Diffusion and Swelling Measurements in Pharmaceutical Powder Compacts Using Terahertz Pulsed Imaging
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Tablet dissolution is strongly affected by swelling and solvent penetration into its matrix. A terahertz-pulsed imaging (TPI) technique, in reflection mode, is introduced as a new tool to measure one-dimensional swelling and solvent ingress in flat-faced pharmaceutical compacts exposed to dissolution medium from one face of the tablet. The technique was demonstrated on three tableting excipients: hydroxypropylmethyl cellulose (HPMC), Eudragit RSPO, and lactose. Upon contact with water, HPMC initially shrinks to up to 13% of its original thickness before undergoing expansion. HPMC and lactose were shown to expand to up to 20% and 47% of their original size in 24 h and 13 min, respectively, whereas Eudragit does not undergo dimensional change. The TPI technique was used to measure the ingress of water into HPMC tablets over a period of 24 h and it was observed that water penetrates into the tablet by anomalous diffusion. X-ray microtomography was used to measure tablet porosity alongside helium pycnometry and was linked to the results obtained by TPI. Our results highlight a new application area of TPI in the pharmaceutical sciences that could be of interest in the development and quality testing of advanced drug delivery systems as well as immediate release formulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633 · cited 2×
“(1) The reference waveforms used in these experiments refer to a reflection from the dry tablet before the tablet is exposed to water.”
BackgroundEvaluation of rapidly disintegrating tablets prepared by a direct compression method
Bi, Y. X., Sunada, H., Yonezawa, Y., & Danjo, K. (1999) · Drug Development and Industrial Pharmacy · doi:10.1081/ddc-100102211 · Cited by 269
Zeitler, J. A., Shen, Y., Baker, C., Taday, P. F., Pepper, M., & Rades, T. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20789 · Cited by 208
Self-citationOn the strong and narrow absorption signature in lactose at 0.53THz
Brown, E. R., Bjarnason, J. E., Fedor, A. M., & Korter, T. M. (2007) · Applied Physics Letters · doi:10.1063/1.2437107 · Cited by 124
Bawuah, P., Pierotic Mendia, A., Silfsten, P., Pääkkönen, P., Ervasti, T., Ketolainen, J., Zeitler, J. A., & Peiponen, K.-E. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.02.011 · Cited by 70
Self-citation
Cited by
A review of disintegration mechanisms and measurement techniques
Markl, D., & Zeitler, J. A. (2017) · Pharmaceutical Research · doi:10.1007/s11095-017-2129-z · Cited by 439
“[77] demonstrated that using this technique it is possible to analyse liquid ingress and tablet swelling quan-”
BackgroundMethodInfluentialSelf-citationCharacterisation of pore structures of pharmaceutical tablets: A review
Markl, D., Strobel, A., Schlossnikl, R., Bøtker, J., Bawuah, P., Ridgway, C., Rantanen, J., Rades, T., Gane, P., Peiponen, K.-E., et al. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.01.017 · Cited by 154
Self-citationMarkl, D., Sauerwein, J., Goodwin, D. J., van den Ban, S., & Zeitler, J. A. (2017) · Pharmaceutical Research · doi:10.1007/s11095-017-2108-4 · Cited by 73
“pacts that exhibit a high porosity [23, 24].”
A Fast and Non-destructive Terahertz Dissolution Assay for Immediate Release Tablets
Bawuah, P., Markl, D., Turner, A., Evans, M., Portieri, A., Farrell, D., Lucas, R., Anderson, A., Goodwin, D. J., & Zeitler, J. A. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2020.11.041 · Cited by 45
Self-citationFast and non-destructive pore structure analysis using terahertz time-domain spectroscopy
Markl, D., Bawuah, P., Ridgway, C., van den Ban, S., Goodwin, D. J., Ketolainen, J., Gane, P., Peiponen, K.-E., & Zeitler, J. A. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.029 · Cited by 42
Self-citation
Metadata
- Authors
- Yassin, S., Su, K., Lin, H., Gladden, L. F., & Axel Zeitler, J.
- Venue
- Journal of Pharmaceutical Sciences
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 104
- Issue
- 5
- Pages
- 1658-1667
- ISSN
- 0022-3549 (ISSN-L)
- OpenAlex
- W2110557656
- Cited by
- 68
- References
- 5
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion and Swelling Measurements in Pharmaceutical Powder Compacts Using Terahertz Pulsed Imaging. https://app.cochat.ai/papers/10.1002/jps.24376
- The paper
- Yassin, S., Su, K., Lin, H., Gladden, L. F., & Axel Zeitler, J. (2015). Diffusion and Swelling Measurements in Pharmaceutical Powder Compacts Using Terahertz Pulsed Imaging. Journal of Pharmaceutical Sciences. https://doi.org/10.1002/jps.24376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.