Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Transdermal drug delivery by coated microneedles: Geometry effects on effective skin thickness and drug permeability

Open access
Davidson, Adam, Al-Qallaf, Barrak, Das, Diganta Bhusan·2008·Chemical Engineering Research and Design

Abstract

Abstract Although transdermal drug delivery has been used for about three decades, the range of therapeutics that are administered this way is limited by the barrier function of the stratum corneum (the top layer of skin). Microneedle arrays have been shown to increase the drug permeability in skin by several orders of magnitude by bypassing the stratum corneum. This can potentially allow the transdermal delivery of many medicaments including large macromolecules that typically cannot diffuse through the skin. This paper addresses the use of microneedles coated with a drug solution film. In particular, we identify how the geometries of various microneedles affect the drug permeability in skin. Effective skin permeability is calculated for a range of microneedle shapes and dimensions in order to identify the most efficient geometry. To calculate effective permeability ( P eff ), the effective skin thickness ( H eff ) is calculated. These are then plotted for insulin as a model drug to see how various microneedle parameters affect the profiles of both H eff and P eff . It is found that the depth of penetration from the microneedle array is the most important factor in determining P eff , followed by the microneedle spacings. Other parameters such as microneedle diameter and coating depth are less significant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cherd.2008.06.002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 174

Metadata

Authors
Davidson, A., Al-Qallaf, B., & Das, D. B.
Venue
Chemical Engineering Research and Design
Publisher
Elsevier BV
Published
2008-11
Volume
86
Issue
11
Pages
1196-1206
ISSN
0263-8762 (ISSN-L)
OpenAlex
W1965758660
Cited by
174
References
1
FWCI
4.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transdermal drug delivery by coated microneedles: Geometry effects on effective skin thickness and drug permeability. https://app.cochat.ai/papers/10.1016/j.cherd.2008.06.002
The paper
Davidson, A., Al-Qallaf, B., & Das, D. B. (2008). Transdermal drug delivery by coated microneedles: Geometry effects on effective skin thickness and drug permeability. Chemical Engineering Research and Design. https://doi.org/10.1016/j.cherd.2008.06.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.