The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Imaging artifacts at 3.0T
Abstract
Clinical MRI at a field strength of 3.0T is finding increasing use. However, along with the advantages of 3.0T, such as increased SNR, there can be drawbacks, including increased levels of imaging artifacts. Although every imaging artifact observed at 3.0T can also be present at 1.5T, the intensity level is often higher at 3.0T and thus the artifact is more objectionable. This review describes some of the imaging artifacts that are commonly observed with 3.0T imaging, and their root causes. When possible, countermeasures that reduce the artifact level are described. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils
Gruetter, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290613 · Cited by 870
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Principles and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.2.1830343 · Cited by 517
Menon, R. S., Ogawa, S., Hu, X., Strupp, J. P., Anderson, P., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330323 · Cited by 421
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Rose, A., & Biberman, L. (1975) · Physics Today · doi:10.1063/1.3069240 · Cited by 378
High frequency volume coils for clinical NMR imaging and spectroscopy
Vaughan, J. T., Hetherington, H. P., Otu, J. O., Pan, J. W., & Pohost, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320209 · Cited by 374
Artifacts in Magnetic Resonance Imaging
Bekiesińska‐Figatowska, M. (2015) · Polish Journal of Radiology · doi:10.12659/pjr.892628 · Cited by 349
Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325
MR image artifacts from periodic motion
Wood, M. L., & Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595782 · Cited by 302
Imaging at high magnetic fields: initial experiences at 4 T.
Uǧurbil, K., Garwood, M., Ellermann, J., Hendrich, K. S., Hinke, R. M., Hu, X. P., Kim, S. G., Menon, R. S., Merkle, H., & Ogawa, S. (1993) · PubMed · Cited by 282
Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz
Collins, C. M., Liu, W., Wang, J., Gruetter, R., Vaughan, J. T., Ugurbil, K., & Smith, M. B. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20041 · Cited by 275
Collins, C. M., & Smith, M. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1091 · Cited by 260
Rose, A. (1970) · Applied Solid State Physics · doi:10.1007/978-1-4684-1854-5_4 · Cited by 251
Central brightening due to constructive interference with, without, and despite dielectric resonance
Collins, C. M., Liu, W., Schreiber, W., Yang, Q. X., & Smith, M. B. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20245 · Cited by 245
Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting
Cho, Z. H., Kim, D. J., & Kim, Y. K. (1988) · Medical Physics · doi:10.1118/1.596162 · Cited by 217
Single‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1282 · Cited by 206
Self-citationRegularized higher‐order in vivo shimming
Kim, D., Adalsteinsson, E., Glover, G. H., & Spielman, D. M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10267 · Cited by 200
Eckstein, F., Charles, H. C., Buck, R. J., Kraus, V. B., Remmers, A. E., Hudelmaier, M., Wirth, W., & Evelhoch, J. L. (2005) · Arthritis & Rheumatism · doi:10.1002/art.21348 · Cited by 197
Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL
Rakow‐Penner, R., Daniel, B., Yu, H., Sawyer‐Glover, A., & Glover, G. H. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20469 · Cited by 196
Fischer, H. W., Rinck, P. A., van Haverbeke, Y., & Muller, R. N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160212 · Cited by 176
Rapid three‐dimensional T1‐weighted MR imaging with the MP‐RAGE sequence
Mugler, J. P., & Brookeman, J. R. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010509 · Cited by 174
Arnold, J. B., Liow, J.-S., Schaper, K. A., Stern, J. J., Sled, J. G., Shattuck, D. W., Worth, A. J., Cohen, M. S., Leahy, R. M., Mazziotta, J. C., et al. (2001) · NeuroImage · doi:10.1006/nimg.2001.0756 · Cited by 172
Estimating radiofrequency power deposition in body NMR imaging
Bottomley, P. A., Redington, R. W., Edelstein, W. A., & Schenck, J. F. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020404 · Cited by 171
MR imaging at high magnetic fields
Takahashi, M., Uematsu, H., & Hatabu, H. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00331-5 · Cited by 139
MRI of Prostate Cancer at 1.5 and 3.0 T: Comparison of Image Quality in Tumor Detection and Staging
Beyersdorff, D., Taymoorian, K., Knösel, T., Schnorr, D., Felix, R., Hamm, B., & Bruhn, H. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1584 · Cited by 134
Compensation for surface coil sensitivity variation in magnetic resonance imaging
Narayana, P. A., Brey, W. W., Kulkarni, M. V., & Sievenpiper, C. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90401-8 · Cited by 131
MR imaging of articular cartilage at 1.5 T and 3.0 T: Comparison of SPGR and SSFP sequences
Kornaat, P. R., Reeder, S. B., Koo, S., Brittain, J. H., Yu, H., Andriacchi, T. P., & Gold, G. E. (2005) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2004.12.008 · Cited by 131
Al-Kwifi, O. S., Emery, D. J., & Wilman, A. H. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00486-1 · Cited by 128
Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography.
Gibbs, G. F., Huston, J., Bernstein, M. A., et al. (2004) · PubMed · Cited by 125
Self-citationGreenman, R. L., Shirosky, J. E., Mulkern, R. V., & Rofsky, N. M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10316 · Cited by 125
Kantarci, K., Reynolds, G., Petersen, R. C., Boeve, B. F., Knopman, D. S., Edland, S. D., Smith, G. E., Ivnik, R. J., Tangalos, E. G., & Jack, C. R. (2003) · PubMed · Cited by 123
In vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnet
Barfuss, H., Fischer, H., Hentschel, D., Ladebeck, R., Oppelt, A., Wittig, R., Duerr, W., & Oppelt, R. (1990) · NMR in Biomedicine · doi:10.1002/nbm.1940030106 · Cited by 119
Advances in High-Field Magnetic Resonance Imaging
Hu, X. P., & Norris, D. G. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140017 · Cited by 112
Advantages and pitfalls in 3T MR brain imaging: a pictorial review.
Schmitz, B., Aschoff, A. J., Hoffmann, M. H. K., & Grön, G. (2005) · PubMed Central · Cited by 109
Reduction of blurring in view angle tilting MRI
Butts, K., Pauly, J. M., & Gold, G. E. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20375 · Cited by 108
Artifacts in musculoskeletal magnetic resonance imaging: identification and correction
Peh, W., & Chan, J. H. M. (2001) · Skeletal Radiology · doi:10.1007/s002560100341 · Cited by 106
Kuhl, C. K., Textor, J., Gieseke, J., Falkenhausen, M. V., Gernert, S., Urbach, H., & Schild, H. H. (2005) · Radiology · doi:10.1148/radiol.2342031323 · Cited by 100
Krautmacher, C., Willinek, W. A., Tschampa, H. J., et al. (2005) · Radiology · doi:10.1148/radiol.2373041672 · Cited by 97
Single‐shot halfk‐space high‐resolution gradient‐recalled EPI for fMRI at 3 tesla
Jesmanowicz, A., Bandettini, P. A., & Hyde, J. S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400517 · Cited by 96
3 Tesla-MRT: Der Erfolg h�herer Feldst�rken
Schmitt, F., Grosu, D., Mohr, C., Purdy, D. E., Salem, K., Scott, K. T., & Stoeckel, B. (2004) · Der Radiologe · doi:10.1007/s00117-003-1000-x · Cited by 88
Evaluation of multiple sclerosis by 1H spectroscopic imaging at 4.1 T
Pan, J. W., Hetherington, H. P., Vaughan, J. T., Mitchell, G. W., Pohost, G. M., & Whitaker, J. N. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360113 · Cited by 73
Accurate T1 determination from inversion recovery images: Application to human brain at 4 Tesla
Kim, S., Hu, X. P., & Uǧurbil, K. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310414 · Cited by 66
Michaely, H. J., Nael, K., Schoenberg, S. O., Laub, G. A., Reiser, M. F., Finn, J. P., & Ruehm, S. G. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000192023.96494.af · Cited by 59
MR imaging of epilepsy: State of the art at 1.5 T and potential of 3 T
Briellmann, R. S., Pell, G. S., Wellard, R. M., Mitchell, L. A., Abbott, D. F., & Jackson, G. D. (2003) · Epileptic Disorders · doi:10.1684/j.1950-6945.2003.tb00521.x · Cited by 57
Practical consideration for 3T imaging
Lin, W., An, H., Chen, Y., Nicholas, P., Zhai, G., Gerig, G., Gilmore, J. H., & Bullitt, E. (2003) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(03)00068-0 · Cited by 54
MR imaging contrast in human brain tissue: assessment and optimization at 4 T.
Duewell, S., Wolff, S. D., Wen, H.-Z., Balaban, R. S., & Jezzard, P. (1996) · Radiology · doi:10.1148/radiology.199.3.8638005 · Cited by 50
High-resolution T2-reversed magnetic resonance imaging on a high magnetic field system
Fujii, Y., Nakayama, N., & Nakada, T. (1998) · Journal of neurosurgery · doi:10.3171/jns.1998.89.3.0492 · Cited by 49
Uematsu, H., Takahashi, M., Dougherty, L., & Hatabu, H. (2004) · Clinical Imaging · doi:10.1016/s0899-7071(03)00151-7 · Cited by 48
Three-Dimensional Contrast-Enhanced MR Angiography of the Thoraco-Abdominal Vessels
Nael, K., Laub, G. A., & Finn, J. P. (2005) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2005.03.010 · Cited by 33
Gaa, J., Weidauer, S., Requardt, M., et al. (2004) · Acta Radiologica · doi:10.1080/02841850410004229 · Cited by 32
Efficacy of Contrast Medium Use for Neuroimaging at 3.0 T
Fischbach, F., Bruhn, H., Pech, M., Neumann, F., Ricke, J., Felix, R., & Hoffmann, K. (2005) · Journal of Computer Assisted Tomography · doi:10.1097/01.rct.0000166636.85918.3d · Cited by 20
Cited by
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
A Hitchhiker's Guide to Functional Magnetic Resonance Imaging
Soares, J. M., Magalhães, R., Moreira, P. S., Sousa, A., Ganz, E., Sampaio, A., Alves, V., Marques, P., & Sousa, N. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00515 · Cited by 272
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Structural brain development: A review of methodological approaches and best practices
(2017) · doi:10.1016/j.dcn.2017.11.008 · Cited by 124
Chung, A. W., Seunarine, K. K., & Clark, C. A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23328 · Cited by 63
Metadata
- Authors
- Bernstein, M. A., Huston, J., & Ward, H. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2006-09-06
- Volume
- 24
- Issue
- 4
- Pages
- 735-746
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1999960294
- Cited by
- 255
- References
- 62
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.