Human monocyte response to particulate biomaterials generated in vivo and in vitro
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
We studied the ability of four clinically relevant particle species to stimulate human peripheral blood monocytes to release bone‐resorbing agents, including interleukin‐1 (both interleukin‐1α and interleukin‐1β), interleukin‐6, and prostaglandin E 2. The species studied were titanium‐6%aluminum‐4%vanadium (TiAlV), commercially pure titanium, fabricated ultrahigh molecular weight polyethylene, and polyethylene retrieved from interfacial membranes of failed uncemented total hip arthroplasties. For all species, the mean size was less than 1 μm. Human peripheral blood monocytes were challenged with these particles in a uniform manner on the basis of surface area. Phorbol 12‐myristate acetate, zymosan, and nonphagocytosable titanium particles served as controls. Stimulation of human monocytes is a function of the composition and concentration of particles. In this study. TiAlV particles appeared to be the most competent to elicit the synthesis and release of inflammatory mediators. Particles of commercially pure titanium and of fabricated ultrahigh molecular weight polyethylene also could induce the release of various cellular mediators, albeit at a lower level, whereas the particles of polyethylene retrieved from interfacial membranes were less stimulatory in these short‐term in vitro experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IL-6 is produced by osteoblasts and induces bone resorption.
Ishimi, Y., Miyaura, C., Jin, C. H., Akatsu, T., Abe, E., Nakamura, Y., Yamaguchi, A., Yoshiki, S., Matsuda, T., Hirano, T., et al. (1990) · The Journal of Immunology · doi:10.4049/jimmunol.145.10.3297 · Cited by 1,128
Production of hybridoma growth factor by human monocytes
Aarden, L. A., De Groot, E. R., Schaap, O. L., & Lansdorp, P. M. (1987) · European Journal of Immunology · doi:10.1002/eji.1830171004 · Cited by 1,092
Schindler, R., Mancilla, J., Endres, S., Ghorbani, R., Clark, S., & Dinarello, C. (1990) · Blood · doi:10.1182/blood.v75.1.40.40 · Cited by 1,012
Schmalzried, T. P., Jasty, M., & Harris, W. H. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274060-00006 · Cited by 989
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
Reactions of the articular capsule to wear products of artificial joint prostheses
Willert, H. ‐., & Semlitsch, M. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110202 · Cited by 822
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_20 · Cited by 783
Goldstein, I. M., Roos, D., Kaplan, H. B., & Weissmann, G. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108191 · Cited by 746
Landegren, U. (1984) · Journal of Immunological Methods · doi:10.1016/0022-1759(84)90477-0 · Cited by 652
Agins, H. J., Alcock, N. W., Bansal, M., Salvati, E. A., Wilson, P. D., Pellicci, P. M., & Bullough, P. G. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870030-00005 · Cited by 496
Cited by
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering
Brydone, A. S., Meek, D., & Maclaine, S. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim770 · Cited by 456
Jacobs, J. J., Roebuck, K. A., Archibeck, M., Hallab, N. J., & Glant, T. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200112000-00008 · Cited by 367
Self-citationGreen, T. R., Fisher, J., Matthews, J. B., Stone, M. H., & Ingham, E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200009)53:5<490::aid-jbm7>3.0.co;2-7 · Cited by 310
The Basic Science of Periprosthetic Osteolysis*†
ARCHIBECK, M. J., JACOBS, J. J., ROEBUCK, K. A., & GLANT, T. T. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200010000-00014 · Cited by 236
Self-citationInhibition of Wear Debris Mediated Osteolysis in a Canine Total Hip Arthroplasty Model
Shanbhag, A. S., Hasselman, C. T., & Rubash, H. E. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199711000-00005 · Cited by 216
Self-citationSpinal Implant Debris-Induced Osteolysis
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003) · Spine · doi:10.1097/00007632-200310151-00006 · Cited by 201
Self-citationMeasurement and removal of adherent endotoxin from titanium particles and implant surfaces
Ragab, A. A., Van De Motter, R., Lavish, S. A., Goldberg, V. M., Ninomiya, J. T., Carlin, C. R., & Greenfield, E. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170603 · Cited by 191
“Although these particles are prepared by a commercial milling process and are therefore not authentic orthopaedic wear particles, many previous studies have examined biological responses to them (4,6,7,16,18,19,28,31,45).”
BackgroundHUBER, M., REINISCH, G., TRETTENHAHN, G., ZWEYMULLER, K., & LINTNER, F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.032 · Cited by 180
Trindade, M. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00181-2 · Cited by 80
Metadata
- Authors
- Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 13
- Issue
- 5
- Pages
- 792-801
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2068562565
- Cited by
- 252
- References
- 35
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.