeding in mallard ducks
Dawson, M. M., Metzger, K. A., Baier, D. B., & Brainerd, E. L. (2011) · Journal of Experimental Biology · doi:10.1242/jeb.047159 · Cited by 73
Self-citationEveraert, D. G., Spaepen, A. J., Wouters, M. J., et al. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90065-5 · Cited by 27
Cited by
The history and impact of digitization and digital data mobilization on biodiversity research
Nelson, G., & Ellis, S. (2019) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2017.0391 · Cited by 304
Heers, A. M., Baier, D. B., Jackson, B. E., & Dial, K. P. (2016) · PLOS ONE · doi:10.1371/journal.pone.0153446 · Cited by 60
Self-citation
Metadata
- Authors
- Brainerd, E. L., Baier, D. B., Gatesy, S. M., Hedrick, T. L., Metzger, K. A., Gilbert, S. L., & Crisco, J. J.
- Venue
- Journal of Experimental Zoology Part A: Ecological Genetics and Physiology
- Publisher
- Wiley
- Published
- 2010-01-21
- Volume
- 313A
- Issue
- 5
- Pages
- 262-279
- ISSN
- 1932-5223 (ISSN-L)
- 1932-5231
- OpenAlex
- W2112924835
- Cited by
- 524
- References
- 27
- FWCI
- 21.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.