Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Magnetic resonance tracking of transplanted bone marrow and embryonic stem cells labeled by iron oxide nanoparticles in rat brain and spinal cord

Jendelová, Pavla, Herynek, Vít, Urdzíková, Lucia, Glogarová, Kateřina, Kroupová, Jana, Andersson, Benita, Bryja, Vítězslav, Burian, Martin, Hájek, Milan, Syková, Eva · 2004 · Journal of Neuroscience Research

Abstract

Nuclear magnetic resonance (MR) imaging provides a noninvasive method for studying the fate of transplanted cells in vivo. We studied, in animals with a cortical photochemical lesion or with a balloon‐induced spinal cord compression lesion, the fate of implanted rat bone marrow stromal cells (MSCs) and mouse embryonic stem cells (ESCs) labeled with superparamagnetic iron oxide nanoparticles (Endorem). MSCs were colabeled with bromodeoxyuridine (BrdU), and ESCs were transfected with pEGFP‐C1 (eGFP ESCs). Cells were either grafted intracerebrally into the contralateral hemisphere of the adult rat brain or injected intravenously. In vivo MR imaging was used to track their fate; Prussian blue staining and electron microscopy confirmed the presence of iron oxide nanoparticles inside the cells. During the first week postimplantation, grafted cells migrated to the lesion site and populated the border zone of the lesion. Less than 3% of MSCs differentiated into neurons and none into astrocytes; 5% of eGFP ESCs differentiated into neurons, whereas 70% of eGFP ESCs became astrocytes. The implanted cells were visible on MR images as a hypointense area at the injection site, in the corpus callosum and in the lesion. The hypointense signal persisted for more than 50 days. The presence of GFP‐positive or BrdU‐positive and nanoparticle‐labeled cells was confirmed by histological staining. Our study demonstrates that both grafted MSCs and eGFP ESCs labeled with a contrast agent based on iron oxide nanoparticles migrate into the injured CNS. Iron oxide nanoparticles can therefore be used as a marker for the long‐term noninvasive MR tracking of implanted stem cells. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jnr.20041

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 300

Metadata

Authors
Jendelová, P., Herynek, V., Urdzíková, L., Glogarová, K., Kroupová, J., Andersson, B., Bryja, V., Burian, M., Hájek, M., & Syková, E.
Venue
Journal of Neuroscience Research
Publisher
Wiley
Published
2004-03-08
Volume
76
Issue
2
Pages
232-243
ISSN
  • 0360-4012 (ISSN-L)
  • 1097-4547
OpenAlex
W1972456044
Cited by
300
References
37
FWCI
10.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic resonance tracking of transplanted bone marrow and embryonic stem cells labeled by iron oxide nanoparticles in rat brain and spinal cord. https://app.cochat.ai/papers/10.1002/jnr.20041
The paper
Jendelová, P., Herynek, V., Urdzíková, L., Glogarová, K., Kroupová, J., Andersson, B., Bryja, V., Burian, M., Hájek, M., & Syková, E. (2004). Magnetic resonance tracking of transplanted bone marrow and embryonic stem cells labeled by iron oxide nanoparticles in rat brain and spinal cord. Journal of Neuroscience Research. https://doi.org/10.1002/jnr.20041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.