CoChat

Quantitative mapping of glycoprotein micro‐heterogeneity and macro‐heterogeneity: an evaluation of mass spectrometry signal strengths using synthetic peptides and glycopeptides

Open access
Stavenhagen, Kathrin, Hinneburg, Hannes, Thaysen‐Andersen, Morten, Hartmann, Laura, Silva, Daniel Varón, Fuchser, Jens, Kaspar, Stephanie, Rapp, Erdmann, Seeberger, Peter H., Kolarich, Daniel · 2013 · Journal of Mass Spectrometry
Cited by 153

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Mass spectrometry (MS) is used to quantify the relative distribution of glycans attached to particular protein glycosylation sites (micro‐heterogeneity) and evaluate the molar site occupancy (macro‐heterogeneity) in glycoproteomics. However, the accuracy of MS for such quantitative measurements remains to be clarified. As a key step towards this goal, a panel of related tryptic peptides with and without complex, biantennary, disialylated N‐glycans was chemically synthesised by solid‐phase peptide synthesis. Peptides mimicking those resulting from enzymatic deglycosylation using PNGase F/A and endo D/F/H were synthetically produced, carrying aspartic acid and N‐acetylglucosamine‐linked asparagine residues, respectively, at the glycosylation site. The MS ionisation/detection strengths of these pure, well‐defined and quantified compounds were investigated using various MS ionisation techniques and mass analysers (ESI‐IT, ESI‐Q‐TOF, MALDI‐TOF, ESI/MALDI‐FT‐ICR‐MS). Depending on the ion source/mass analyser, glycopeptides carrying complex‐type N‐glycans exhibited clearly lower signal strengths (10–50% of an unglycosylated peptide) when equimolar amounts were analysed. Less ionisation/detection bias was observed when the glycopeptides were analysed by nano‐ESI and medium‐pressure MALDI. The position of the glycosylation site within the tryptic peptides also influenced the signal response, in particular if detected as singly or doubly charged signals. This is the first study to systematically and quantitatively address and determine MS glycopeptide ionisation/detection strengths to evaluate glycoprotein micro‐heterogeneity and macro‐heterogeneity by label‐free approaches. These data form a much needed knowledge base for accurate quantitative glycoproteomics. Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.3210

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 46

  1. 10.1093/glycob/12.4.43R · DOI · Paper page
  2. 10.1038/nrm3383 · DOI · Paper page
  3. 10.1016/S0304-4165(99)00165-8 · DOI · Paper page
  4. 10.1038/srep00090 · DOI · Paper page
  5. Varki A., 2009, Essentials of Glycobiology
  6. 10.1016/j.cbpa.2011.12.006 · DOI
  7. 10.1038/nprot.2012.062 · DOI · Paper page
  8. 10.1021/pr900956x · DOI
  9. Sumer‐Bayraktar Z., 2011, N‐glycans modulate the function of human corticosteroid‐binding globulin, Molecular & Cellular Proteomics: MCP, 10, 10.1074/mcp.M111.009100 · DOI · Paper page
  10. 10.1016/j.jchromb.2006.09.041 · DOI · Paper page
  11. 10.1002/elps.200410424 · DOI
  12. 10.1021/ac0006019 · DOI · Paper page
  13. 10.1021/ac990298f · DOI · Paper page
  14. 10.1586/epr.11.24 · doi:10.1586/epr.11.24
  15. 10.4155/bio.09.117 · DOI
  16. 10.1021/ac970624w · DOI
  17. 10.1146/annurev-arplant-042809-112132 · DOI · Paper page
  18. 10.1002/pmic.200800775 · doi:10.1002/pmic.200800775
  19. 10.1002/anie.200804735 · DOI
  20. 10.1002/anie.200250572 · doi:10.1002/anie.200250572
  21. 10.1016/S0304-4165(96)00118-3 · DOI · Paper page
  22. 10.1002/chem.200305115 · DOI · Paper page
  23. 10.1016/j.tetlet.2009.08.106 · doi:10.1016/j.tetlet.2009.08.106
  24. Cohen S. A., 2003, Amino acid analysis using pre‐column derivatization with 6‐aminoquinolyl‐N‐hydroxysuccinimidyl carbamate. Analysis of hydrolyzed proteins and electroblotted samples, Methods Mol. Biol., 211, 143
  25. 10.1016/0003-2697(92)90164-3 · DOI
  26. Lewis J. K., 2006, Encyclopedia of Analytical Chemistry
  27. 10.1021/ac100530w · DOI · Paper page
  28. 10.1002/(SICI)1098-2787(1999)18:6<349::AID-MAS1>3.0.CO;2-H · DOI · Paper page
  29. 10.1002/pmic.201100498 · DOI
  30. 10.1002/pmic.200401248 · DOI
  31. 10.1201/b12965-10 · DOI
  32. 10.1021/ac9024413 · DOI · Paper page
  33. 10.1016/j.jchromb.2009.01.003 · DOI · Paper page
  34. 10.1002/pmic.200700720 · DOI
  35. 10.1021/ac2003888 · DOI
  36. 10.1002/rcm.1416 · doi:10.1002/rcm.1416
  37. 10.1002/jssc.200900850 · DOI
  38. 10.1021/ac900231w · DOI
  39. 10.1002/pmic.200700968 · DOI · Paper page
  40. 10.1016/0009-8981(94)90121-X · DOI
  41. 10.1074/jbc.M309804200 · DOI · Paper page
  42. 10.1074/jbc.M109.088401 · DOI · Paper page
  43. 10.1002/bit.22348 · DOI · Paper page
  44. 10.1021/pr2011268 · DOI · Paper page
  45. 10.1016/j.cell.2010.04.012 · DOI · Paper page
  46. 10.1002/pmic.201100300 · DOI

Cited by

See all 153

Metadata

Authors
Stavenhagen, K., Hinneburg, H., Thaysen‐Andersen, M., Hartmann, L., Silva, D. V., Fuchser, J., Kaspar, S., Rapp, E., Seeberger, P. H., & Kolarich, D.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2013-05-22
Volume
48
Issue
6
Pages
627-639
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W2003001989
Cited by
153
References
3
FWCI
7.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.