The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Practical T2 quantitation for clinical applications
Abstract
Many studies have investigated the use of magnetic resonance relaxation times for tissue characterization. A number have been performed in vivo with clinical whole‐body imagers. Unfortunately, the results have yet to establish the role of quantitative tissue relaxation time measurements in clinical diagnosis. One of the major problems is that the techniques used in many of these studies are error prone, making the results inconclusive. In the present study, the problems associated with clinical T2 measurements were systematically evaluated in an attempt to obtain reliable in vivo quantitation. The authors demonstrate that spoiler gradients are the most effective technique for artifact suppression but that they render ineffective radio‐frequency phase schemes such as the Meiboom‐Gill modification to the Carr‐Purcell sequence to compensate experimental imperfections. The present study results in a more reliable multiecho sequence for T2 measurement. Preliminary clinical results in brain and cervix demonstrate the performance of the new technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Tumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
Numerical Recipes in C: The Art of Scientific Computing
Seiler, M. C., & Seiler, F. A. (1989) · Risk Analysis · doi:10.1111/j.1539-6924.1989.tb01007.x · Cited by 1,346
Levitt, M. H. (1986) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(86)80005-x · Cited by 776
A Fourier method for the analysis of exponential decay curves
Provencher, S. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85660-3 · Cited by 594
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
Bottomley, P. A., Hardy, C. J., Argersinger, R. E., & Allen‐Moore, G. (1987) · Medical Physics · doi:10.1118/1.596111 · Cited by 471
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914
In vivo measurement of T2 distributions and water contents in normal human brain
Whittall, K. P., Mackay, A. L., Graeb, D. A., Nugent, R. A., Li, D. K. B., & Paty, D. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370107 · Cited by 793
The role of magnetic resonance techniques in understanding and managing multiple sclerosis
Miller, D. (1998) · Brain · doi:10.1093/brain/121.1.3 · Cited by 556
Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
Sled, J. G., & Pike, G. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1278 · Cited by 419
Mosher, T. J., Dardzinski, B. J., & Smith, M. B. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja15259 · Cited by 390
Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379
Insights into brain microstructure from the T2 distribution
MacKay, A., Laule, C., Vavasour, I., Bjarnason, T., Kolind, S., & Mädler, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.037 · Cited by 347
Magnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
Spatial variation in cartilage T2 of the knee
Smith, H. E., Mosher, T. J., Dardzinski, B. J., Collins, B. G., Collins, C. M., Yang, Q. X., Schmithorst, V. J., & Smith, M. B. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1150 · Cited by 288
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Rapid whole cerebrum myelin water imaging using a 3D GRASE sequence
Prasloski, T., Rauscher, A., MacKay, A. L., Hodgson, M., Vavasour, I. M., Laule, C., & Mädler, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.064 · Cited by 268
Applications of stimulated echo correction to multicomponent T2 analysis
Prasloski, T., Mädler, B., Xiang, Q., MacKay, A., & Jones, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23157 · Cited by 253
Is diffusion anisotropy an accurate monitor of myelination?
Mädler, B., Drabycz, S. A., Kolind, S. H., Whittall, K. P., & MacKay, A. L. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.047 · Cited by 227
A pathology–MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain
Moore, G. R. W., Leung, E., MacKay, A. L., Vavasour, I. M., Whittall, K. P., Cover, K. S., Li, D. K. B., Hashimoto, S. A., Oger, J., Sprinkle, T. J., et al. (2000) · Neurology · doi:10.1212/wnl.55.10.1506 · Cited by 185
Characterizing White Matter Damage in Rat Spinal Cord with Quantitative MRI and Histology
Kozlowski, P., Raj, D., Liu, J., Lam, C., Yung, A. C., & Tetzlaff, W. (2008) · Journal of Neurotrauma · doi:10.1089/neu.2007.0462 · Cited by 129
Kastman, E. K., Willette, A. A., Coe, C. L., Bendlin, B. B., Kosmatka, K. J., McLaren, D. G., Xu, G., Canu, E., Field, A. S., Alexander, A. L., et al. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.0835-10.2010 · Cited by 85
On the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Myelin Water Fraction in Human Cervical Spinal Cord In Vivo
Wu, Y., Alexander, A. L., Fleming, J. O., Duncan, I. D., & Field, A. S. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200603000-00026 · Cited by 51
Kolind, S. H., Laule, C., Vavasour, I. M., Li, D. K. B., Traboulsee, A. L., Mädler, B., Moore, G. R. W., & MacKay, A. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.033 · Cited by 44
“T2 relaxation was measured using a single-slice multi-echo experiment, consisting of a 90° slice selective pulse followed by 48 composite block pulses (90°x–180°y–90°x) flanked by sliceselective crusher gradient pulses designed to minimize stimulated echoes (Poon and Henkelman, 1992) (TR=2120–3800 ms, echo spacing for…”
MethodKastman, E. K., Willette, A. A., Coe, C. L., Bendlin, B. B., Kosmatka, K. J., McLaren, D. G., Xu, G., Canu, E., Field, A. S., Alexander, A. L., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2553-12.2012 · Cited by 40
“The transverse relaxation rate, T2, was calculated by first performing log transformations of the voxel signal intensity data for all 4 TEs and then linear-fitting the slope according to the monoexponential Spin Echo signal intensity equation (Poon and Henkelman, 1992).”
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Metadata
- Authors
- Poon, C. S., & Henkelman, R. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1992-09
- Volume
- 2
- Issue
- 5
- Pages
- 541-553
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2172129753
- Cited by
- 393
- References
- 26
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.