CoChat

Hyperpolarized 3He and 129Xe MRI: Differences in asthma before bronchodilation

Open access
Svenningsen, Sarah, Kirby, Miranda, Starr, Danielle, Leary, Del, Wheatley, Andrew, Maksym, Geoffrey N., McCormack, David G., Parraga, Grace · 2013 · Journal of Magnetic Resonance Imaging
Cited by 165

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Purpose: To compare hyperpolarized helium‐3 (3 He) and xenon‐129 (129 Xe) MRI in asthmatics before and after salbutamol inhalation. Materials and Methods: Seven asthmatics provided written informed consent and underwent spirometry, plethysmography, and MRI before and after salbutamol inhalation. 3 He and 129 Xe ventilation defect percent (VDP) and ventilation coefficient of variation (COV) were measured. To characterize the airways spatially related to ventilation defects, wall area percent (WA%) and lumen area (LA) were evaluated for two subjects who had thoracic x‐ray computed tomography (CT) acquired 1 year before MRI. Results: Before salbutamol inhalation, 129 Xe VDP (8 ± 5%) was significantly greater than 3 He VDP (6 ± 5%, P = 0.003). Post‐salbutamol, there was a significant improvement in both 129 Xe (5 ± 4%, P < 0.0001) and 3 He (4 ± 3%, P = 0.001) VDP, and the improvement in 129 Xe VDP was significantly greater (P = 0.008). 129 Xe MRI COV (Pre: 0.309 ± 0.028, Post: 0.296 ± 0.036) was significantly greater than 3 He MRI COV (Pre: 0.282 ± 0.018, Post: 0.269 ± 0.024), pre‐ (P < 0.0001) and post‐salbutamol (P < 0.0001) and the decrease in COV post‐salbutamol was significant (129 Xe, P = 0.002; 3 He, P < 0.0001). For a single asthmatic, a sub‐segmental 129 Xe MRI ventilation defect that was visible only before salbutamol inhalation but not visible using 3 He MRI was spatially related to a remodeled fourth generation sub‐segmental airway (WA% = 78%, LA = 2.9 mm 2). Conclusion: In asthma, hyperpolarized 129 Xe MRI may help reveal ventilation abnormalities before bronchodilation that are not observed using hyperpolarized 3 He MRI. J. Magn. Reson. Imaging 2013;38:1521–1530. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.24111

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Svenningsen, S., Kirby, M., Starr, D., Leary, D., Wheatley, A., Maksym, G. N., McCormack, D. G., & Parraga, G.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2013-04-15
Volume
38
Issue
6
Pages
1521-1530
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2080039982
Cited by
165
References
44
FWCI
6.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.