CoChat

Affinity selection–mass spectrometry for the discovery of pharmacologically active compounds from combinatorial libraries and natural products

Muchiri, Ruth N., van Breemen, Richard B. · 2021 · Journal of Mass Spectrometry
Cited by 41

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Invented to address the high‐throughput screening (HTS) demands of combinatorial chemistry, affinity selection–mass spectrometry (AS‐MS) utilizes binding interactions between ligands and receptors to isolate pharmacologically active compounds from mixtures of small molecules and then relies on the selectivity, sensitivity, and speed of mass spectrometry to identify them. No radiolabels, fluorophores, or chromophores are required. Although many variations of AS‐MS have been devised, three approaches have emerged as the most flexible, productive, and popular, and they differ primarily in how ligand–receptor complexes are separated from nonbinding compounds in the mixture. These are pulsed ultrafiltration (PUF) AS‐MS, size exclusion chromatography (SEC) AS‐MS, and magnetic microbead affinity selection screening (MagMASS). PUF and SEC AS‐MS are solution‐phase screening approaches, and MagMASS uses receptors immobilized on magnetic microbeads. Because pools of compounds are screened using AS‐MS, each containing hundreds to thousands of potential ligands, hundreds of thousands of compounds can be screened per day. AS‐MS is also compatible with complex mixtures of chemically diverse natural products in extracts of botanicals and fungi and microbial cultures, which often contain fluorophores and chromophores that can interfere with convention HTS. Unlike conventional HTS, AS‐MS may be used to discover ligands binding to allosteric as well as orthosteric receptor sites, and AS‐MS has been useful for discovering ligands to targets that are not easily incorporated into conventional HTS such as membrane‐bound receptors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.4647

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 41

Metadata

Authors
Muchiri, R. N., & van Breemen, R. B.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2020-09-21
Volume
56
Issue
5
Pages
e4647-e4647
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W3081149612
Cited by
41
References
6
FWCI
2.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Affinity selection–mass spectrometry for the discovery of pharmacologically active compounds from combinatorial libraries and natural products. https://app.cochat.ai/papers/10.1002/jms.4647
The paper
Muchiri, R. N., & van Breemen, R. B. (2021). Affinity selection–mass spectrometry for the discovery of pharmacologically active compounds from combinatorial libraries and natural products. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.4647

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.