The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Practical T2 quantitation for clinical applications
Abstract
Many studies have investigated the use of magnetic resonance relaxation times for tissue characterization. A number have been performed in vivo with clinical whole‐body imagers. Unfortunately, the results have yet to establish the role of quantitative tissue relaxation time measurements in clinical diagnosis. One of the major problems is that the techniques used in many of these studies are error prone, making the results inconclusive. In the present study, the problems associated with clinical T2 measurements were systematically evaluated in an attempt to obtain reliable in vivo quantitation. The authors demonstrate that spoiler gradients are the most effective technique for artifact suppression but that they render ineffective radio‐frequency phase schemes such as the Meiboom‐Gill modification to the Carr‐Purcell sequence to compensate experimental imperfections. The present study results in a more reliable multiecho sequence for T2 measurement. Preliminary clinical results in brain and cervix demonstrate the performance of the new technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Tumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
Numerical Recipes in C: The Art of Scientific Computing
Seiler, M. C., & Seiler, F. A. (1989) · Risk Analysis · doi:10.1111/j.1539-6924.1989.tb01007.x · Cited by 1,346
Levitt, M. H. (1986) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(86)80005-x · Cited by 776
A Fourier method for the analysis of exponential decay curves
Provencher, S. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85660-3 · Cited by 594
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
Bottomley, P. A., Hardy, C. J., Argersinger, R. E., & Allen‐Moore, G. (1987) · Medical Physics · doi:10.1118/1.596111 · Cited by 471
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Book of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 395
Artifacts in Magnetic Resonance Imaging
Bekiesińska‐Figatowska, M. (2015) · Polish Journal of Radiology · doi:10.12659/pjr.892628 · Cited by 349
Variable-rate selective excitation
Conolly, S., Nishimura, D., Macovski, A., & Glover, G. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90131-x · Cited by 321
Compensation for pulse imperfections in NMR spin-echo experiments
Levitt, M. H., & Freeman, R. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90082-2 · Cited by 287
Magnetic resonance imaging and spectroscopy of hepatic iron overload.
Stark, D. D., Moseley, M. E., Bacon, B. R., Moss, A. A., Goldberg, H. I., Bass, N. M., & James, T. L. (1985) · Radiology · doi:10.1148/radiology.154.1.3964933 · Cited by 211
Just, M., & Thelen, M. (1988) · Radiology · doi:10.1148/radiology.169.3.3187000 · Cited by 176
Motion‐insensitive, steady‐state free precession imaging
Zur, Y., Wood, M. L., & Neuringer, L. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160311 · Cited by 173
Errors in T2 estimation using multislice multiple‐echo imaging
Crawley, A. P., & Henkelman, R. M. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040105 · Cited by 171
Self-citationModified Carr-Purcell-Meiboom-Gill sequence for NMR fourier imaging applications
Maudsley, A. A. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90160-5 · Cited by 152
Larsson, H. B. W., Frederiksen, J. L., Kjær, L., Henriksen, O. M., & Olesen, J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070106 · Cited by 129
Practical Implementation and Optimization of One‐shot T1 imaging
Kay, I., & Henkelman, R. M. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220249 · Cited by 89
Self-citationMultiple‐spin‐echo imaging with a 2D Fourier method
Graumann, R., Oppelt, A., & Stetter, E. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030507 · Cited by 84
Uǧurbil, K., Garwood, M., Rath, A. R., & Bendall, M. R. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90133-3 · Cited by 79
Breger, R. K., Wehrli, F. W., Charles, H. C., MacFall, J. R., & Haughton, V. M. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030502 · Cited by 77
A spoiling sequence for suppression of residual transverse magnetization
Wang, H. Z., & Riederer, S. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150202 · Cited by 25
The use of T2 distribution to study tumor extent and heterogeneity in head and neck cancer
Bloch, P., Lenkinski, R. E., Buhle, E. L., Hendrix, R. A., Bryer, M., & McKenna, W. G. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90012-b · Cited by 14
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914
In vivo measurement of T2 distributions and water contents in normal human brain
Whittall, K. P., Mackay, A. L., Graeb, D. A., Nugent, R. A., Li, D. K. B., & Paty, D. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370107 · Cited by 793
The role of magnetic resonance techniques in understanding and managing multiple sclerosis
Miller, D. (1998) · Brain · doi:10.1093/brain/121.1.3 · Cited by 556
Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
Sled, J. G., & Pike, G. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1278 · Cited by 419
Metadata
- Authors
- Poon, C. S., & Henkelman, R. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1992-09
- Volume
- 2
- Issue
- 5
- Pages
- 541-553
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2172129753
- Cited by
- 393
- References
- 26
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.