CoChat

Improved methods for fluorescence background subtraction from Raman spectra

Open access
Cadusch, P. J., Hlaing, M. M., Wade, S. A., McArthur, S. L., Stoddart, P. R. · 2013 · Journal of Raman Spectroscopy
Cited by 142

The DOI matches its Crossref record.

Abstract

Raman spectroscopy has attracted interest as a non‐invasive optical technique to study the composition and structure of a wide range of materials at the microscopic level. The intrinsic fluorescence background can be orders of magnitude stronger than the Raman scattering, and so, background removal is one of the foremost challenges for quantitative analysis of Raman spectra in many samples. A range of methods anchored in instrumental and computational programming approaches have been proposed for removing fluorescence background signals. An enhanced adaptive weighting scheme for automated fluorescence removal is reported, applicable to both polynomial fitting and penalized least squares approaches. Analysis of the background fitting results for ensembles of simulated spectra suggests that the method is robust and reliable and can significantly improve the background fit over the range of signal, shot noise and background parameters tested, while reducing the subjective nature of the process. The method was also illustrated by application to experimental data generated from aqueous solutions of bulk protein fibrinogen mixed with dextran. Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jrs.4371

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 23

  1. 10.1002/lpor.200810012 · DOI
  2. 10.1021/ac049753k · DOI · Paper page
  3. 10.1039/B406524G · DOI
  4. 10.1016/j.chemolab.2004.10.003 · DOI · Paper page
  5. 10.1366/0003702053945985 · DOI · Paper page
  6. 10.1366/0003702924125122 · DOI · Paper page
  7. 10.1366/0003702924125555 · DOI
  8. 10.1002/(SICI)1097-4555(199903)30:3<169::AID-JRS365>3.0.CO;2-P · doi:10.1002/(sici)1097-4555(199903)30:3<169::aid-jrs365>3.0.co;2-p
  9. 10.1366/0003702054280757 · DOI
  10. 10.1364/OE.18.020049 · DOI · Paper page
  11. 10.1002/jrs.784 · DOI · Paper page
  12. 10.1002/jrs.1510 · DOI
  13. 10.1366/000370203322102979 · doi:10.1366/000370203322102979
  14. 10.1016/j.vibspec.2012.03.009 · DOI
  15. 10.1021/ac0010072 · DOI
  16. 10.1366/0003702001951066 · doi:10.1366/0003702001951066
  17. 10.1366/0003702953964039 · DOI · Paper page
  18. 10.1111/j.1751-1097.1998.tb03262.x · DOI · Paper page
  19. 10.1366/000370207782597003 · DOI · Paper page
  20. 10.1366/0003702971940134 · DOI
  21. 10.1366/0003702011953289 · doi:10.1366/0003702011953289
  22. 10.1002/jrs.2500 · DOI · Paper page
  23. 10.1366/000370203322554518 · DOI · Paper page

Cited by

Metadata

Authors
Cadusch, P. J., Hlaing, M. M., Wade, S. A., McArthur, S. L., & Stoddart, P. R.
Venue
Journal of Raman Spectroscopy
Publisher
Wiley
Published
2013-09-02
Volume
44
Issue
11
Pages
1587-1595
ISSN
  • 0377-0486 (ISSN-L)
  • 1097-4555
OpenAlex
W2144903443
Cited by
142
References
0
FWCI
3.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.