The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Influence of Array Interspacing on the Force Required for Successful Microneedle Skin Penetration: Theoretical and Practical Approaches
Open accessAbstract
Insertion behaviour of microneedle (MN) arrays depends upon the mechanical properties of the skin and, MN geometry and distribution in an array. In addressing this issue, this paper studies MN array insertion mechanism into skin and provides a simple quantitative basis to relate the insertion force with distance between two MNs. The presented framework is based on drawing an analogy between a beam on an elastic foundation and mechanism of needle insertion, where insertion force is separated into different components. A theoretical analysis indicates that insertion force decreases as interspacing increases. For a specified skin type, insertion force decreased from 0.029 to 0.028 N/MN when interspacing at MN tip was increased from 50 μm (350 μm at MN base) to 150 μm (450 μm at MN base). However, dependence of insertion force seems to decrease as the interspacing is increased beyond 150 μm. To assess the validity of the proposed model, a series of experiments was carried out to determine the force required for skin insertion of MN. Experiments performed at insertion speed of 0.5 and 1.0 mm/s yielded insertion force values of 0.030 and 0.0216 N, respectively, for 30 μm interspacing at MN base (330 μm interspacing at tip) and 0.028 and 0.0214 N, respectively, for 600 μm interspacing at MN base (900 μm interspacing at tip). Results from theoretical analysis and finite element modelling agree well with experimental results, which show MN interspacing only begins to affect insertion force at low interspacing (<150 μm interspacing at MN base). This model provides a framework for optimising MN devices, and should aid development of suitable application method and determination of force for reliable insertion into skin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P. (1936) · UCLA Biblioteca de Ingenieria Civil · Cited by 7,592
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Knops, R. J., & Wilkes, E. W. (1973) · Mechanics of Solids · doi:10.1007/978-3-642-69569-8_2 · Cited by 5,165
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Mechanical properties and Young's modulus of human skin in vivo
Agache, P. G., Monneur, C., Leveque, J. L., & De Rigal, J. (1980) · Archives of Dermatological Research · doi:10.1007/bf00406415 · Cited by 741
Optimizing Microneedle Arrays to Increase Skin Permeability for Transdermal Drug Delivery
Al‐Qallaf, B., & Das, D. B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2009.04083.x · Cited by 554
Self-citationNeedle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518
Age-related mechanical properties of human skin: An in vivo study
Escoffier, C., de Rigal, J., Rochefort, A., Vasselet, R., Léveˆque, J.-L., & Agache, P. G. (1989) · Journal of Investigative Dermatology · doi:10.1016/0022-202x(89)90058-4 · Cited by 493
Donnelly, R. F., Majithiya, R., Singh, T. R. R., Morrow, D. I. J., Garland, M. J., Demir, Y. K., Migalska, K., Ryan, E., Gillen, D., Scott, C. J., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0169-8 · Cited by 417
Self-citationHolbrook, K. A., & Odland, G. F. (1974) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12701670 · Cited by 353
Age-related changes in the elastic properties and thickness of human facial skin
TAKEMA, Y., YORIMOTO, Y., KAWAI, M., & IMOKAWA, G. (1994) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1994.tb04975.x · Cited by 341
Egawa, M., Hirao, T., & Takahashi, M. (2007) · Acta Dermato-Venereologica · doi:10.2340/00015555-0183 · Cited by 336
Rosen, J., Hannaford, B., MacFarlane, M. P., & Sinanan, M. N. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.790498 · Cited by 326
Donnelly, R. F., Garland, M. J., Morrow, D. I. J., Migalska, K., Singh, T. R. R., Majithiya, R., & Woolfson, A. D. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.08.008 · Cited by 307
Self-citationCUA, A. B., WILHELM, K.-P., & MAIBACH, H. I. (2006) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1990.tb01452.x · Cited by 265
Gambichler, T., Matip, R., Moussa, G., Altmeyer, P., & Hoffmann, K. (2006) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2006.09.008 · Cited by 239
Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method
Verbaan, F. J., Bal, S. M., van den Berg, D. J., Dijksman, J. A., van Hecke, M., Verpoorten, H., van den Berg, A., Luttge, R., & Bouwstra, J. A. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.02.009 · Cited by 233
WIDERA, G., JOHNSON, J., KIM, L., LIBIRAN, L., NYAM, K., DADDONA, P., & CORMIER, M. (2006) · Vaccine · doi:10.1016/j.vaccine.2005.09.049 · Cited by 208
Modeling of needle insertion forces for robot-assisted percutaneous therapy
Simone, C., & Okamura, A. M. (2003) · Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) · doi:10.1109/robot.2002.1014848 · Cited by 200
Measuring microelastic properties of stratum corneum
Yuan, Y., & Verma, R. (2006) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2005.12.013 · Cited by 191
Davidson, A., Al-Qallaf, B., & Das, D. B. (2008) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2008.06.002 · Cited by 174
Self-citationA computational skin model: fold and wrinkle formation
Magnenat‐Thalmann, N., Kalra, P. K., Lévêque, J. L., Bazin, R., Batisse, D., & Querleux, B. (2002) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2002.806097 · Cited by 160
Bioengineering of the skin : skin surface imaging and analysis
Wilhelm, K. (1997) · CRC Press eBooks · Cited by 143
Humbert, P. G., Maibach, H. I., Fanian, F., & Agache, P. G. (2011) · Medical Entomology and Zoology · Cited by 139
OH, J., PARK, H., Do, K., Han, M. S., Hyun, D.-H., Kim, C.-G., Kim, C.-G., Lee, S., Hwang, S., & Shin, S. H. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.02.009 · Cited by 138
Crichton, M. L., Ansaldo, A. B., Chen, X., Prow, T. W., Fernando, G. J. P., & Kendall, M. A. F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.022 · Cited by 129
Geometrical effects in mechanical characterizing of microneedle for biomedical applications
Aggarwal, P., & Johnston, C. R. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.04.024 · Cited by 122
Sex‐ and site‐dependent variations in the thickness and mechanical properties of human skin in vivo
Diridollou, S., Black, D., Lagarde, J. M., Gall, Y., Berson, M., Vabre, V., Patat, F., & Vaillant, L. (2000) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2000.00037.x · Cited by 99
Kuwazuru, O., Saothong, J., & Yoshikawa, N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.001 · Cited by 90
Leddy, H. A., Haider, M. A., & Guilak, F. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.075283 · Cited by 89
Optimization of square microneedle arrays for increasing drug permeability in skin
Al‐Qallaf, B., & Das, D. B. (2008) · Chemical Engineering Science · doi:10.1016/j.ces.2008.02.007 · Cited by 76
Self-citationOlatunji, O., Das, D. B., & Nassehi, V. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22736 · Cited by 64
Self-citationMINIATURE PIG AS AN ANIMAL MODEL TO STUDY PHOTOAGING*
Fourtanier, A. M., & Berrebi, C. (1989) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1989.tb02908.x · Cited by 61
Al‐Qallaf, B., & Das, D. B. (2008) · Journal of drug targeting · doi:10.1080/10611860802472370 · Cited by 60
Self-citationModelling transdermal delivery of high molecular weight drugs from microneedle systems
Al‐Qallaf, B., Das, D. B., Mori, D., & Cui, Z. (2007) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2007.0003 · Cited by 53
Self-citationRelationship between Structure of Finger Tissue and Location of Tactile Receptors.
Maéno, T., Kobayashi, K., & YAMAZAKI, N. (1997) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.63.881 · Cited by 52
Transdermal drug delivery by coated microneedles: geometry effects on drug concentration in blood
Al‐Qallaf, B., Das, D. B., & Davidson, A. G. (2009) · Asia-Pacific Journal of Chemical Engineering · doi:10.1002/apj.353 · Cited by 40
Self-citationWoolfson, A. D., McCafferty, D. F., McCallion, C. R., McAdams, E. T., & Anderson, J. M. (1995) · Journal of Applied Polymer Science · doi:10.1002/app.1995.070580810 · Cited by 27
Transdermal Drug Delivery by Microneedles: Does Skin Metabolism Matter?
Al‐Qallaf, B., Mori, D., Olatunji, L., Das, D. B., & Cui, Z. (2009) · International Journal of Chemical Reactor Engineering · doi:10.2202/1542-6580.1907 · Cited by 26
Self-citation
Cited by
Transdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530
Makvandi, P., Kirkby, M., Hutton, A. R. J., Shabani, M., Yiu, C. K. Y., Baghbantaraghdari, Z., Jamaledin, R., Carlotti, M., Mazzolai, B., Mattoli, V., et al. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00611-9 · Cited by 455
Self-citationScarless wound healing programmed by core-shell microneedles
Zhang, Y., Wang, S., Yang, Y., Zhao, S., You, J., Wang, J., Cai, J., Wang, H., Wang, J., Zhang, W., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-39129-6 · Cited by 340
Cardiac cell–integrated microneedle patch for treating myocardial infarction
Tang, J., Wang, J., Huang, K., Ye, Y., Su, T., Qiao, L., Hensley, M. T., Caranasos, T. G., Zhang, J., Gu, Z., et al. (2018) · Science Advances · doi:10.1126/sciadv.aat9365 · Cited by 316
Core–Shell Microneedle Gel for Self-Regulated Insulin Delivery
Wang, J., Ye, Y., Yu, J., Kahkoska, A. R., Zhang, X., Wang, C., Sun, W., Corder, R. D., Chen, Z., Khan, S. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08152 · Cited by 299
Metadata
- Authors
- Olatunji, O., Das, D. B., Garland, M. J., Belaid, L., & Donnelly, R. F.
- Venue
- Journal of Pharmaceutical Sciences
- Publisher
- Elsevier BV
- Published
- 2013-04
- Volume
- 102
- Issue
- 4
- Pages
- 1209-1221
- ISSN
- 0022-3549 (ISSN-L)
- OpenAlex
- W2038815967
- Cited by
- 277
- References
- 44
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.