Abstract
The effect of the oxygen inhalation on relaxation times was evaluated in various tissues, including the myocardium, liver, spleen, skeletal muscle, subcutaneous fat, bone marrow, and arterial blood, with a [1 H]MR system. Statistically significant decrease of T1 relaxation times was observed in the myocardium, spleen, and arterial blood after inhalation of 100% oxygen, whereas no significant change was observed in liver, skeletal muscle, subcutaneous fat, or bone marrow. The T2 relaxation time of these tissues did not differ significantly between before and after inhalation of the oxygen. These results indicate that [1 H]MRI can be used to evaluate changes with oxygen inhalation and that the effect of the oxygen inhalation on T1 relaxation time is different among various tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
(1992) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(92)90560-d · Cited by 1,040
Echo‐planar time course MRI of cat brain oxygenation changes
Turner, R., Bihan, D. L., Moonen, C. T. W., Despres, D., & Frank, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220117 · Cited by 421
TEXTBOOK OF RESPIRATORY MEDICINE
Klayton, R. J. (1995) · Military Medicine · doi:10.1093/milmed/160.1.a7a · Cited by 404
Ventilation/Blood Flow and Gas Exchange.
(1978) · Annals of Internal Medicine · doi:10.7326/0003-4819-88-6-852_8 · Cited by 303
The Magnetic Properties and Structure of the Hemochromogens and Related Substances
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.3.159 · Cited by 231
Magnetic resonance imaging of stationary blood: A review
Brooks, R. A., & Di Chiro, G. (1987) · Medical Physics · doi:10.1118/1.595994 · Cited by 137
Mason, R. P., Shukla, H., & Antich, P. P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290304 · Cited by 116
Methodology for the measurement and analysis of relaxation times in proton imaging
MacFall, J. R., Wehrli, F. W., Breger, R. K., & Johnson, G. A. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90022-1 · Cited by 103
Ganz, W., DONOSO, R., Marcus, H. S., & Swan, H. J. C. (1972) · Circulation · doi:10.1161/01.cir.45.4.763 · Cited by 100
Oxygen-sensitive 19F NMR imaging of the vascular system in vivo
Fishman, J. E., Joseph, P. M., Floyd, T. F., MUKHERJI, B., & Sloviter, H. A. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90005-1 · Cited by 64
Fishman, J. E., Joseph, P. M., Carvlin, M. J., Saadi-Elmandjra, M., MUKHERJI, B., & Sloviter, H. A. (1989) · Investigative Radiology · doi:10.1097/00004424-198901000-00014 · Cited by 62
Circulation through special regions
Satchell, G. H. (1991) · Cambridge University Press eBooks · doi:10.1017/cbo9780511983719.007 · Cited by 53
Imaging oxygen tension in liver and spleen by 19F NMR
Holland, S. K., Kennan, R. P., Schaub, M. M., D'Angelo, M. J., & Gore, J. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290405 · Cited by 44
Nöth, U., Morrissey, S., Deichmann, R., Adolf, H., Schwarzbauer, C., Lutz, J., & Haase, A. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340513 · Cited by 43
Wendland, M. F., Saeed, M., Lauerma, K., de Crespigny, A. J., Moseley, M. E., & Higgins, C. B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290220 · Cited by 41
Oxygen tension mapping with F‐19 echo‐planar MR imaging of sequestered perfluorocarbon
Barker, B. R., Mason, R. P., Bansal, N., & Peshock, R. M. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040414 · Cited by 40
Effect of Oxygen Tension on NMR Spin-Lattice Relaxation Rate of Blood in vivo
TRIPATHI, A., Bydder, G. M., HUGHES, J. M. B., Pennock, J. M., Goatcher, A., Orr, J. S., Steiner, R. E., & Greenspan, R. H. (1984) · Investigative Radiology · doi:10.1097/00004424-198405000-00004 · Cited by 26
Cited by
Imaging tumour hypoxia with oxygen-enhanced MRI and BOLD MRI
O'Connor, J. P. B., Robinson, S. P., & Waterton, J. C. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20180642 · Cited by 169
Blockley, N. P., Griffeth, V. E. M., Simon, A. B., & Buxton, R. B. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2847 · Cited by 162
Metadata
- Authors
- Tadamura, E., Hatabu, H., Li, W., Prasad, P. V., & Edelman, R. R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 7
- Issue
- 1
- Pages
- 220-225
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2014092468
- Cited by
- 178
- References
- 24
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.